An irrigation system for noninvasively estimating intrarenal pressure during flexible ureteroscopy

Author(s):  
Xiongpeng Shu ◽  
Peng Hua ◽  
Le Xie
2010 ◽  
Vol 24 (12) ◽  
pp. 1915-1920 ◽  
Author(s):  
Yeung H. Ng ◽  
Bhaskar K. Somani ◽  
A. Dennison ◽  
S.G. Kata ◽  
Ghulam Nabi ◽  
...  

2020 ◽  
Author(s):  
Tengteng Wang ◽  
Xiude Chen ◽  
Qinghua Xia ◽  
Qi Zhang ◽  
Xunbo Jin

Abstract Background In recent years, the minimally invasive technique for treating nephrolithiasis has been developed rapidly. Particularly, the flexible ureteroscopy has been extensively applied. For flexible ureteroscopy lithotripsy, the perfusion equipment is necessary to ensure a clear intraoperative field of view. This study was aimed to prepare a set of economical and efficient ureteroscopic irrigation system by some commonly used devices in clinical diagnosis and treatment practice. Methods In this study, according to requirements of the endoscopic surgery, the infusion apparatus, infusion apparatus extension tube, three-way plug valve, Luer one-way valve, ordinary syringe, and negative pressure spring were used to assemble the irrigation system with different functions. Results The autonomous perfusion device realized the real-time conversion of manual injection, continuous perfusion or negative pressure suction. The entire equipment has many advantages, including easily accessible raw materials, low cost, simple assembly process, easy operation, strong controllability, effective control ability for the intrarenal pressure, and high safety. Conclusions The commonly used medical devices were applied to assemble the autonomous ureteroscopic irrigation system, which is flexible, simple and cost-effective and thus can be applied in flexible ureteroscopic surgery.


2018 ◽  
Vol 90 (3) ◽  
pp. 155-158 ◽  
Author(s):  
Salvatore Butticè ◽  
Bahadir Sahin ◽  
Tarik Emre Sener ◽  
Laurian Dragos ◽  
Silvia Proietti ◽  
...  

Introduction: Since 2012 Elmed has been working on a robot specifically designed for flexible ureteroscopy. After the first version of Avicenna Roboflex, a second version was developed in 2015, with significant changes especially in the irrigation system. We consider mandatory for the endourologist that works with the Avicenna Roboflex be aware of the functioning of the irrigation system. Materials and Methods: We connected a container to the pump’s irrigation system and measured the quantity of saline per second delivered by each speed setting, with/without the flush in five different modalities: pump on its own, pump with ureteroscope, with two laser fibers, with 1.9 Fr basket, and with a Terumo guidewire. Results: The highest mean flow-rates were observed in the 200- micrometer laser fiber, after the pump on its own. Median flowrates for all speed settings were significantly higher for the pump on its own than for the URS in both flushed and nonflushed modes (p = 0.045, p = 0.039 respectively). There was no statistically significant difference in median flow-rates between the guide wire and basket in all of the speed settings (p = 0.932 and p = 0.977). For both laser fibers there was no statistically significant difference between the median flow rate on both nonflush and flush modes. (p = 0.590 & p = 0.590). There was a linear correlation between the speed setting and the increase measured with the flush-option for pump only measurements (r = 0.602, p = 0.038). There was no statistically significant difference between laser fibers and the pump on its own on the increase of flow rate with flush mode. (p = 0.443 for the 272- micrometer fiber and p = 0.219 for the 200-micrometer fiber). Conclusion: The irrigation system of the new Avicenna Roboflex is optimized compared to the previous version. However other more complex studies concerning the live flow/pressure relationship are needed before firm conclusions can be made.


2006 ◽  
Vol 175 (4S) ◽  
pp. 333-333
Author(s):  
Michael E. Hoffman ◽  
Gary B. Johnson ◽  
Michael Grasso

2020 ◽  
Vol 0 (2) ◽  
pp. 21-25
Author(s):  
Nikolay Dubenok ◽  
Andrey Novikov ◽  
Sergei Borodychev ◽  
Maria Lamskova

At the stage of water treatment for irrigation systems, the efficiency capture coarse and fine mechanical impurities, as well as oil products and organic compounds affects the reliability of the equipment of the irrigation network and the safety of energy exchange processes in irrigated agricultural landscapes. The violation of work irrigation system can cause disruptions in irrigation schedules of agricultural crops, crop shortages, degradation phenomena on the soil and ecological tension. For the combined irrigation system, a water treatment unit has been developed, representing a hydrocyclone apparatus with a pipe filter in the case. For the capacity of 250 m3/h the main geometrical dimensions of hydrocyclone have been calculated. To organize the capture petroleum products and organic compounds, it has been proposed a modernization of a hydrocyclone unit, consisting in dividing the cylindrical part of the apparatus into two section. The first is section is for input irrigation water, the second one is for additional drainage of clarified irrigation water after sorption purification by the filter, placed on the disk and installed coaxially with the drain pipe and the pipe filter.


Author(s):  
S.M. Thomas ◽  
D. Bloomer ◽  
R.J. Martin ◽  
A. Horrocks

Applying water efficiently is increasingly important for dairy farmers and other users of surface and groundwater resources to maintain sustainable production. However, irrigation is rarely monitored. We used a questionnaire survey and measurements of five spray irrigation systems working in normal farm conditions to make observations on how efficiently irrigation is being managed. Survey results from 93 dairy farmers showed that, although the farmers believe they know how much water is being applied during irrigation, only 60% make measurements, and about 18% measure irrigation uniformity. Catch-can measurement of irrigation application depth for the different spray systems indicated large variability in application depths during irrigation, and field distribution uniformity ranged greatly between the different systems, decreasing in the order of centre pivots >travelling irrigators> K-line. Changes in irrigation system settings were sometimes made without considering application depths or uniformity. If our five case studies are typical, they may explain the large range of seasonal irrigation amounts recorded in the survey. We recommend that farmers monitor irrigation application depths and uniformity to help manage irrigation water efficiently and to help them estimate the value of irrigation to their enterprise. Keywords: distribution uniformity, water use efficiency, catch cans


Sign in / Sign up

Export Citation Format

Share Document