Homogeneous liquid‐liquid extraction as an alternative sample preparation technique for biomedical analysis

Author(s):  
Sherin F. Hammad ◽  
Inas A. Abdallah ◽  
Alaa Bedair ◽  
Fotouh R. Mansour
Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2277
Author(s):  
Piotr M. Kuś ◽  
Igor Jerković

Recently, we proposed a new sample preparation method involving reduced solvent and sample usage, based on dehydration homogeneous liquid–liquid extraction (DHLLE) for the screening of volatiles and semi-volatiles from honey. In the present research, the method was applied to a wide range of honeys (21 different representative unifloral samples) to determine its suitability for detecting characteristic honey compounds from different chemical classes. GC-FID/MS disclosed 130 compounds from different structural and chemical groups. The DHLLE method allowed the extraction and identification of a wide range of previously reported specific and nonspecific marker compounds belonging to different chemical groups (including monoterpenes, norisoprenoids, benzene derivatives, or nitrogen compounds). For example, DHLLE allowed the detection of cornflower honey chemical markers: 3-oxo-retro-α-ionols, 3,4-dihydro-3-oxoedulan, phenyllactic acid; coffee honey markers: theobromine and caffeine; linden honey markers: 4-isopropenylcyclohexa-1,3-diene-1-carboxylic acid and 4-(2-hydroxy-2-propanyl)cyclohexa-1,3-diene-1-carboxylic acid, as well as furan derivatives from buckwheat honey. The obtained results were comparable with the previously reported data on markers of various honey varieties. Considering the application of much lower volumes of very common reagents, DHLLE may provide economical and ecological advantages as an alternative sample preparation method for routine purposes.


Molecules ◽  
2018 ◽  
Vol 23 (7) ◽  
pp. 1769 ◽  
Author(s):  
Piotr Kuś ◽  
Igor Jerković

Qualitative chemical fingerprinting of the honey volatiles by gas chromatography and mass spectrometry (GC-MS) has been an efficient authentication tool that allowed for the classification of the honey botanical origin (strongly related to its medicinal and market value). However, the usage of current sample preparation methods is limited by selectivity of the volatiles extraction from the honey matrix and requires significant solvent volume. Therefore, a new sample preparation method based on dehydrating homogeneous liquid–liquid extraction (DHLLE) involving reduced solvent usage was developed for screening volatiles and semi-volatiles from the honey. The effective extraction was achieved by implementing a miscible liquid extraction system (aqueous honey solution/isopropanol) followed by separation through dehydration with MgSO4 and purification by a solvent polarity change and washing. The method was evaluated by estimating accuracy and precision. The DHLLE method showed satisfactory recoveries (75.2 to 93.5%) for typical honey volatiles: linalool, borneol, terpinen-4-ol, α-terpineol, p-anisaldehyde, eugenol, and vanillin. It also showed superior repeatability with percent relative standard deviation (RSD%) 0.8–8.9%. For benzyl alcohol, methyl syringate, and caffeine, the recoveries were 54.3 to 63.9% and 67.3 to 77.7% at lower and higher spiking levels, respectively. Applied to unifloral apple honey, the DHLLE method allowed for the identification of 40 compounds including terpenes, hydrocarbons, phenylpropanoids, and other benzene derivatives, which makes it suitable for fingerprinting and chemical marker screening. The obtained results were comparable or better than those obtained with ultrasonic extraction with dichloromethane.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
Pradip Sairam Pichumani ◽  
Fauzia Khatkhatay

Abstract Silicon photonics is a disruptive technology that aims for monolithic integration of photonic devices onto the complementary metal-oxide-semiconductor (CMOS) technology platform to enable low-cost high-volume manufacturing. Since the technology is still in the research and development phase, failure analysis plays an important role in determining the root cause of failures seen in test vehicle silicon photonics modules. The fragile nature of the test vehicle modules warrants the development of new sample preparation methods to facilitate subsequent non-destructive and destructive analysis methods. This work provides an example of a single step sample preparation technique that will reduce the turnaround time while simultaneously increasing the scope of analysis techniques.


Sign in / Sign up

Export Citation Format

Share Document