scholarly journals 3D printing of fetal heart using 3D ultrasound imaging data

2018 ◽  
Vol 52 (6) ◽  
pp. 808-809 ◽  
Author(s):  
S. A. Chen ◽  
C. S. Ong ◽  
N. Hibino ◽  
A. A. Baschat ◽  
J. R. Garcia ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2858
Author(s):  
Kelly Ka-Lee Lai ◽  
Timothy Tin-Yan Lee ◽  
Michael Ka-Shing Lee ◽  
Joseph Chi-Ho Hui ◽  
Yong-Ping Zheng

To diagnose scoliosis, the standing radiograph with Cobb’s method is the gold standard for clinical practice. Recently, three-dimensional (3D) ultrasound imaging, which is radiation-free and inexpensive, has been demonstrated to be reliable for the assessment of scoliosis and validated by several groups. A portable 3D ultrasound system for scoliosis assessment is very much demanded, as it can further extend its potential applications for scoliosis screening, diagnosis, monitoring, treatment outcome measurement, and progress prediction. The aim of this study was to investigate the reliability of a newly developed portable 3D ultrasound imaging system, Scolioscan Air, for scoliosis assessment using coronal images it generated. The system was comprised of a handheld probe and tablet PC linking with a USB cable, and the probe further included a palm-sized ultrasound module together with a low-profile optical spatial sensor. A plastic phantom with three different angle structures built-in was used to evaluate the accuracy of measurement by positioning in 10 different orientations. Then, 19 volunteers with scoliosis (13F and 6M; Age: 13.6 ± 3.2 years) with different severity of scoliosis were assessed. Each subject underwent scanning by a commercially available 3D ultrasound imaging system, Scolioscan, and the portable 3D ultrasound imaging system, with the same posture on the same date. The spinal process angles (SPA) were measured in the coronal images formed by both systems and compared with each other. The angle phantom measurement showed the measured angles well agreed with the designed values, 59.7 ± 2.9 vs. 60 degrees, 40.8 ± 1.9 vs. 40 degrees, and 20.9 ± 2.1 vs. 20 degrees. For the subject tests, results demonstrated that there was a very good agreement between the angles obtained by the two systems, with a strong correlation (R2 = 0.78) for the 29 curves measured. The absolute difference between the two data sets was 2.9 ± 1.8 degrees. In addition, there was a small mean difference of 1.2 degrees, and the differences were symmetrically distributed around the mean difference according to the Bland–Altman test. Scolioscan Air was sufficiently comparable to Scolioscan in scoliosis assessment, overcoming the space limitation of Scolioscan and thus providing wider applications. Further studies involving a larger number of subjects are worthwhile to demonstrate its potential clinical values for the management of scoliosis.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Xing Huang ◽  
Ni Fan ◽  
Hai-jun Wang ◽  
Yan Zhou ◽  
Xudong Li ◽  
...  

AbstractThe application of 3D printing in planning endoscopic endonasal transsphenoidal surgery is illustrated based on the analysis of patients with intracranial skull base diseases who received treatment in our department. Cranial computed tomography/magnetic resonance imaging data are attained preoperatively, and three-dimensional reconstruction is performed using MIMICS (Materialise, Leuven, Belgium). Models of intracranial skull base diseases are printed using a 3D printer before surgery. The models clearly demonstrate the morphologies of the intracranial skull base diseases and the spatial relationship with adjacent large vessels and bones. The printing time of each model is 12.52–15.32 h, and the cost ranges from 900 to 1500 RMB. The operative approach was planned in vitro, and patients recovered postoperatively well without severe complications or death. In a questionnaire about the application of 3D printing, experienced neurosurgeons achieved scores of 7.8–8.8 out of 10, while unexperienced neurosurgeons achieved scores of 9.2–9.8. Resection of intracranial skull base lesions is demonstrated to be well assisted by 3D printing technique, which has great potential in disclosing adjacent anatomical relationships and providing the required help to clinical doctors in preoperative planning.


