Steady-state stability of interconnected power system taking into account the loading condition

1978 ◽  
Vol 98 (5) ◽  
pp. 68-74
Author(s):  
Shigenori Ohkubo ◽  
Syoichi Takeda ◽  
Katsuhiko Uemura
2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Kaiyuan Hou ◽  
Zeyu Li ◽  
Lei Chen ◽  
Deming Xia ◽  
Qun Li ◽  
...  

Coupled with the power system through power-electronic interfaces, renewable energies including wind power and photovoltaic can control the power quickly and flexibly. In the steady-state stability analysis, by neglecting the fast dynamics of power-electronic interfaces, the renewable energy power is simplified to a static power injection model and can be described as an algebraic equation in the dynamic process. Based on this simplified model, the steady-state stability of sending-end system with mixed synchronous generator and power-electronic-interfaced renewable energy is studied. By proposing a triangular transformation model based on the classical model of power system, the steady-state stability analysis becomes feasible. The mechanism of steady-state stability is revealed, and the influence of renewable energy on the steady-state stability limit is quantitatively investigated. When the renewable energy power increases, the steady-state stability limit of the sending-end system first increases and then decreases. Reducing the power output of synchronous generator can change for a higher integration limit of renewable energy. Simulation results validate the conclusion.


Author(s):  
Fredy Estuardo Tamayo Guzmán ◽  
Carlos Andrés Barrera-Singaña

Electrical power systems are exposed to several events that can cause unstable operation scenarios. This is due to improper operation of certain components. If an event occurs, the system must be designed to overcome that contingency, thus remaining in a permanent condition that must be evaluated in order to monitor and prevent a possible collapse of the system. An evaluation of steady state stability is proposed at this work based on the capacity curves of generators, transformers and transmission lines. These remarked curves provide information on the operation point of these elements, thus allowing the application of remedial actions. PowerFactory and Matlab are used to carry out the tool for monitoring the operation points after a contingency. The effectiveness of the developed tool is validated at the IEEE 39-bus power system model, where results shows that the functionalaty for different contingencies based on the operating conditions when the components of the power system are varied, cosnquently, the tool identifies cases that require actions at the operational level.


1967 ◽  
Vol 6 (3) ◽  
pp. 241-248 ◽  
Author(s):  
V. V. S. SARMA ◽  
B. L. DEEKSHATULU ◽  
H. N. RAMACHANDRA RAO

2019 ◽  
Vol 11 (24) ◽  
pp. 6908 ◽  
Author(s):  
Veerapandiyan Veerasamy ◽  
Noor Izzri Abdul Wahab ◽  
Rajeswari Ramachandran ◽  
Arangarajan Vinayagam ◽  
Mohammad Lutfi Othman ◽  
...  

This paper proposes a new population-based hybrid particle swarm optimized-gravitational search algorithm (PSO-GSA) for tuning the parameters of the proportional-integral-derivative (PID) controller of a two-area interconnected dynamic power system with the presence of nonlinearities such as generator rate constraints (GRC) and governor dead-band (GDB). The tuning of controller parameters such as Kp, Ki, and Kd are obtained by minimizing the objective function formulated using the steady-state performance indices like Integral absolute error (IAE) of tie-line power and frequency deviation of interconnected system. To test the robustness of the propounded controller, the system is studied with system uncertainties, such as change in load demand, synchronizing power coefficient and inertia constant. The two-area interconnected power system (TAIPS) is modeled and simulated using Matlab/Simulink. The results exhibit that the steady-state and transient performance indices such as IAE, settling time, and control effort are impressively enhanced by an amount of 87.65%, 15.39%, and 91.17% in area-1 and 86.46%, 41.35%, and 91.04% in area-2, respectively, by the proposed method compared to other techniques presented. The minimum control effort of PSO-GSA-tuned PID controller depicts the robust performance of the controller compared to other non-meta-heuristic and meta-heuristic methods presented. The proffered method is also validated using the hardware-in-the-loop (HIL) real-time digital simulation to study the effectiveness of the controller.


Sign in / Sign up

Export Citation Format

Share Document