mibi spect
Recently Published Documents


TOTAL DOCUMENTS

258
(FIVE YEARS 36)

H-INDEX

18
(FIVE YEARS 1)

Author(s):  
Berna Okudan ◽  
Bedri Seven ◽  
Nedim C.M. Gülaldı ◽  
Mustafa Çapraz ◽  
Yusuf Açıkgöz

Background: The therapeutic approaches of differentiated thyroid carcinoma (DTC) are surgery, ablation therapy with the postoperative use of radioiodine-131 (131I), and thyroid-stimulating hormone (TSH) suppression therapy. After the surgical therapy, the patient should be assessed for remnants/metastases. Objective: The purpose of this research was to investigate the role of technetium-99m-methoxyisobutylisonitrile (99mTc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) in the postoperative management of patients with DTC. Methods: The study comprised 22 DTC patients (13 women, 9 men; mean age 46.55 ± 13.27 y) who underwent a total thyroidectomy previously. All patients were investigated for thyroid remnants/metastases by 99mTc-MIBI SPECT/CT, posttherapy 131I whole-body scan (WBS) and ultrasound (US). Serum TSH, thyroglobulin and anti-Tg antibody levels were measured. Results of imaging modalities and laboratory measurements were compared with each other. Results: 99mTc-MIBI SPECT/CT, 131I WBS and US respectively demonstrated thyroid remnants in 15 (68.18%), 22 (100%) and 14 (63.63%) of the all patients and metastatic lymph nodes in 8 (100%), 6 (75%) and 6 (75%) of the 8 patients with lymph node metastases. 99mTc-MIBI SPECT/CT also demonstrated lung metastases in 2 patients (9.09% of all patients). The same result was obtained with 131I WBS. Conclusion : The findings of this study show that 99mTc-MIBI SPECT/CT can be effective for detecting metastases in patients with DTC who underwent surgery prior to 131I therapy.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ruigang Lu ◽  
Wei Zhao ◽  
Li Yin ◽  
Ruijun Guo ◽  
Bojun Wei ◽  
...  

Abstract Background Primary hyperparathyroidism (PHPT) results from an excess of parathyroid hormone (PTH) produced from an overactive parathyroid gland. The study aimed to explore the sonographic features of parathyroid adenomas and assess the diagnostic performance of ultrasonography (US) and Tc-99m MIBI SPECT/CT for preoperative localization of parathyroid adenomas. Methods A total of 107 patients were enrolled in this retrospective study who had PHPT and underwent parathyroidectomy. Of the 107 patients, 97 performed US and Tc-99m MIBI SPECT/CT examinations for preoperative localization of parathyroid nodules. The sensitivity and accuracy of each modality were calculated. Results In this study, residual parathyroid sign and polar vascular sign were identified as characteristic US features of parathyroid adenomas. These manifestations were closely related to the size of the abnormal parathyroid lesions. Among the 108 parathyroid nodules from 97 patients with PHPT, the sensitivity and accuracy of US for locating the parathyroid nodules were significantly higher than those of Tc-99m MIBI SPECT/CT (93.0% vs. 63.0% and 88.0% vs. 63.0% respectively; χ2 = 26.224, 18.227 respectively, P < 0.001). The differences between US + Tc-99m MIBI SPECT/CT and Tc-99m MIBI SPECT/CT-alone were statistically significant (χ2 = 33.410, 21.587 respectively, P < 0.001), yet there were no significant differences in the sensitivity or accuracy between US + Tc-99m MIBI SPECT/CT and US-alone (χ2 = 0.866, 0.187 respectively, P = 0.352 and 0.665). Conclusions US shows significantly better sensitivity and accuracy for localization of parathyroid adenomas than Tc-99m MIBI SPECT/CT. However, US combined with Tc-99m MIBI SPECT/CT is of great clinical value in the preoperative localization of parathyroid nodules in patients with PHPT.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Jing Gong ◽  
Aisheng Dong ◽  
Chengwei Shao

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Minting Zhu ◽  
Yang He ◽  
Tingting Liu ◽  
Bei Tao ◽  
Weiwei Zhan ◽  
...  

