Study on the process of fermentation coupling with foam fractionation and membrane module for nisin production

2014 ◽  
pp. n/a-n/a
Author(s):  
Xiaoying Cui ◽  
Da Zhang ◽  
Huijie Zheng ◽  
Zhaoliang Wu ◽  
Shaofei Cui ◽  
...  
LWT ◽  
2021 ◽  
Vol 142 ◽  
pp. 111093
Author(s):  
Wei Liu ◽  
Jingping Zhou ◽  
Fangdai Tan ◽  
Hao Yin ◽  
Chunyan Yang ◽  
...  

Foods ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 898
Author(s):  
Hebatoallah Hassan ◽  
Daniel St-Gelais ◽  
Ahmed Gomaa ◽  
Ismail Fliss

Clostridium tyrobutyricum spores survive milk pasteurization and cause late blowing of cheeses and significant economic loss. The effectiveness of nisin-producing Lactococcus lactis ssp. lactis 32 as a protective strain for control the C. tyrobutyricum growth in Cheddar cheese slurry was compared to that of encapsulated nisin-A. The encapsulated nisin was more effective, with 1.0 log10 reductions of viable spores after one week at 30 °C and 4 °C. Spores were not detected for three weeks at 4 °C in cheese slurry made with 1.3% salt, or during week 2 with 2% salt. Gas production was observed after one week at 30 °C only in the control slurry made with 1.3% salt. In slurry made with the protective strain, the reduction in C. tyrobutyricum count was 0.6 log10 in the second week at 4 °C with both salt concentration. At 4 °C, nisin production started in week 2 and reached 97 µg/g after four weeks. Metabarcoding analysis targeting the sequencing of 16S rRNA revealed that the genus Lactococcus dominated for four weeks at 4 °C. In cheese slurry made with 2% salt, the relative abundance of the genus Clostridium decreased significantly in the presence of nisin or the protective strain. The results indicated that both strategies are able to control the growth of Clostridium development in Cheddar cheese slurries.


Author(s):  
Qianfeng Gu ◽  
Xiaochen Xue ◽  
Osama M. Darwesh ◽  
Pascal Habimana ◽  
Wei Liu ◽  
...  

2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Shinji Hayashi ◽  
Rieko Yagi ◽  
Shuhei Taniguchi ◽  
Masami Uji ◽  
Hidaka Urano ◽  
...  

AbstractCell-assisted lipotransfer (CAL) is an advanced lipoinjection method that uses autologous lipotransfer with addition of a stromal vascular fraction (SVF) containing adipose-derived stromal stem cells (ASCs). The CAL procedure of manual isolation of cells from fat requires cell processing to be performed in clean environment. To isolate cells from fat without the need for a cell processing center, such as in a procedure in an operation theater, we developed a novel method for processing SVF using a closed cell washing concentration device (CCD) with a hollow fiber membrane module. The CCD consists of a sterilized closed circuit, bags and hollow fiber, semi-automatic device and the device allows removal of >99.97% of collagenase from SVF while maintaining sterility. The number of nucleated cells, ASCs and viability in SVF processed by this method were equivalent to those in SVF processed using conventional manual isolation. Our results suggest that the CCD system is as reliable as manual isolation and may also be useful for CAL. This approach will help in the development of regenerative medicine at clinics without a cell processing center.


2021 ◽  
pp. 100135
Author(s):  
Shohre Tabibi ◽  
Mohsen Moussavi ◽  
Hadi Adlo

RSC Advances ◽  
2021 ◽  
Vol 11 (35) ◽  
pp. 21248-21258
Author(s):  
Di Zhang ◽  
Pengle Zhang ◽  
Du Xiao ◽  
Xiaogang Hao

Novel ion permselective membrane modules based on the ESIX scheme.


2019 ◽  
Vol 29 (10) ◽  
pp. 1346-1358 ◽  
Author(s):  
Sebastian Englart

This study discusses the use of a membrane module for semi-direct evaporative air cooling. A cross-flow membrane module was used to carry out this air treatment process. For such a flow, it was proposed to describe and solve the heat and mass transfer model as a one-dimensional problem. The mathematical model was used to determine the moisture content and air temperature at the outlet from the module and the temperature of the circulating water. Results obtained using the proposed model are in good agreement with the experimental data. The relative error for the air temperature at the module outlet did not exceed 0.5%. For the moisture content, the relative error did not exceed 4%. For the circulating water temperature, the relative error did not exceed 0.6%. This paper also discusses the heating efficiency of the evaporative cooling process. Methods for determining the unit cooling indicator and the energy efficiency ratio are also proposed.


Sign in / Sign up

Export Citation Format

Share Document