International Journal of Neural Systems
Latest Publications


TOTAL DOCUMENTS

1550
(FIVE YEARS 248)

H-INDEX

62
(FIVE YEARS 11)

Published By World Scientific

1793-6462, 0129-0657

Author(s):  
Ziliang Cai ◽  
Lingyue Wang ◽  
Miaomiao Guo ◽  
Guizhi Xu ◽  
Lei Guo ◽  
...  

Emotion plays a significant role in human daily activities, and it can be effectively recognized from EEG signals. However, individual variability limits the generalization of emotion classifiers across subjects. Domain adaptation (DA) is a reliable method to solve the issue. Due to the nonstationarity of EEG, the inferior-quality source domain data bring negative transfer in DA procedures. To solve this problem, an auto-augmentation joint distribution adaptation (AA-JDA) method and a burden-lightened and source-preferred JDA (BLSP-JDA) approach are proposed in this paper. The methods are based on a novel transfer idea, learning the specific knowledge of the target domain from the samples that are appropriate for transfer, which reduces the difficulty of transfer between two domains. On multiple emotion databases, our model shows state-of-the-art performance.


Author(s):  
M. C. Maya-Piedrahita ◽  
P. M. Herrera-Gomez ◽  
L. Berrío-Mesa ◽  
D. A. Cárdenas-Peña ◽  
A. A. Orozco-Gutierrez

As a neurodevelopmental pathology, Attention Deficit Hyperactivity Disorder (ADHD) mainly arises during childhood. Persistent patterns of generalized inattention, impulsivity, or hyperactivity characterize ADHD that may persist into adulthood. The conventional diagnosis relies on clinical observational processes yielding high rates of overdiagnosis due to varying interpretations among specialists or missing information. Although several studies have designed objective behavioral features to overcome such an issue, they lack significance. Despite electroencephalography (EEG) analyses extracting alternative biomarkers using signal processing techniques, the nonlinearity and nonstationarity of EEG signals restrain performance and generalization of hand-crafted features. This work proposes a methodology to support ADHD diagnosis by characterizing EEG signals from hidden Markov models (HMM), classifying subjects based on similarity measures for probability functions, and spatially interpreting the results using graphic embeddings of stochastic dynamic models. The methodology learns a single HMM for EEG signal from each patient, so favoring the inter-subject variability. Then, the Probability Product Kernel, specifically developed for assessing the similarity between HMMs, fed a support vector machine that classifies subjects according to their stochastic dynamics. Lastly, the kernel variant of Principal Component Analysis provided a means to visualize the EEG transitions in a two-dimensional space, evidencing dynamic differences between ADHD and Healthy Control children. From the electrophysiological perspective, we recorded EEG under the Stop Signal Task modified with reward levels, which considers cognitive features of interest as insufficient motivational circuits recruitment. The methodology compares the supported diagnosis in two EEG channel setups (whole channel set and channels of interest in frontocentral area) and four frequency bands (Theta, Alpha, Beta rhythms, and a wideband). Results evidence an accuracy rate of 97.0% in the Beta band and in the channels where previous works found error-related negativity events. Such accuracy rate strongly supports the dual pathway hypothesis and motivational deficit concerning the pathophysiology of ADHD. It also demonstrates the utility of joining inhibitory and motivational paradigms with dynamic EEG analysis into a noninvasive and affordable diagnostic tool for ADHD patients.


Author(s):  
Juan E Arco ◽  
Andrés Ortiz ◽  
Javier Ramírez ◽  
Yu-Dong Zhang ◽  
Juan M Górriz

The automation in the diagnosis of medical images is currently a challenging task. The use of Computer Aided Diagnosis (CAD) systems can be a powerful tool for clinicians, especially in situations when hospitals are overflowed. These tools are usually based on artificial intelligence (AI), a field that has been recently revolutionized by deep learning approaches. blackThese alternatives usually obtain a large performance based on complex solutions, leading to a high computational cost and the need of having large databases. In this work, we propose a classification framework based on sparse coding. Images are blackfirst partitioned into different tiles, and a dictionary is built after applying PCA to these tiles. The original signals are then transformed as a linear combination of the elements of the dictionary. blackThen, they are reconstructed by iteratively deactivating the elements associated with each component. Classification is finally performed employing as features the subsequent reconstruction errors. Performance is evaluated in a real context where distinguishing between four different pathologies: control versus bacterial pneumonia versus viral pneumonia versus COVID-19. blackOur system differentiates between pneumonia patients and controls with an accuracy of 97.74%, whereas in the 4-class context the accuracy is 86.73%. The excellent results and the pioneering use of sparse coding in this scenario evidence that our proposal can assist clinicians when their workload is high.


Author(s):  
Ehsan Mohammadi ◽  
Bahador Makkiabadi ◽  
Mohammad Bagher Shamsollahi ◽  
Parham Reisi ◽  
Saeed Kermani

Many studies in the field of sleep have focused on connectivity and coherence. Still, the nonstationary nature of electroencephalography (EEG) makes many of the previous methods unsuitable for automatic sleep detection. Time-frequency representations and high-order spectra are applied to nonstationary signal analysis and nonlinearity investigation, respectively. Therefore, combining wavelet and bispectrum, wavelet-based bi-phase (Wbiph) was proposed and used as a novel feature for sleep–wake classification. The results of the statistical analysis with emphasis on the importance of the gamma rhythm in sleep detection show that the Wbiph is more potent than coherence in the wake–sleep classification. The Wbiph has not been used in sleep studies before. However, the results and inherent advantages, such as the use of wavelet and bispectrum in its definition, suggest it as an excellent alternative to coherence. In the next part of this paper, a convolutional neural network (CNN) classifier was applied for the sleep–wake classification by Wbiph. The classification accuracy was 97.17% in nonLOSO and 95.48% in LOSO cross-validation, which is the best among previous studies on sleep–wake classification.


