Study on fire smoke flow characteristics in the ventilation network and linkage control system in coal mines

2020 ◽  
Vol 44 (7) ◽  
pp. 989-1003
Author(s):  
Kai Wang ◽  
Haiqing Hao ◽  
Shuguang Jiang ◽  
Zhengyan Wu ◽  
Weiyao Cai ◽  
...  
2011 ◽  
Vol 368-373 ◽  
pp. 1182-1185
Author(s):  
Chan Juan Xu ◽  
Shu Ping Zhang ◽  
Jing Jing Zhang

To a large comprehensive convention center as an example, this paper analyses the flow characteristics of fire smoke of the main hall and the feasibility for sharing space as "Quasi safety zone". First, the fire scenario was identified through the fire hazard analysis, then, set a model and take a simulation analysis by fire simulation software FDS, based on this fire scenario which have been established. At last, draw conclusions according to the smoke flow properties.


2019 ◽  
Vol 43 (7) ◽  
pp. 857-867 ◽  
Author(s):  
Zhisheng Xu ◽  
Qiulin Liu ◽  
Lu He ◽  
Haowen Tao ◽  
Jiaming Zhao ◽  
...  

2012 ◽  
Vol 226-228 ◽  
pp. 1472-1475
Author(s):  
Pei Pei Yang ◽  
Xiao Lu Shi ◽  
Bi Ming Shi

Once the tunnel fires happened, it will cause a major accident. And the smoke control of the runnel is important to fire prevention. A numerical simulation of the fire smoke flow in the tunnel model is presented by using FDS. The influence of different longitudinal ventilation on fire smoke flow of tunnel is obtained. And providing theory basis for tunnel ventilation system design, smoke spread control and safety evacuation. The results shown that in order to avoid reverse-flow and extend the time of smoke at the top of tunnel, the longitudinal speed should be controlled in 3.4 m/s; because of the role of longitudinal ventilation, smoke flow resistance and longitudinal ventilation generated by the effect of smoke flow resistance make the gas temperature first rise and then down.


2014 ◽  
Vol 513-517 ◽  
pp. 2635-2638
Author(s):  
Xuan Wei Peng

The corridor is an important way of evacuation and rescue in building fire. The fire smoke flow prediction software developed successfully was applied to simulate a building with a 28.8 meters long corridor to investigate the effect of the different thermal insulation on fire smoke spread rate. Two representative thermal insulation, external insulation and internal insulation were compared. In 3600s fire time, air temperature in the corridor of external insulation is much lower than that of internal insulation. The air temperature gap gets narrowed between the two insulation methods in the corridor with the prolongation of fire time. Temperature difference increases as the distance increase from the fire ignition place. The corridor gets unsafe of internal insulation in 7 minute since fire ignition, while about half the length of the corridor stay secure of external insulation in 10 minutes since fire ignition. That implies more available safe egress time can be gained with external insulation than internal insulation. Smoke spread rate was numerically compared based on the air temperature variation. Smoke spread rate of internal insulation is much higher than that of external insulation and the corresponding ratio is 1.732:1.


2011 ◽  
Vol 250-253 ◽  
pp. 3098-3102
Author(s):  
Hong Ming Fan ◽  
Kai Yuan He ◽  
Dan Zhang ◽  
Zhi Fang Yin

Rail transit hub is key node in urban transportation system. The study on properties of ventilation and smoke control system can improve response ability in case of fire and give ventilation and smoke control design guidance for underground rail transit hub. Take Beijing DongZhimen underground rail transit hub as research object, according to its air turbulent flow characteristics, introducing standard turbulence model based on the N-S equation. Build the computational fluid dynamics model for solving the flow field within underground rail transit hub. Through theoretical analysis and numerical simulation, take "Siamese model” results as the boundary condition and establish a mathematical model of rail transit hub with CFX. Then research fire smoke development and spread laws when the exhaust fan within underground rail transit hub delayed open.


2019 ◽  
Vol 37 (3) ◽  
pp. 213-235
Author(s):  
Yanqiu Chen ◽  
Dong Wang ◽  
Junmin Chen

Heat transfer and smoke flow filling progress in a super-high atrium is studied in this article. The influences of heat release rate and fire source height were considered. It was found that the fire smoke layer could not reach the top of the atrium when the heat release rate was very low and the fire source was located at the bottom of the atrium. The temperature of smoke layer interface and Δ Tmax were linearly positively related to Q2/3, while Δ Pmax was quadratically positively related to Q2/3. At the top of the atrium, the temperature rise and fire source height were consistent with the Boltzmann model. As the fire smoke rose with a velocity, a relatively low-pressure area was generated below. The pressure variation in this area was negatively index-related to the fire source height.


Author(s):  
Jan Babjak ◽  
Petr Novak ◽  
Tomas Kot ◽  
Wojciech Moczulski ◽  
Marek Adamczyk ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document