Background. Cervical ultrasound, 99mTc-sestamibi single-photon emission computed tomography/computed tomography (99mTc-MIBI SPECT/CT), and cervical CT are routinely used in preoperative localization of primary hyperparathyroidism (PHPT). However, false-negative imaging results are also frequently encountered in clinical practice. Exploring the factors that affect the sensitivity of these imaging modalities is important for the surgical management of PHPT patients. Methods. Clinical data of 352 PHPT patients hospitalized in our center from January 2011 to December 2015 were retrospectively collected to evaluate the sensitivity of 3 imaging modalities in the preoperative localization of parathyroid lesions. The ROC curve analysis was used to explore the clinical factors affecting the sensitivity of localization, and the cut-point(s) of related factors were determined. Results. 99mTc-MIBI SPECT/CT has the highest sensitivity among the localization modalities commonly used, reaching 91.1% (86.0%–94.8%). When the lengths of parathyroid lesions were ≤1.3 cm, the sensitivity of neck ultrasonography significantly decreased, while the sensitivity of 99mTc-MIBI SPECT/CT decreased with parathyroid lesions ≤1.3 cm or serum PTH≤252 pg/ml. 99mTc-MIBI SPECT/CT was less effective in localizing the hyperplasia lesions. Neck ultrasonography combined with 99mTc-MIBI SPECT/CT can effectively improve the accuracy of preoperative localization of parathyroid lesions to 96.2% (92.7%–98.1%). Conclusions. Small parathyroid lesion and mild elevation of serum PTH would reduce the accuracy of parathyroid localization in PHPT patients.


2021 ◽  
Author(s):  
Ruigang Lu ◽  
Wei Zhao ◽  
Li Yin ◽  
Ruijun Guo ◽  
Bojun Wei ◽  
...  

Abstract Background: Primary hyperparathyroidism (PHPT) results from an excess of parathyroid hormone (PTH) produced from an overactive parathyroid gland. The study aimed to explore the sonographic features of parathyroid adenomas and assess the diagnostic performance of ultrasonography (US) and Tc-99m MIBI SPECT/CT for preoperative localization of parathyroid adenomas. Methods: A total of 107 patients were enrolled in this retrospective study who had PHPT and underwent parathyroidectomy. Of the 107 patients, 97 performed US and Tc-99m MIBI SPECT/CT examinations for preoperative localization of parathyroid nodules. The sensitivity and accuracy of each modality were calculated. Results: In this study, residual parathyroid sign and polar vascular sign were identified as characteristic US features of parathyroid adenomas and these manifestations are closely related to the size of the abnormal parathyroid lesions. Using 108 parathyroid nodules from 97 patients with PHPT, the sensitivity and accuracy of US in locating parathyroid nodules were significantly higher than those of Tc-99m MIBI SPECT/CT (93.0% vs. 63.0% and 88.0% vs. 63.0%), and the difference was statistically significant (c²=26.224, 18.227, P<0.001). The difference between US combined with Tc-99m MIBI SPECT/CT and Tc-99m MIBI SPECT/CT-alone was statistically significant (c²=33.410, 21.587, P<0.001), yet there was no significant difference compared with US alone (c²=0.866, 0.187, P=0.352 and 0.665). Conclusions: US shows significantly better sensitivity and accuracy for localization of parathyroid adenomas than Tc-99m MIBI SPECT/CT. However, US combined with Tc-99m MIBI SPECT/CT is of great clinical value in the preoperative localization of parathyroid nodules in patients with PHPT.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Elske Quak ◽  
Audrey Lasne Cardon ◽  
Renaud Ciappuccini ◽  
Charline Lasnon ◽  
Vianney Bastit ◽  
...  

