Malattached septum primum and deficient septal rim predict unsuccessful transcatheter closure of atrial communications

2015 ◽  
Vol 86 (7) ◽  
pp. 1195-1203 ◽  
Author(s):  
Stefan H. Ostermayer ◽  
Shubhika Srivastava ◽  
John T. Doucette ◽  
H. Helen Ko ◽  
Miwa Geiger ◽  
...  
2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Yoichi Takaya ◽  
Teiji Akagi ◽  
Koji Nakagawa ◽  
Rie Nakayama ◽  
Takashi Miki ◽  
...  

Background. Septal malalignment is related to erosion and device embolization in transcatheter closure of atrial septal defect (ASD), but limited information is available. Objectives. This study aimed to assess clinical significance of septal malalignment and to determine appropriate evaluation of ASD diameter, including the selection of device size. Methods. Four hundred and seventeen patients with ASD who underwent transcatheter closure were enrolled. Septal malalignment was defined as separation between the septum primum and the septum secundum on transesophageal echocardiography. Results. One hundred and eighty-four patients had septal malalignment. The frequency of septal malalignment increased with age reaching around 50% in adult patients. Septal malalignment was related to aortic rim deficiency. The distance of separation between the septum primum and the septum secundum was 5 ± 2 mm (range, 1–11 mm). In patients with septal malalignment, the ASD diameter measured at the septum primum was 19 ± 6 mm, while the ASD diameter measured at the septum secundum was 16 ± 6 mm. There was a difference of 4 ± 2 mm (range, 0–8 mm) between the ASD diameter measured at the septum primum and that measured at the septum secundum. For transcatheter closure, the Amplatzer Septal Occluder device size 2-3 mm larger and the Occlutech Figulla Flex II device size 4–7 mm larger than the ASD diameter measured at the septum primum were frequently used. During the study period, erosion or device embolization did not occur in all of the patients. Conclusions. Septal malalignment is highly prevalent in adult patients with aortic rim deficiency. The measurement of ASD diameter at the septum primum can be valuable for the selection of device size in patients with septal malalignment.


2020 ◽  
Vol 4 (5) ◽  
pp. 1-4
Author(s):  
Daniela Trabattoni ◽  
Sebastiano Gili ◽  
Giovanni Teruzzi ◽  
Gloria Tamborini

Abstract Background Transcatheter closure of patent foramen ovale (PFO) has been demonstrated to be superior to medical therapy in stroke prevention in selected patients. Beyond traditional permanent metallic devices, NobleStitch EL, a suture-based system, has been developed as a potential alternative. Case summary A 50-year-old man underwent transcatheter closure of PFO with mild interatrial septal bulging and tunnel-like morphology with a NobleStitch device. A transthoracic echocardiography performed immediately after PFO closure showed residual shunt (RS), which persisted unchanged at staged controls, due to the inability of the delivery system to capture both the septum primum and the septum secundum. A second procedure was performed with the implantation of a Figulla Flex II 27/30 mm device, with no RS detectable at control echocardiography. Discussion The NobleStitch device is interesting in its concept, but several pitfalls may be encountered during its deployment. Opposite to permanent metallic devices, RSs after the procedure are not expected to decrease over time and should be managed with a different approach.


2016 ◽  
Vol 19 (3) ◽  
pp. 145 ◽  
Author(s):  
Young Hwa Kong ◽  
Jinyoung Song ◽  
Kyung Hee Kim ◽  
June Huh ◽  
I-Seok Kang

<strong>Background:</strong> Acute changes in left ventricular diastolic function shortly after ASD closure in elderly patients have not been well known. We aimed to investigate acute changes in left ventricular end diastolic pressure (LVEDP) in elderly patients following transcatheter closure of atrial septal defect (ASD). <br /><strong>Methods:</strong> All 19 adults with ASDs who underwent transcatheter closure between June 2013 and December 2014 were enrolled. LVEDP was measured prior to device closure and compared with that immediately following device closure and 15 minutes after device closure. <br /><strong>Results:</strong> The median age of the patients was 48 years old. The baseline E/e’ and LVEDP values were 8.3 ± 2.8 and 13 ± 3 mmHg. The LVEDP value immediately following closure was 19 ± 4 mmHg, and 15 minutes after closure was 16 ± 4 mmHg. The median increase in the LVEDP value immediately following closure was 6 mmHg, which significantly differed from that prior to closure. The LVEDP 15 minutes after closure decreased but remained significantly higher than the value observed immediately after closure. No significant changes were observed with regard to E/e’ at either 1 day or 3 months following closure. The LVEDP value <br />15 minutes after device closure was significantly correlated with those observed before closure and immediately following closure; however, no significant correlations were observed with regard to patient age, Qp/Qs, E/e’ before closure, or E/e’ 3 months after device closure.<br /><strong>Conclusion:</strong> LVEDP in adults with ASDs significantly increases following device closure. LVEDP before closure predicts LVEDP following device closure.