diffusion permeability
Recently Published Documents


TOTAL DOCUMENTS

57
(FIVE YEARS 11)

H-INDEX

15
(FIVE YEARS 1)

2021 ◽  
Vol 29 (4) ◽  
Author(s):  
Mohammed Qader Gubari ◽  
Haider Mohammed Zwain ◽  
Nadezda Vyacheslavovna Alekseeva

Cation exchange membrane (MK-40) is a commercial membrane with a fixed group that is an important part of the electrodialysis (ED) process. Sodium chloride (NaCl) diffusion and osmotic permeability for MK-40 was studied. A cell containing two compartments was used to analyse the properties of the MK-40 membrane fixed between them. Furthermore, the influence of temperature, NaCl concentration, and operating time on MK-40 properties was investigated. The results showed that the highest diffusion permeability coefficient of NaCl was 7.37×10-9 (m2/s), and the maximum osmotic permeability coefficient of distilled water was 43.8×10-9 (m2/s) at NaCl solution concentration of 0.1 M and 50oC. Generally, the permeability was constant beyond 60 min of operational time. Additionally, the minimum diffusion permeability coefficients of the MK-40 membrane fell by about 22% over time when the concentration of NaCl solution was 1 M at 25oC. To conclude, membrane properties in the ED process depend on the two electrodes (a cathode and an anode), without the diffusion of salts particles. Meanwhile, the most important properties of cation exchange membranes (CEMs) used in electrodialysis are increased membrane efficiency when water and salts transport decrease through CEMs, which leads to a decrease in energy consumption. Thus, the MK-40 membrane showed a good properties due to its low diffusion permeability for concentrated NaCl solution at elevated temperatures and minimum reduction in diffusion permeability of concentrated NaCl solution over time.


2021 ◽  
Vol 22 (8) ◽  
pp. 140-145
Author(s):  
Mohammed Gubari ◽  
Abdullah Abdulkarim ◽  
Nadezda Alekseeva

2021 ◽  
pp. 46-48
Author(s):  
D. V. Kolotilin ◽  
A. V. Dedov ◽  
R. I. Kunnap

The analysis of methods for assessing the diffusion permeability of polymer materials is carried out. The limitations of the methods for determining the tightness time and the rate of fuel bleeding from elastic tanks based on thermoplastic polyurethanes are shown. To solve the set tasks, an approach is proposed related to establishing dependencies of the kinetics of diesel fuel bleeding in the coordinate system of the conditional time, which was calculated as the square root of the process time. The tightness time and rate of fuel bleeding depends on the degree of filling of the tank during testing.


Author(s):  
Vasanthi Palanisamy ◽  
Palash Sanphui ◽  
Vaskuri G. S. Sainaga Jyothi ◽  
Nalini R Shastri ◽  
Geetha Bolla ◽  
...  

Author(s):  
D. A. Rodionov ◽  
S. I. Lazarev ◽  
K. K. Polyansky ◽  
E. V. Eckert ◽  
D. L. Polushkin

The paper presents the results of experimental data on the kinetic characteristics of ultrafiltration tubular elements, such as the output specific flow, retention coefficient, diffusion permeability coefficient, distribution coefficient. To study the purification of milk whey, we used tubular ultrafilters BTU 05/2 with membrane material fluoroplast (F), polyethersulfone (PESF), polysulfone (PS). For theoretical calculation of the retention coefficient, output specific flux, diffusion permeability coefficient, distribution coefficient, mathematical expressions were developed and empirical coefficients were obtained. The developed mathematical expression describes the experimental data with good reliability. The obtained experimental and calculated data can be used with high reliability in calculating mass-transfer fluxes of substances through a semi-permeable membrane, as well as in engineering methods for calculating and predicting efficiency, and using membrane processes for concentrating serum. The protein concentration in real milk whey was determined by formol titration. On the basis of the studies carried out, the dependence of the growth of the output specific flow on pressure was established, that the optimal pressure for concentrating milk whey on the ultrafiltration membranes we have chosen is 0.25 MPa. For three types of ultrafilters, the experimental value of the coefficient was within 99% for protein. For the theoretical calculation of the retention coefficient, a program in the MAXIMA language was developed and registered. Due to the method of applying the membrane to the reinforcing element, the membrane material polyethersulfone (PESF) and polysulfone (PS) have a substrate, due to which they sorb more substances on themselves, because of this, the diffusion permeability coefficient and the distribution coefficient are much higher than that of a filter element with membrane made of fluoroplastic (F), which does not have a substrate.


2020 ◽  
Vol 82 (2) ◽  
pp. 200-207
Author(s):  
I. V. Falina ◽  
O. A. Demina ◽  
N. A. Kononenko ◽  
I. A. Myakinchenko

Author(s):  
N. Ts. Gatapova ◽  
◽  
M. K. Dzhubari ◽  
N. V. Alekseeva ◽  
◽  
...  

The temperature modes of operation of ion-exchange membranes in an electrodialysis apparatus are described. The diffusion permeability of the MK-40 ion-exchange membrane has been experimentally investigated under the conditions of a temperature difference across the membrane at various concentrations of an aqueous solution of sodium chloride. The differences in the diffusion permeability of the membrane in thermostatic and thermodynamic modes are shown. The nature of the influence of the temperature drop across the membrane of aqueous sodium chloride solutions on changes in the value of the diffusion permeability coefficient of the MK-40 membrane was determined.


Sign in / Sign up

Export Citation Format

Share Document