hybrid tracer
Recently Published Documents


TOTAL DOCUMENTS

19
(FIVE YEARS 7)

H-INDEX

4
(FIVE YEARS 0)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Nuria Sánchez-Izquierdo ◽  
Sergi Vidal-Sicart ◽  
Francisco Campos ◽  
Aureli Torné ◽  
Martina Aida Angeles ◽  
...  

Abstract Purpose Indocyanine green (ICG) is frequently used for the detection of the sentinel lymph node (SLN) in gynecology, but it carries the loss of the presurgical SLN mapping provided by [99mTc]-based colloids. Hybrid tracers such as ICG-[99mTc]Tc-albumin nanocolloid combine the benefits of both components. The aim of this study was to evaluate the feasibility and applicability of this hybrid tracer injected by transvaginal ultrasound-guided myometrial injection of radiotracer (TUMIR) approach in the detection of SLNs in patients with intermediate- and high-risk EC. Methods Fifty-two patients with intermediate- and high-risk EC underwent SLN biopsy after injection of a hybrid tracer using the TUMIR approach, followed by pelvic and paraaortic lymphadenectomy. SLNs were detected preoperatively by lymphoscintigraphic study and intraoperatively by gamma probe and near-infrared (NIR) optical laparoscopic camera. Results Preoperative lymphatic drainage was obtained in 69% and intraoperative detection in 71.4% of patients. A total of 146 SLNs (4.17 SLNs/patient) were biopsied. Pelvic bilateral detection was observed in 57% of the women and paraaortic drainage in 34% of the patients. The radioactive component allowed the detection of SLN in 97.1% of the patients, while the fluorescent component detected 80%. In more than 17% of the patients with intraoperative detection, SLNs were detected only by the radioactive signal. Lymph node metastasis was identified in 14.3% of patients submitted to SLNB. The sensitivity and negative predictive value for metastatic involvement were 100%. Conclusion TUMIR injection of a hybrid tracer in patients with intermediate- and high-risk EC combines the benefits of the radiotracer and the fluorescence methods with a single tracer. The method increases the paraaortic detection rate and allows a potential increase in SLN detection. Notwithstanding, based on our findings, the radioactive component of the hybrid tracer cannot be obviated.


2021 ◽  
Author(s):  
Nuria Sánchez Izquierdo ◽  
Sergi Vidal-Sicart ◽  
Francisco Campos ◽  
Aureli Torné ◽  
Martina Aida Angeles ◽  
...  

Abstract Purpose: Indocyanine green (ICG) is frequently used for the detection of the sentinel lymph node (SLN) in gynecology, but it carries the loss of the presurgical SLN mapping provided by [99mTc]-based colloids. Hybrid tracers such as ICG-[99mTc] Tc-albumin nanocolloid combine the benefits of both components. The aim of this study was to evaluate the feasibility and applicability of this hybrid tracer injected by transvaginal ultrasound-guided myometrial injection of radiotracer (TUMIR) approach in the detection of SLNs in patients with intermediate- and high-risk EC. Methods: Fifty-two patients with intermediate- and high-risk EC underwent SLN biopsy after injection of a hybrid tracer using the TUMIR approach, followed by pelvic and paraaortic lymphadenectomy. SLNs were detected preoperatively by lymphoscintigraphic study and intraoperatively by gamma probe and near-infrared (NIR) optical laparoscopic camera. Results: Preoperative lymphatic drainage was obtained in 69% and intraoperative detection in 71.4% of patients. A total of 146 SLNs (4.17 SLNs/patient) were biopsied. Pelvic bilateral detection was observed in 57% of the women and paraaortic drainage in 34% of the patients. The radioactive component allowed the detection of SLN in 97.1% of the patients, while the fluorescent component detected 80%. In more than 17% of the patients with intraoperative detection, SLNs were detected only by the radioactive signal. Lymph node metastasis were identified in 14.3% of patients submitted to SLNB. The sensitivity and negative predictive value for metastatic involvement were 100%. Conclusion: TUMIR injection of a hybrid tracer in patients with intermediate- and high- risk EC combines the benefits of the radiotracer and the fluorescence methods with a single tracer. The method increases the paraaortic detection rate and allows a potential increase in SLN detection. Notwithstanding, based on our findings, the radioactive component of the hybrid tracer cannot be obviated.


