linear reconstruction
Recently Published Documents


TOTAL DOCUMENTS

98
(FIVE YEARS 10)

H-INDEX

18
(FIVE YEARS 2)

2021 ◽  
Vol 60 (06) ◽  
Author(s):  
Guodong Zhou ◽  
Yanqiu Li ◽  
Ke Liu

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 807
Author(s):  
Samuel R. White ◽  
Kieran T. Wood ◽  
Peter G. Martin ◽  
Dean T. Connor ◽  
Thomas B. Scott ◽  
...  

Radiation mapping, through the detection of ionising gamma-ray emissions, is an important technique used across the nuclear industry to characterise environments over a range of length scales. In complex scenarios, the precise localisation and activity of radiological sources becomes difficult to determine due to the inability to directly image gamma photon emissions. This is a result of the potentially unknown number of sources combined with uncertainties associated with the source-detector separation—causing an apparent ‘blurring’ of the as-detected radiation field relative to the true distribution. Accurate delimitation of distinct sources is important for decommissioning, waste processing, and homeland security. Therefore, methods for estimating the precise, ‘true’ solution from radiation mapping measurements are required. Herein is presented a computational method of enhanced radiological source localisation from scanning survey measurements conducted with a robotic arm. The procedure uses an experimentally derived Detector Response Function (DRF) to perform a randomised-Kaczmarz deconvolution from robotically acquired radiation field measurements. The performance of the process is assessed on radiation maps obtained from a series of emulated waste processing scenarios. The results demonstrate a Projective Linear Reconstruction (PLR) algorithm can successfully locate a series of point sources to within 2 cm of the true locations, corresponding to resolution enhancements of between 5× and 10×.


Mathematics ◽  
2020 ◽  
Vol 9 (1) ◽  
pp. 69
Author(s):  
Omer Musa ◽  
Guoping Huang ◽  
Mingsheng Wang

Adaptive order weighted essentially non-oscillatory scheme (WENO-AO(5,3)) has increased the computational cost and complexity of the classic fifth-order WENO scheme by introducing a complicated smoothness indicator for fifth-order linear reconstruction. This smoothness indicator is based on convex combination of three third-order linear reconstructions and fifth-order linear reconstruction. Therefore, this paper proposes a new simple smoothness indicator for fifth-order linear reconstruction. The devised smoothness indicator linearly combines the existing smoothness indicators of third-order linear reconstructions, which reduces the complexity of that of WENO-AO(5,3) scheme. Then WENO-AO(5,3) scheme is modified to WENO-O scheme with new and simple formulation. Numerical experiments in 1-D and 2-D were run to demonstrate the accuracy and efficacy of the proposed scheme in which WENO-O scheme was compared with original WENO-AO(5,3) scheme along with WENO-AO-N, WENO-Z, and WENO-JS schemes. The results reveal that the proposed WENO-O scheme is not only comparable to the original scheme in terms of accuracy and efficacy but also decreases its computational cost and complexity.


Author(s):  
A.V. NEMENKO ◽  
M.M. NIKITIN

We consider the method of non-contact measurement of the displacements of a controlled structure using its scanning by radiation of the optical range with fixing the point of reception of reflected radiation. We show that when coordinating the position of the receiving and transmitting blocks, a high sensitivity of the method is achieved. For the practical application of the method, the installation of a receiving and transmitting unit and a mirror technological site at a controlled facility is required.


2019 ◽  
Vol 79 ◽  
pp. 106451 ◽  
Author(s):  
Jianping Gou ◽  
Jun Song ◽  
Weihua Ou ◽  
Shaoning Zeng ◽  
Yunhao Yuan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document