TECHNOLOGICAL TRANSFER. MINIATURE LASER MASS SPECTROMETER FOR EXPRESS ANALYSIS OF ENVIRONMENTAL SAMPLES

Author(s):  
LUBOMIR SIMEONOV ◽  
GEORGY MANAGADZE
2005 ◽  
Author(s):  
L. Fang ◽  
Y. Zhu ◽  
H. Y. Zheng ◽  
X. Y. Guo ◽  
W. W. Zhao ◽  
...  

1970 ◽  
pp. 29-36 ◽  
Author(s):  
F. J. Vastola ◽  
A. J. Pirone ◽  
P. H. Given ◽  
R. R. Dutcher

2005 ◽  
Vol 23 (4) ◽  
pp. 521-526 ◽  
Author(s):  
R.T. KHAYDAROV ◽  
G.R. BERDIYOROV ◽  
U. KUNISHEV ◽  
M. KHALMURATOV ◽  
E. TOJIKHONOV ◽  
...  

Characteristics of two-element (PbMg) laser generated plasma ions were studied using a mass-spectrometer. It was found that increasing the fraction of Mg leads to widening of the energy spectra of Pb ions by more than a factor of two, while the intensity of Pb ions of all charge states does not depend on the Mg fraction. This effect is explained by the friction existing between light and heavy ions during their expansion away from the target.


Author(s):  
S. P. Yarkov ◽  
I. V. Shilenko ◽  
S. N. Skopinskay ◽  
V. N. Zlobina

Immunochromatographic analysis with luminescent detection for indication of bacteria, viruses and toxins and apparatus for its carrying out were developed. The suggested approach is several times more sensitive as regards microorganisms and toxins detection than the traditional immunochromatographic analysis which is based on the reaction of antibodies marked by colloid gold. The set for immunochromatographic luminescent analysis (SIL-1) was offered on the basis of this elaboration. It can be considered as technical instrument for express analysis of environmental samples, for indication of biological affecting agents in case of emergency situations (terrorist attacks on transport and in populated area), for screening of mail, or facilitation of biopathogen identification after the stage of biological enrichment of selected samples.


Author(s):  
Zhiwen Wang ◽  
Huaibin Li ◽  
Chaohui He ◽  
Yaolin Zhao ◽  
Ning Chen ◽  
...  

129I is a long-lived (15.7M year) radioisotope of iodine. It can be used as a tracer for monitoring nuclear proliferation and the 129I/127I ratio can be used to evaluate the radiation contamination level. Nowadays a great number of nuclear power plants will be built in China, but the data of 129I concentration in environmental samples around nuclear power plants are limited. Accelerator Mass Spectrometer (AMS) whose detection limit is about 10−14, is one of the best instruments for analyzing environmental samples. The methods of making 129I target samples for AMS measurement from different type samples were studied, and the processing system for water and soil samples were established. Six surface seawater samples were collected at different distance away from a nuclear power plant in China. These samples were measured by Xi’an AMS. The ratios of 129I/127I in the seawater samples are between 0.829 × 10−10 and 9.451 × 10−10, and the average value is about 3.518 × 10−10. The ratios of 129I/127I in these samples are compared with other measurement results under different circumstances in other parts of the world. The results show that this nuclear power plant has not released superfluous 129I into environment after several years’ operation. Since the AMS and sample processing system are established, we will do much work on nuclear technology application with 129I tracer.