Author(s):  
AA Gerasimova ◽  
LA Asyrafyan ◽  
IB Manuchin ◽  
MV Shamarakova ◽  
MS Miryasova ◽  
...  

Currently, surgical treatment aimed to exclude the malignant ovarian tumors is performed in almost 90% of patients with decidualized endometrial cysts (DEC). However, unnecessary surgical interventions increase the risk to maternal and fetal health. The study was aimed to perform a differential diagnosis of DEC in pregnant women in order to define the rational treatment. A total of 82 female patients were included in the study: 63 had endometrial cysts (EC), 16 had DEC, 3 had rare forms of endometriosis, and 10 had ovarian serous papillary borderline tumors. When performing the diagnostic ultrasound, our proposed model was used. The ultrasound imaging data obtained were juxtaposed with the concentration of the protein tumor markers (СА-125), the risk of malignancy index (RMI) was calculated, and the morphological assessment of the masses was performed. The ultrasound imaging parameters, being the most valuable for differential diagnosis of EC, DEC, and serous borderline tumors, were as follows: the altered mass wall thickness, the existence and shape of papillary masses, avascular echogenic inclusions with blurry contour, blood circulation and arrangement of blood vessels, ascites. The frequency analysis revealed the differences between groups based on the ultrasound imaging data (in 60–100% of observations). Histological examination revealed the differences between groups in 100% of observations. Our findings have made it impossible to prolong pregnancy in patients with DEC without performing surgery. The results of treatment provided to patients with DEC during pregnancy were worse compared to those in patients with no prominent decidualization in ovarian EC. Today, the diagnosis of DEC and the treatment of patients during pregnancy remain unsophisticated. Further clinical observation and the search for more reliable methods of the diagnosis and rational treatment of pregnant women with DEC are required.


2021 ◽  
Author(s):  
Nusrat Jahan Surovy

Ultrasound imaging is a widely used noninvasive imaging technique for biomedical and other applications. Piezoelectric devices are commonly used for the generation and detection of ultrasound in these applications. However, implementation of two-dimensional arrays of piezoelectric transducers for 3D ultrasound imaging is complex and expensive. Optical Fabry-Perot interferometry is an attractive alternative to the piezoelectric devices for detection of ultrasound. In this method a thin film etalon is constructed and used. Light reflected from the two surfaces of this thin film produces an intensity which depends on the film thickness. When ultrasound is incident on the film, it changes the thickness of the film and consequently modulates the light intensity on the film. In our work, we made two types of etalon (Finesse 2) for our experiment. We detected lower frequency ultrasound (0.5 MHz or 1 MHz) using the build etalon. We determined a linear relationship between the strength of the optical signals and the exerted pressure on a film by the ultrasound. The dependence of the etalon performance on the light wavelength was demonstrated indirectly by measuring the signal at various light incidence angle. Simulation results are also presented. Lastly, we proposed the optimum design of this detection system based on the simulation results. This method of ultrasound detection can be a potential low-cost approach for 3D ultrasound imaging.


Biomolecules ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 1577
Author(s):  
Zhonghua Sun

Three-dimensional (3D) printing has been increasingly used in medicine with applications in many different fields ranging from orthopaedics and tumours to cardiovascular disease. Realistic 3D models can be printed with different materials to replicate anatomical structures and pathologies with high accuracy. 3D printed models generated from medical imaging data acquired with computed tomography, magnetic resonance imaging or ultrasound augment the understanding of complex anatomy and pathology, assist preoperative planning and simulate surgical or interventional procedures to achieve precision medicine for improvement of treatment outcomes, train young or junior doctors to gain their confidence in patient management and provide medical education to medical students or healthcare professionals as an effective training tool. This article provides an overview of patient-specific 3D printed models with a focus on the applications in cardiovascular disease including: 3D printed models in congenital heart disease, coronary artery disease, pulmonary embolism, aortic aneurysm and aortic dissection, and aortic valvular disease. Clinical value of the patient-specific 3D printed models in these areas is presented based on the current literature, while limitations and future research in 3D printing including bioprinting of cardiovascular disease are highlighted.


Sign in / Sign up

Export Citation Format

Share Document