scholarly journals Intra‐fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases

2021 ◽  
Vol 22 (3) ◽  
pp. 254-260
Author(s):  
Riho Komiyama ◽  
Shingo Ohira ◽  
Hikari Ueda ◽  
Naoyuki Kanayama ◽  
Akira Masaoka ◽  
...  
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Nzhde Agazaryan ◽  
Steve Tenn ◽  
Chul Lee ◽  
Michael Steinberg ◽  
John Hegde ◽  
...  

Abstract Purpose/objective(s) To communicate our institutional experience with single isocenter radiosurgery treatments for multiple brain metastases, including challenges with determining planning target volume (PTV) margins and resulting consequences, image-guidance translational and rotational tolerances, intra-fraction patient motion, and prescription considerations with larger PTV margins. Materials/methods Eight patient treatments with 51 targets were planned with various margins using Elements Multiple Brain Mets SRS treatment planning software (Brainlab, Munich, Germany). Forty-eight plans with 0 mm, 1 mm and 2 mm margins were created, including plans with variable margins, where targets more than 6 cm away from the isocenter were planned with larger margins. The dosimetric impact of the margins were analyzed with V5Gy, V8Gy, V10Gy, V12Gy values. Additionally, 12 patient motion data were analyzed to determine both the impact of the repositioning threshold and the distributions of the patient translational and rotational movements. Results The V5Gy, V8Gy, V10Gy, V12Gy volumes approximately doubled when margins change from 0 to 1 mm and tripled when change from 0 to 2 mm. With variable margins, the aggregated results are similar to results from plans using the lower of two margins, since only 12.2% of the targets were more than 6 cm away from the isocenter. With 0.5 mm re-positioning threshold, 57.4% of the time the patients are repositioned. Reducing the threshold to 0.25 mm results in 91.7% repositioning rate, due to limitations of the fusion algorithm and actual patient motion. The 90th percentile of translational movements in all directions is 0.7 mm, while the 90th percentile of rotational movements in all directions is 0.6 degrees. Median translations and rotations are 0.2 mm and 0.2 degrees, respectively. Conclusions Based on the data presented, we have switched our modus operandi from 2 to 1 mm PTV margins, with an eventual goal of using 0.5 and 1.0 mm variable margins when an automated margin assignment method becomes available. The 0.5 mm and 0.5 degrees repositioning thresholds are clinically appropriate with small residual patient movements.


2001 ◽  
Vol 58 (7) ◽  
pp. 413-418 ◽  
Author(s):  
Jean Siegfried ◽  
G. Wellis ◽  
S. Scheib ◽  
D. Haller ◽  
A. M. Landolt ◽  
...  

Das Gamma Knife ist ein stereotaktisch-radiochirurgisches Gerät, das erlaubt, radiologisch scharf begrenzte Hirntumore (oder arteriovenöse Missbildungen) mit einem Durchmesser von maximal 3,5 cm und einem Volumen von höchstens 25 cm3 zu behandeln. Diese Methode ist eine echte Alternative zur klassischen Behandlung von Hirnmetastasen mit operativer Entfernung und/oder Ganzhirnbestrahlung. Die Vorteile dieser Technik sind klar: die Methode ist nicht invasiv, die Behandlung benötigt nur eine Sitzung mit einer kurzen Hospitalisation von höchstens zwei bis drei Tagen, die physische und psychische Belastung ist gering, der Kopf wird weder rasiert noch verliert der Patient durch die Behandlung seine Haare; für eine befriedigende Überlebenszeit wird eine gute Lebensqualität erreicht und im Kostenvergleich mit alternativen Methoden (Operation und/oder anschließender Ganzhirnbestrahlung) wirtschaftlich günstiger. Von September 1994 bis Dezember 2000 wurden am Gamma Knife Zentrum in Zürich 140 an Hirnmetastasen leidende Patienten mit dieser Methode behandelt. Mit einer Überlebenszeit von durchschnittlich 263 Tagen und einem Maximum von drei Jahren entsprechen unsere Resultate denjenigen der Literatur mit weltweit über 30000 behandelten Patienten. Günstige Prognosen sind ein Karnofsky Performance Rating Scale Score zwischen 70 und 100, kleine Volumina der Metastasen, kontrollierter Primärtumor und fehlende oder stabile extrakranielle Metastasen.


2012 ◽  
Vol 73 (S 02) ◽  
Author(s):  
M. Amit ◽  
L. Laider-Trejo ◽  
A. Shabtay ◽  
Z. Gil

Author(s):  
S. Marbacher ◽  
E. Klinger ◽  
L. Schwzer ◽  
I. Fischer ◽  
E. Nevzati ◽  
...  

2016 ◽  
Vol 76 (10) ◽  
Author(s):  
E Laakmann ◽  
I Witzel ◽  
A Thiesen ◽  
T Fehm ◽  
G von Minckwitz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document