Abstract Background The common endocrine disorder primary hyperparathyroidism (PHPT) can be cured by surgery. Preoperative localization of parathyroid adenoma (PTA) by imaging is a prerequisite for outpatient minimally invasive parathyroidectomy (MIP). Compared to inpatient bilateral cervical exploration (BCE) which is performed if imaging is inconclusive, MIP is superior in terms of cure and complication rates and less costly. The imaging procedure F18-choline (FCH) PET/CT outperforms Tc99m-sestaMIBI (MIBI) SPECT/CT for PTA localization, but it is much costlier. The aim of this study is to identify the most efficient first-line imaging modality for optimal patient care in PHPT without added cost to society. Methods We will conduct a multicenter open diagnostic intervention randomized phase III trial comparing two diagnostic strategies in patients with PHPT: upfront FCH PET/CT versus MIBI SPECT/CT. The primary endpoint is the proportion of patients in whom the first-line imaging method results in successful MIP and cure. Follow-up including biological tests will be performed 1 and 6 months after surgery. The main secondary endpoint is the social cost of both strategies. Other secondary endpoints are as follows: FCH PET/CT and MIBI SPECT/CT diagnostic performance, performance of surgical procedure and complication rate, FCH PET/CT inter- and intra-observer variability and optimization of FCH PET/CT procedure. Fifty-eight patients will be enrolled and randomized 1:1. Discussion FCH PET/CT is a highly efficient but expensive imaging test for preoperative PTA localization and costs three to four times more than MIBI SPECT/CT. Whether FCH PET/CT improves patient outcomes compared to the reference standard MIBI SPECT/CT is unknown. To justify its added cost, FCH PET/CT-guided parathyroid surgery should lead to improved patient management, resulting in higher cure rates and fewer BCEs and surgical complications. In the previous phase II APACH1 study, we showed that second-line FCH PET/CT led to a cure in 88% of patients with negative or inconclusive MIBI SPECT/CT. BCE could be avoided in 75% of patients and surgical complication rates were low. We therefore hypothesize that upfront FCH PET/CT would improve patient care in PHPT and that the reduction in clinical costs would offset the increase in imaging costs. Trial registration NCT04040946, registered August 1, 2019.  Protocol version Version 2.1 dated from 2020/04/23.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Qi-chang Wan ◽  
Jian-fang Li ◽  
Lei-lei Tang ◽  
Jie Lv ◽  
liang-jun Xie ◽  
...  

2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Shu-Qin Jiang ◽  
Ting Yang ◽  
Qiong Zou ◽  
Lei Xu ◽  
Ting Ye ◽  
...  

Abstract Background This study aimed to compare the sensitivity of 99mTc-MIBI SPECT/CT, 99mTc-MIBI planar scintigraphy and ultrasonography (US) in patients with secondary hyperparathyroidism (SHPT), and to explore the factors that affect the sensitivity of 99mTc-MIBI SPECT/CT. Methods In this retrospective study, forty-six patients with SHPT who underwent 99mTc-MIBI planar scintigraphy, 99mTc-MIBI SPECT/CT and US were enrolled. They underwent surgery within 1 month. We compared the sensitivity of the different imaging methods based on the lesions according to the pathological results. The parathyroid lesions on 99mTc-MIBI SPECT/CT images were divided into missed diagnosis group (MDG) and non-missed diagnosis group (NMDG). We compared the lesion to background ratio (LBR), maximum diameter, volume, the mean CT Hounsfield unit values (CTmean) and location of lesions between MDG and NMDG. Results The sensitivity of 99mTc-MIBI SPECT/CT, 99mTc-MIBI planar scintigraphy and US were 70.30% versus 48.48% versus 61.82%, respectively. The sensitivity of 99mTc-MIBI SPECT/CT combined US was 79.39%, which was higher than 99mTc-MIBI SPECT/CT with significant difference (P = 0.000). On 99mTc-MIBI SPECT/CT images, the LBR, maximum diameter and volume of lesions in MDG was smaller than those in NMDG with significant difference (P < 0.001). The average LBR, maximum diameter and volume of lesions in MDG and NMDG were 3.42 ± 1.28, 9.32 ± 2.69 mm, 208.51 ± 163.22 mm3 versus 6.75 ± 5.08, 15.03 ± 4.94 mm and 863.85 ± 1216.0 mm3, respectively. Conclusions 99mTc-MIBI SPECT/CT exhibited the highest sensitivity among the three methods. When 99mTc-MIBI SPECT/CT combined with US, the sensitivity can be further improved. Lesions with lower MIBI uptake and smaller lesions on 99mTc-MIBI SPECT/CT images were easily missed.


Sign in / Sign up

Export Citation Format

Share Document