Author(s):  
Xiaowei Che ◽  
Yuanjie Zheng ◽  
Xin Chen ◽  
Sutao Song ◽  
Shouxin Li

Color has an important role in object recognition and visual working memory (VWM). Decoding color VWM in the human brain is helpful to understand the mechanism of visual cognitive process and evaluate memory ability. Recently, several studies showed that color could be decoded from scalp electroencephalogram (EEG) signals during the encoding stage of VWM, which process visible information with strong neural coding. Whether color could be decoded from other VWM processing stages, especially the maintaining stage which processes invisible information, is still unknown. Here, we constructed an EEG color graph convolutional network model (ECo-GCN) to decode colors during different VWM stages. Based on graph convolutional networks, ECo-GCN considers the graph structure of EEG signals and may be more efficient in color decoding. We found that (1) decoding accuracies for colors during the encoding, early, and late maintaining stages were 81.58%, 79.36%, and 77.06%, respectively, exceeding those during the pre-stimuli stage (67.34%), and (2) the decoding accuracy during maintaining stage could predict participants’ memory performance. The results suggest that EEG signals during the maintaining stage may be more sensitive than behavioral measurement to predict the VWM performance of human, and ECo-GCN provides an effective approach to explore human cognitive function.


2021 ◽  
Vol 32 (01) ◽  
Author(s):  
Ting Hu ◽  
Lizhang Xie ◽  
Lei Zhang ◽  
Guangjun Li ◽  
Zhang Yi

Patient-specific quality assurance (QA) for Volumetric Modulated Arc Therapy (VMAT) plans is routinely performed in the clinical. However, it is labor-intensive and time-consuming for medical physicists. QA prediction models can address these shortcomings and improve efficiency. Current approaches mainly focus on single cancer and single modality data. They are not applicable to clinical practice. To assess the accuracy of QA results for VMAT plans, this paper presents a new model that learns complementary features from the multi-modal data to predict the gamma passing rate (GPR). According to the characteristics of VMAT plans, a feature-data fusion approach is designed to fuse the features of imaging and non-imaging information in the model. In this study, 690 VMAT plans are collected encompassing more than ten diseases. The model can accurately predict the most VMAT plans at all three gamma criteria: 2%/2 mm, 3%/2 mm and 3%/3 mm. The mean absolute error between the predicted and measured GPR is 2.17%, 1.16% and 0.71%, respectively. The maximum deviation between the predicted and measured GPR is 3.46%, 4.6%, 8.56%, respectively. The proposed model is effective, and the features of the two modalities significantly influence QA results.


Author(s):  
Nedime Karakullukcu ◽  
Bülent Yilmaz

Patients with motor impairments need caregivers’ help to initiate the operation of brain-computer interfaces (BCI). This study aims to identify and characterize movement intention using multichannel electroencephalography (EEG) signals as a means to initiate BCI systems without extra accessories/methodologies. We propose to discriminate the resting and motor imagery (MI) states with high accuracy using Fourier-based synchrosqueezing transform (FSST) as a feature extractor. FSST has been investigated and compared with other popular approaches in 28 healthy subjects for a total of 6657 trials. The accuracy and f-measure values were obtained as 99.8% and 0.99, respectively, when FSST was used as the feature extractor and singular value decomposition (SVD) as the feature selection method and support vector machines as the classifier. Moreover, this study investigated the use of data that contain certain amount of noise without any preprocessing in addition to the clean counterparts. Furthermore, the statistical analysis of EEG channels with the best discrimination (of resting and MI states) characteristics demonstrated that F4-Fz-C3-Cz-C4-Pz channels and several statistical features had statistical significance levels, [Formula: see text], less than 0.05. This study showed that the preparation of the movement can be detected in real-time employing FSST-SVD combination and several channels with minimal pre-processing effort.


Author(s):  
Guoyang Liu ◽  
Lan Tian ◽  
Weidong Zhou

Automatic seizure detection is of great significance for epilepsy diagnosis and alleviating the massive burden caused by manual inspection of long-term EEG. At present, most seizure detection methods are highly patient-dependent and have poor generalization performance. In this study, a novel patient-independent approach is proposed to effectively detect seizure onsets. First, the multi-channel EEG recordings are preprocessed by wavelet decomposition. Then, the Convolutional Neural Network (CNN) with proper depth works as an EEG feature extractor. Next, the obtained features are fed into a Bidirectional Long Short-Term Memory (BiLSTM) network to further capture the temporal variation characteristics. Finally, aiming to reduce the false detection rate (FDR) and improve the sensitivity, the postprocessing, including smoothing and collar, is performed on the outputs of the model. During the training stage, a novel channel perturbation technique is introduced to enhance the model generalization ability. The proposed approach is comprehensively evaluated on the CHB-MIT public scalp EEG database as well as a more challenging SH-SDU scalp EEG database we collected. Segment-based average accuracies of 97.51% and 93.70%, event-based average sensitivities of 86.51% and 89.89%, and average AUC-ROC of 90.82% and 90.75% are yielded on the CHB-MIT database and SH-SDU database, respectively.


Sign in / Sign up

Export Citation Format

Share Document