transient study
Recently Published Documents


TOTAL DOCUMENTS

146
(FIVE YEARS 24)

H-INDEX

22
(FIVE YEARS 2)

Author(s):  
M. Ngom ◽  
A. Thiam ◽  
A. Balhamri ◽  
V. Sambou ◽  
Tarik Raffak ◽  
...  

2021 ◽  
Vol 245 ◽  
pp. 114586
Author(s):  
Margarida C. Pagaimo ◽  
João F.P. Fernandes ◽  
Modesto Pérez-Sánchez ◽  
P. Amparo López-Jiménez ◽  
Helena M. Ramos ◽  
...  
Keyword(s):  

Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 616
Author(s):  
Wenju Zhou ◽  
Zifeng Zhang ◽  
Qingwei Zhang ◽  
Dongfeng Qi ◽  
Tianxiang Xu ◽  
...  

Femtosecond laser-induced crystallization and ablation of Ge2Sb2Te5 (GST) phase change film is investigated by reflectivity pump-probing technology. Below the ablation threshold, the face-centered cubic structure (FCC) state in the central area can be formed, and cylindrical rims are formed in the peripheral dewetting zone due to the solidification of transported matter. The time of surface temperature dropping to the crystallization point needs about 30 ps for 5.86 mJ/cm2 and 82 ps for 7.04 mJ/cm2, respectively. At higher laser fluence, crystallization GST island structures appear in the central ablation region due to the extremely short heating time (100 ps). Furthermore, crystallization rate is faster than the ablation rate of the GST film, which is caused by different reflectivity.


Processes ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 438
Author(s):  
Sherif Salama Mohamed Ghoneim ◽  
Mahrous Ahmed ◽  
Nehmdoh Abdelmotaleb Sabiha

This paper presents the computation of the cable ampacity and the temperature distribution through long duration based on the equivalent thermal circuit based on IEC 60287 standard and the Finite element method using COMSOL (Multiphysics environment, version 5.5). This study investigated the cable ampacity and the temperature rise of the cable core and sheath at steady state and emergency conditions. The cable ampacity was investigated at different conditions such as the variation of cable depth, soil properties, and soil temperature. The results confirmed the adaptation between the thermal circuit results and the COMSOL results as well as the effectiveness of using the numerical method to compute the cable ampacity. Using the COMSOL-based thermal properties evaluations, the transient performance of the cable is ascertained. The transient study is performed for different cable loading currents and dry zone sizes.


2021 ◽  
Vol 81 ◽  
pp. 811-822
Author(s):  
Mohammadreza DaqiqShirazi ◽  
Azeez A. Barzinjy ◽  
Samir M. Hamad ◽  
Rezvan Alamian ◽  
Mostafa Safdari Shadloo

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Lili Wu ◽  
Fayu Wan ◽  
Rym Assila Belhadj Mefteh ◽  
Remy Vauche ◽  
George Chan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document