Author(s):  
Anouk Overwater ◽  
Bas L. A. M. Weusten ◽  
Jelle P. Ruurda ◽  
Richard van Hillegersberg ◽  
Roel J. Bennink ◽  
...  

Abstract Background Minimally invasive esophagectomy with two-field lymphadenectomy is standard of care for T1b esophageal adenocarcinoma (EAC) with a high risk of lymph node metastasis. Sentinel node navigation surgery (SNNS) is a well-known concept to tailor the extent of lymphadenectomy. The aim of this study was to evaluate the feasibility and safety of SNNS with a hybrid tracer (technetium-99 m/indocyanine green/nanocolloid) for patients with high-risk T1b EAC. Methods In this prospective, multicenter pilot study, 5 patients with high-risk T1b EAC were included. The tracer was injected endoscopically around the endoscopic resection scar the day before surgery, followed by preoperative imaging (lymphoscintigraphy/SPECT-CT). During surgery, first the SNs were localized and resected based on preoperative imaging and intraoperative gammaprobe- and fluorescence-based detection, followed by esophagectomy. Primary endpoints were the percentage of patients with detectable SNs, concordance between preoperative and intraoperative SN detection, and the additive value of indocyanine green. Results SNs could be identified and resected in all patients (median 3 SNs per patient, range 2–7). There was a high concordance between preoperative and intraoperative SN detection. In 2 patients additional peritumoral SNs were identified with fluorescence-based detection. None of the resected lymph nodes showed signs of (micro)metastases and no nodal metastases were detected in the surgical resection specimen. Conclusions SNNS using technetium-99 m/indocyanine green/nanocolloid seems feasible and safe in patients with high-risk T1b EAC. Indocyanine green fluorescence seems to be of additive value for detection of peritumoral SNs. Whether this approach can optimize selection for esophagectomy needs to be studied in future research.


2018 ◽  
Vol 60 (1) ◽  
pp. 71-78 ◽  
Author(s):  
Margret Schottelius ◽  
Alexander Wurzer ◽  
Katharina Wissmiller ◽  
Roswitha Beck ◽  
Maximilian Koch ◽  
...  

2018 ◽  
Vol 24 (12) ◽  
pp. 1287-1303 ◽  
Author(s):  
Alfred O. Ankrah ◽  
Hans C. Klein ◽  
Philip H. Elsinga

Diabetic Foot Infections (DFIs) are associated with increased morbidity, an economic burden on patients, their families and healthcare systems and increased mortality. Early diagnosis with prompt, appropriate and adequate treatment of the infected diabetic foot is crucial. The determination of DFIs, however, may be quite perplexing and invasive. Imaging is useful in the evaluation of certain cases of DFIs, especially in suspected instances with no overt clinical features, or in the diagnosis of osteomyelitis. Nuclear medicine imaging is currently used in the evaluation of DFIs; however, like all the imaging techniques now available, it has its limitations. Several radiopharmaceuticals presently available play useful roles in the management of DFIs, while new ones are being evaluated. Optical imaging techniques have recently demonstrated promising results in the evaluation of many infections including DFIs. Using the same molecule, a tracer can be labeled with a radioisotope or an optical imaging dye. This enables infections to be evaluated both pre- and intra-operatively when surgery is required in their management. In some cases, tracers have been simultaneously labeled with both a radioisotope and an optical imaging dye to produce a hybrid tracer. These new tracers potentially provide powerful and new opportunities in the management of DFIs. In this review, we briefly examine tracers that have been used in the evaluation of the infected diabetic foot. We then explore the potential of new imaging tracers currently under development for infection that may be useful in the management of DFIs.


Sign in / Sign up

Export Citation Format

Share Document