Radiographic estimation of long bone cross-sectional geometric properties

1993 ◽  
Vol 90 (2) ◽  
pp. 207-213 ◽  
Author(s):  
Jacqueline A. Runestad ◽  
Christopher B. Ruff ◽  
James C. Nieh ◽  
Richard W. Thorington ◽  
Mark F. Teaford
1998 ◽  
Vol 1 (4) ◽  
pp. 303-319 ◽  
Author(s):  
MARC E. LEVENSTON ◽  
GARY S. BEAUPRÉ ◽  
DENNIS R. CARTER

Author(s):  
Wenhuan Sun ◽  
Jason Paulovich ◽  
Victoria Webster-Wood

Abstract Electrochemically Aligned Collagen (ELAC) threads fabricated by the isoelectric focusing (IF) of collagen have previously shown potential in tissue engineering and more recently in the fabrication of biohybrid robot structures. For applications in biohybrid robotics, ELAC structures are needed that are both robust and compliant enough to facilitate muscle actuation. However, studies on the effects of IF parameters, and the interactions of such fabrication parameters, on the mechanical and geometric properties of resulting ELAC threads have not been previously found in literature. Understanding the impact of these manufacturing parameters on the material properties is critical to facilitate biohybrid robot design. In this study, the effects of IF duration, IF voltage, and collagen solution concentration were investigated and showed statistically significant effects on adjusting ELAC properties via single-factor experiments. The interactions between parameters exhibited significant joint effects on ELAC property tuning through two-factor experiments. Scanning electron microscopy and 2,4,6-trinitrobenzenesulfonic assays revealed the correlation between high mechanical properties and a combination of low porosity and high degree of crosslinking. By simply tuning IF parameters without changing other fabrication steps, such as crosslinker concentration, ELAC threads with a wide range of mechanical and geometric properties were fabricated. The average tensile modulus of the resulting ELAC threads ranged from 198±90 to 758±138 MPa. The average cross-sectional area ranged from 7756±1000 to 1775±457 µm2. The resultant mapping between IF parameters and ELAC thread properties enabled the production of strong and flexible threads with customizable properties.


Author(s):  
Christopher B. Ruff ◽  
Ryan W. Higgins ◽  
Kristian J. Carlson

Long bone diaphyseal cross-sectional geometries reflect the mechanical properties of the bones, and can be used to aid in inferences of locomotor behavior in extinct hominins. This chapter considers all available long bone diaphyseal and femoral neck cross-sections of specimens from Sterkfontein Member 4, and presents comparisons of these section properties and other cross-sectional dimensions with those of other early hominins as well as modern samples. The cross-sectional geometry of the Sterkfontein Member 4 long bone specimens suggests some similarities to, but also interesting differences in, mechanical loading of these elements relative to modern humans. The less asymmetric cortical bone distribution in the Sterkfontein femoral necks is consistent with other evidence above indicating an altered gait pattern involving lateral displacement of the body center of mass over the stance limb. The relatively very strong upper limb of StW 431 implies that arboreal behavior formed a significant component of its locomotor repertoire. Bipedal gait may have been less efficient and arboreal climbing more prevalent in the Sterkfontein hominins.


2018 ◽  
Vol 3 (4) ◽  
pp. 101 ◽  
Author(s):  
Joel Galindo-Avalos ◽  
Avelino Colín-Vázquez ◽  
LuisDario Bernal-Fortich ◽  
Juan López-Valencia ◽  
Rafael Grajales-Ruiz ◽  
...  

2011 ◽  
Vol 279 (1728) ◽  
pp. 451-456 ◽  
Author(s):  
Roger S. Seymour ◽  
Sarah L. Smith ◽  
Craig R. White ◽  
Donald M. Henderson ◽  
Daniela Schwarz-Wings

The cross-sectional area of a nutrient foramen of a long bone is related to blood flow requirements of the internal bone cells that are essential for dynamic bone remodelling. Foramen area increases with body size in parallel among living mammals and non-varanid reptiles, but is significantly larger in mammals. An index of blood flow rate through the foramina is about 10 times higher in mammals than in reptiles, and even higher if differences in blood pressure are considered. The scaling of foramen size correlates well with maximum whole-body metabolic rate during exercise in mammals and reptiles, but less well with resting metabolic rate. This relates to the role of blood flow associated with bone remodelling during and following activity. Mammals and varanid lizards have much higher aerobic metabolic rates and exercise-induced bone remodelling than non-varanid reptiles. Foramen areas of 10 species of dinosaur from five taxonomic groups are generally larger than from mammals, indicating a routinely highly active and aerobic lifestyle. The simple measurement holds possibilities offers the possibility of assessing other groups of extinct and living vertebrates in relation to body size, behaviour and habitat.


Sign in / Sign up

Export Citation Format

Share Document