Dielectric Strength of Liquid Helium under Strongly Inhomogeneous Field Conditions

Author(s):  
M. M. Menon ◽  
S. W. Schwenterly ◽  
W. F. Gauster ◽  
R. H. Kernohan ◽  
H. M. Long
Author(s):  
S. W. Schwenterly ◽  
W. F. Gauster ◽  
R. H. Kernohan ◽  
H. M. Long ◽  
M. M. Menon

1961 ◽  
Vol 32 (12) ◽  
pp. 1400-1401 ◽  
Author(s):  
F. T. Stone ◽  
R. McFee

Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 1964 ◽  
Author(s):  
Stephanie Haegele ◽  
Farzaneh Vahidi ◽  
Stefan Tenbohlen ◽  
Kevin Rapp ◽  
Alan Sbravati

Due to the low biodegradability of mineral oil, intense research is conducted to define alternative liquids with comparable dielectric properties. Natural ester liquids are an alternative in focus; they are used increasingly as insulating liquid in distribution and power transformers. The main advantages of natural ester liquids compared to mineral oil are their good biodegradability and mainly high flash and fire points providing better fire safety. The dielectric strength of natural ester liquids is comparable to conventional mineral oil for homogeneous field arrangements. However, many studies showed a reduced dielectric strength for highly inhomogeneous field arrangements. This study investigates at which degree of inhomogeneity differences in breakdown voltage between the two insulating liquids occur. Investigations use lightning impulses with different electrode arrangements representing different field inhomogeneity factors and different gap distances. To ensure comparisons with existing transformer geometries, investigations are application-oriented using a transformer conductor model, which is compared to other studies. Results show significant differences in breakdown voltage from an inhomogeneity factor of 0.1 (highly inhomogeneous field) depending on the gap distance. Larger electrode gaps provide a larger inhomogeneity at which differences in breakdown voltages occur.


Author(s):  
R. E. Worsham ◽  
J. E. Mann ◽  
E. G. Richardson

This superconducting microscope, Figure 1, was first operated in May, 1970. The column, which started life as a Siemens Elmiskop I, was modified by removing the objective and intermediate lenses, the specimen chamber, and the complete vacuum system. The large cryostat contains the objective lens and stage. They are attached to the bottom of the 7-liter helium vessel and are surrounded by two vapor-cooled radiation shields.In the initial operational period 5-mm and 2-mm focal length objective lens pole pieces were used giving magnification up to 45000X. Without a stigmator and precision ground pole pieces, a resolution of about 50-100Å was achieved. The boil-off rate of the liquid helium was reduced to 0.2-0.3ℓ/hour after elimination of thermal oscillations in the cryostat. The calculated boil-off was 0.2ℓ/hour. No effect caused by mechanical or electrical instability was found. Both 4.2°K and 1.7-1.9°K operation were routine. Flux pump excitation and control of the lens were quite smooth, simple, and, apparently highly stable. Alignment of the objective lens proved quite awkward, however, with the long-thin epoxy glass posts used for supporting the lens.


Author(s):  
M.K. Lamvik ◽  
D.A. Kopf ◽  
S.D. Davilla ◽  
J.D. Robertson

Last year we reported1 that there is a striking reduction in the rate of mass loss when a specimen is observed at liquid helium temperature. It is important to determine whether liquid helium temperature is significantly better than liquid nitrogen temperature. This requires a good understanding of mass loss effects in cold stages around 100K.


2020 ◽  
Vol 47 (6) ◽  
pp. 789-792
Author(s):  
François R. Sylvestre ◽  
Beatriz P. Monteiro ◽  
Marie-Josée Simard ◽  
Paulo V. Steagall

Sign in / Sign up

Export Citation Format

Share Document