Pathway based prognostic gene expression profile of buccal and gingivo-buccal oral squamous cell carcinoma in smokeless tobacco chewers

Head & Neck ◽  
2018 ◽  
Author(s):  
Kavitha Prasad ◽  
Roopa Rao ◽  
Dominic Augustine ◽  
Samudrala Venkatesiah Sowmya ◽  
Vanishri Haragannavar ◽  
...  
2005 ◽  
Vol 63 (6) ◽  
pp. 786-792 ◽  
Author(s):  
José Manuel Somoza-Martín ◽  
Abel García-García ◽  
Francisco Barros-Angueira ◽  
Eva Otero-Rey ◽  
María Torres-Español ◽  
...  

2011 ◽  
Vol 223 (4) ◽  
pp. 459-469 ◽  
Author(s):  
Kue Peng Lim ◽  
Nicola Cirillo ◽  
Yazan Hassona ◽  
Wenbin Wei ◽  
Johanna K Thurlow ◽  
...  

2004 ◽  
Vol 154 (1) ◽  
pp. 27-35 ◽  
Author(s):  
Gokce A. Toruner ◽  
Celal Ulger ◽  
Mualla Alkan ◽  
Anthony T. Galante ◽  
Joseph Rinaggio ◽  
...  

2011 ◽  
Vol 40 (4) ◽  
pp. 1180-1188 ◽  
Author(s):  
CAMILA OLIVEIRA RODINI ◽  
FLÁVIA CALÓ AQUINO XAVIER ◽  
KATIÚCIA BATISTA SILVA PAIVA ◽  
MARIA FERNANDA DE SOUZA SETÚBAL DESTRO ◽  
RAQUEL AJUB MOYSES ◽  
...  

2021 ◽  
Author(s):  
Sherri Borman ◽  
Jeff Wilkinson ◽  
Lauren Meldi-Sholl ◽  
Clare Johnson ◽  
Kelsey Carter ◽  
...  

Abstract Background To improve identification of patients with cutaneous squamous cell carcinoma (SCC) at high risk for metastatic disease, the DecisionDx-SCC assay, a prognostic 40-gene expression profile (40-GEP) test, was developed and validated. The 40-GEP assay utilizes RT-PCR gene expression analysis on primary tumor biopsy tissue to evaluate the expression of 34 signature gene targets and 6 normalization genes. The test provides classifications of low risk (Class 1), moderate risk (Class 2A), and high risk (Class 2B) of metastasis within 3 years of diagnosis. The primary objective of this study was to validate the analytical performance of the 40 gene expression signature. Methods The repeatability and reproducibility of the 40-GEP test was evaluated by performance of inter-assay, intra-assay, and inter-operator precision experiments along with monitoring the reliability of sample and reagent stability for class call concordance. The technical performance of clinical orders from September 2020 through July 2021 for the 40-GEP test was assessed. Results Patient hematoxylin and eosin (H&E) stained slides were reviewed by a board-certified pathologist to assess minimum acceptable tumor content. Class specific controls (Class 1 and Class 2B) were evaluated with Levey Jennings analysis and demonstrated consistent and reproducible results. Inter-assay, inter-operator and intra-assay concordance were all ≥90%, with short-term and long-term RNA stability also meeting minimum concordance requirements. Of the 2,446 orders received, 93.4% remained eligible for testing, with 96.8% of all tested samples that completed the assay demonstrating actionable class call results. Conclusion DecisionDx-SCC demonstrates a high degree of analytical precision, yielding high concordance rates across multiple performance experiments, along with exhibiting robust technical reliability on clinical samples.


Sign in / Sign up

Export Citation Format

Share Document