scholarly journals The Effect of Subway Tunnel Section Shape on the Moving Train Fire Smoke Flow Characteristics

Author(s):  
HUI YUAN ◽  
DAN ZHOU
2011 ◽  
Vol 368-373 ◽  
pp. 1182-1185
Author(s):  
Chan Juan Xu ◽  
Shu Ping Zhang ◽  
Jing Jing Zhang

To a large comprehensive convention center as an example, this paper analyses the flow characteristics of fire smoke of the main hall and the feasibility for sharing space as "Quasi safety zone". First, the fire scenario was identified through the fire hazard analysis, then, set a model and take a simulation analysis by fire simulation software FDS, based on this fire scenario which have been established. At last, draw conclusions according to the smoke flow properties.


2020 ◽  
Vol 44 (7) ◽  
pp. 989-1003
Author(s):  
Kai Wang ◽  
Haiqing Hao ◽  
Shuguang Jiang ◽  
Zhengyan Wu ◽  
Weiyao Cai ◽  
...  

2019 ◽  
Vol 43 (7) ◽  
pp. 857-867 ◽  
Author(s):  
Zhisheng Xu ◽  
Qiulin Liu ◽  
Lu He ◽  
Haowen Tao ◽  
Jiaming Zhao ◽  
...  

Author(s):  
Felipe Vittori ◽  
Luis Rojas-Solo´rzano ◽  
Armando J. Blanco ◽  
Rafael Urbina

This work deals with the numerical (CFD) analysis of the smoke propagation during fires within closed environments. It is evaluated the capacity of the emergency ventilation system in controlling the smoke propagation and minimizing the deadly impact of an eventual fire in a wagon within the Metro de Caracas subway tunnel on the passengers safety. For the study, it was chosen the tunnel section between Teatros and Nuevo Circo subway stations, which consists of two parallel independent twin tunnels, connected through a transverse passage. The tunnels are provided by a longitudinal ventilation system, integrated by a set of reversible fans located at both ends of the tunnels. Three stages were considered in the study: (a) Model set up; (b) Mesh sensitivity analysis; (c) Validation of the physical-numerical parameters to be used in the numerical model; and (d) Simulation of fire scenarios in Metro de Caracas subway stations. Stages (b)–(c), aimed to testing and calibrating the CFD tool (ANSYS-CFX10™), focused on reproducing experimental data from Vauquelin and Me´gret [1], who studied the smoke propagation in a fire within a 1:20 scale road tunnel. Stage (d) critical scenarios were established via a preliminary discussion with safety experts from Metro de Caracas, in order to reduce the computer memory and the number of simulations to be performed. The analyses assessed the reliability of escape routes and alternative paths for the evacuation of passengers. Additionally, the smoke front movement was particularly computed, as a function of time, in order to determine the possible presence of the “backlayering” phenomenon [5]. Results demonstrate the strengths and weaknesses of the current ventilation system in the event of a fire in the subway tunnel, and suggest new strategies to address this potentially lethal event to minimize the risks for passengers.


2012 ◽  
Vol 226-228 ◽  
pp. 1472-1475
Author(s):  
Pei Pei Yang ◽  
Xiao Lu Shi ◽  
Bi Ming Shi

Once the tunnel fires happened, it will cause a major accident. And the smoke control of the runnel is important to fire prevention. A numerical simulation of the fire smoke flow in the tunnel model is presented by using FDS. The influence of different longitudinal ventilation on fire smoke flow of tunnel is obtained. And providing theory basis for tunnel ventilation system design, smoke spread control and safety evacuation. The results shown that in order to avoid reverse-flow and extend the time of smoke at the top of tunnel, the longitudinal speed should be controlled in 3.4 m/s; because of the role of longitudinal ventilation, smoke flow resistance and longitudinal ventilation generated by the effect of smoke flow resistance make the gas temperature first rise and then down.


2014 ◽  
Vol 513-517 ◽  
pp. 2635-2638
Author(s):  
Xuan Wei Peng

The corridor is an important way of evacuation and rescue in building fire. The fire smoke flow prediction software developed successfully was applied to simulate a building with a 28.8 meters long corridor to investigate the effect of the different thermal insulation on fire smoke spread rate. Two representative thermal insulation, external insulation and internal insulation were compared. In 3600s fire time, air temperature in the corridor of external insulation is much lower than that of internal insulation. The air temperature gap gets narrowed between the two insulation methods in the corridor with the prolongation of fire time. Temperature difference increases as the distance increase from the fire ignition place. The corridor gets unsafe of internal insulation in 7 minute since fire ignition, while about half the length of the corridor stay secure of external insulation in 10 minutes since fire ignition. That implies more available safe egress time can be gained with external insulation than internal insulation. Smoke spread rate was numerically compared based on the air temperature variation. Smoke spread rate of internal insulation is much higher than that of external insulation and the corresponding ratio is 1.732:1.