energy of transfer
Recently Published Documents


TOTAL DOCUMENTS

109
(FIVE YEARS 3)

H-INDEX

21
(FIVE YEARS 0)

Author(s):  
Simon Gourdin-Bertin ◽  
Jean-François Dufrêche ◽  
Magali Duvail ◽  
Thomas Zemb


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Md Ackas Ali ◽  
Md. Ruhul Amin ◽  
Shamim Mahbub ◽  
Md. Delwar Hossen ◽  
Md. Anamul Hoque ◽  
...  

Abstract Mixed surfactant systems are used in different applied fields like pharmaceutical formulation rather than single surfactant. Therefore, the determination of the clouding nature of the triton X-100 (TX-100) + Tween 80 (TW-80) mixture was carried out in H2O and polyvinyl alcohol (PVA). In the occurrence of PVA, the cloud point (CP) values of TX-100 initially enhance with enhancing the concentration of PVA and tend to decrease after a certain concentration. For different ratios of TX-100 and TW-80 mixture having the same concentration of both solutions, CP values increase through the decreasing ratios of TX-100 with/without PVA. In the presence of polymer, at higher ratios of TX-100 than TW-80, the CP values are higher in magnitudes in comparison to the aqueous medium but at lower ratios of TX-100, the value of CP are lower in magnitudes in comparison to the aqueous system. The CP values of the TX-100 + TW-80 mixture in the salt system are lower in magnitudes than the aqueous medium in both the absence/presence of PVA. However, a reduction of CP values was obtained to a large extent for Na2SO4 over NaCl in the case of lower volume ratios of TX-100. Various thermodynamic variables (standard free energy ( Δ G c o ${\Delta}{G}_{c}^{o}$ ), standard enthalpy ( Δ H c o ${\Delta}{H}_{c}^{o}$ ), standard entropy ( Δ S c o ${\Delta}{S}_{c}^{o}$ ) change, thermodynamic parameters of transfer (free energy of transfer ( Δ G c , t o ${\Delta}{G}_{c,t}^{o}$ ), and transfer of enthalpies ( Δ H c , t o ${\Delta}{H}_{c,t}^{o}$ )) of phase transition) were also determined.



Chemosensors ◽  
2021 ◽  
Vol 9 (1) ◽  
pp. 15
Author(s):  
Eissa Mohamed Almbrok ◽  
Nor Azah Yusof ◽  
Jaafar Abdullah ◽  
Ruzniza Mohd Zawawi

Electrochemical characterization and detection of protonated dibucaine (DIC+) at microinterface array across water|1,6-dichlorohexane were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Some thermodynamic parameters of dibucaine, such as the standard transfer potential, the Gibbs energy of transfer and the partition coefficient, were estimated by CV. In addition to the analytical parameters, the impact of bovine serum albumin (BSA) on dibucaine detection (in artificial serum matrices) was also investigated. DPV was applied to detect a lower concentration of DIC+, resulting in a detection limit of 0.9 ± 0.06 µM. While the presence of BSA affected CV, demonstrated as reduced current responses, DPV was confirmed to be an efficient method for lowering concentrations of the dibucaine detection in the artificial serum matrix in the presence of BSA, with a limit of detection (LOD) of 1.9 ± 0.12 µM.



Chemosensors ◽  
2020 ◽  
Vol 8 (1) ◽  
pp. 11
Author(s):  
Eissa Mohamed Almbrok ◽  
Nor Azah Yusof ◽  
Jaafar Abdullah ◽  
Ruzniza Mohd Zawawi

The electrochemical behavior when the liquid–liquid interface was modified by commercially available, microporous silicon nitride membrane, was achieved using cyclic voltammetry with tetramethyl ammonium. The transfer characteristics of the ionizable drug diclofenac ( DCF − ), as an anti-inflammatory, anti-rheumatic, antipyretic, and analgesic treatment in common use in biomedical applications, were also investigated across microporous silicon nitride-modified liquid interface. Thus, some thermodynamic variables for DCF − , such as the standard Gibbs energy of transfer, the standard transfer potential and lipophilicity were estimated. Furthermore, the influence of possible interfering substances (ascorbic acid, sugar, amino acid, urea, and metal ions) on the detection of DCF − was investigated. An electrochemical DCF sensor is investigated using differential pulse voltammetry (DPV) as the quantification technique, a linear range of 8–56 µM and a limit of detection of 1.5 µM was possible due to the miniaturized interfaces formed within silicon nitride.



2017 ◽  
Vol 468 ◽  
pp. 283-289 ◽  
Author(s):  
Yoko Sugawara ◽  
Yuji Hirano ◽  
Shigefumi Yamamura ◽  
Shigeru Endo ◽  
Masanori Ootaki ◽  
...  


2016 ◽  
Author(s):  
Heinz Gamsjäger ◽  
John W. Lorimer ◽  
Pirketta Scharlin ◽  
David G. Shaw


2015 ◽  
Vol 143 (14) ◽  
pp. 144108 ◽  
Author(s):  
Davide Bochicchio ◽  
Emanuele Panizon ◽  
Riccardo Ferrando ◽  
Luca Monticelli ◽  
Giulia Rossi


2015 ◽  
Vol 119 (41) ◽  
pp. 13167-13176 ◽  
Author(s):  
Toshiyuki Osakai ◽  
Yasuhiro Naito ◽  
Kazuo Eda ◽  
Masahiro Yamamoto


2013 ◽  
Vol 26 (2) ◽  
pp. 351-358 ◽  
Author(s):  
Patrick Gan ◽  
Denise Lowinsohn ◽  
John S Foord ◽  
Richard G Compton


Sign in / Sign up

Export Citation Format

Share Document