EFFECT OF RETROCHIASMAL LESION UPON VARIABILITY OF THE ABSOLUTE VISUAL THRESHOLD

1953 ◽  
Vol 70 (1) ◽  
pp. 70
Author(s):  
HOWARD P. KRIEGER
1959 ◽  
Vol 146 (1) ◽  
pp. 179-184 ◽  
Author(s):  
F. H. C. Marriott ◽  
Valerie B. Morris ◽  
M. H. Pirenne

2017 ◽  
Vol 372 (1717) ◽  
pp. 20160066 ◽  
Author(s):  
Carola A. M. Yovanovich ◽  
Sanna M. Koskela ◽  
Noora Nevala ◽  
Sergei L. Kondrashev ◽  
Almut Kelber ◽  
...  

The presence of two spectrally different kinds of rod photoreceptors in amphibians has been hypothesized to enable purely rod-based colour vision at very low light levels. The hypothesis has never been properly tested, so we performed three behavioural experiments at different light intensities with toads ( Bufo ) and frogs ( Rana ) to determine the thresholds for colour discrimination. The thresholds of toads were different in mate choice and prey-catching tasks, suggesting that the differential sensitivities of different spectral cone types as well as task-specific factors set limits for the use of colour in these behavioural contexts. In neither task was there any indication of rod-based colour discrimination. By contrast, frogs performing phototactic jumping were able to distinguish blue from green light down to the absolute visual threshold, where vision relies only on rod signals. The remarkable sensitivity of this mechanism comparing signals from the two spectrally different rod types approaches theoretical limits set by photon fluctuations and intrinsic noise. Together, the results indicate that different pathways are involved in processing colour cues depending on the ecological relevance of this information for each task. This article is part of the themed issue ‘Vision in dim light’.


1947 ◽  
Vol 30 (10) ◽  
pp. 439-447
Author(s):  
G. WESTHEIMER

Author(s):  
P. Echlin ◽  
M. McKoon ◽  
E.S. Taylor ◽  
C.E. Thomas ◽  
K.L. Maloney ◽  
...  

Although sections of frozen salt solutions have been used as standards for x-ray microanalysis, such solutions are less useful when analysed in the bulk form. They are poor thermal and electrical conductors and severe phase separation occurs during the cooling process. Following a suggestion by Whitecross et al we have made up a series of salt solutions containing a small amount of graphite to improve the sample conductivity. In addition, we have incorporated a polymer to ensure the formation of microcrystalline ice and a consequent homogenity of salt dispersion within the frozen matrix. The mixtures have been used to standardize the analytical procedures applied to frozen hydrated bulk specimens based on the peak/background analytical method and to measure the absolute concentration of elements in developing roots.


Author(s):  
C. M. Payne ◽  
P. M. Tennican

In the normal peripheral circulation there exists a sub-population of lymphocytes which is ultrastructurally distinct. This lymphocyte is identified under the electron microscope by the presence of cytoplasmic microtubular-like inclusions called parallel tubular arrays (PTA) (Figure 1), and contains Fc-receptors for cytophilic antibody. In this study, lymphocytes containing PTA (PTA-lymphocytes) were quantitated from serial peripheral blood specimens obtained from two patients with Epstein -Barr Virus mononucleosis and two patients with cytomegalovirus mononucleosis. This data was then correlated with the clinical state of the patient.It was determined that both the percentage and absolute number of PTA- lymphocytes was highest during the acute phase of the illness. In follow-up specimens, three of the four patients' absolute lymphocyte count fell to within normal limits before the absolute PTA-lymphocyte count.In one patient who was followed for almost a year, the absolute PTA- lymphocyte count was consistently elevated (Figure 2). The estimation of absolute PTA-lymphocyte counts was determined to be valid after a morphometric analysis of the cellular areas occupied by PTA during the acute and convalescent phases of the disease revealed no statistical differences.


Author(s):  
Stuart McKernan ◽  
C. Barry Carter

The determination of the absolute polarity of a polar material is often crucial to the understanding of the defects which occur in such materials. Several methods exist by which this determination may be performed. In bulk, single-domain specimens, macroscopic techniques may be used, such as the different etching behavior, using the appropriate etchant, of surfaces with opposite polarity. X-ray measurements under conditions where Friedel’s law (which means that the intensity of reflections from planes of opposite polarity are indistinguishable) breaks down can also be used to determine the absolute polarity of bulk, single-domain specimens. On the microscopic scale, and particularly where antiphase boundaries (APBs), which separate regions of opposite polarity exist, electron microscopic techniques must be employed. Two techniques are commonly practised; the first [1], involves the dynamical interaction of hoLz lines which interfere constructively or destructively with the zero order reflection, depending on the crystal polarity. The crystal polarity can therefore be directly deduced from the relative intensity of these interactions.


Sign in / Sign up

Export Citation Format

Share Document