FEM Modelling and Thermography Validation of Thermal Flow

Author(s):  
Alicja Praczukowska ◽  
Michał Nowicki ◽  
Jakub Pełka
Keyword(s):  
Mathematics ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 756
Author(s):  
Federico Lluesma-Rodríguez ◽  
Francisco Álcantara-Ávila ◽  
María Jezabel Pérez-Quiles ◽  
Sergio Hoyas

One numerical method was designed to solve the time-dependent, three-dimensional, incompressible Navier–Stokes equations in turbulent thermal channel flows. Its originality lies in the use of several well-known methods to discretize the problem and its parallel nature. Vorticy-Laplacian of velocity formulation has been used, so pressure has been removed from the system. Heat is modeled as a passive scalar. Any other quantity modeled as passive scalar can be very easily studied, including several of them at the same time. These methods have been successfully used for extensive direct numerical simulations of passive thermal flow for several boundary conditions.


Molecules ◽  
2019 ◽  
Vol 24 (24) ◽  
pp. 4527 ◽  
Author(s):  
Saira Mumtaz ◽  
Mark J. Robertson ◽  
Michael Oelgemöller

An effective multi-step continuous flow approach towards N-diaminoalkylated 3-arylmethylene-2,3-dihydro-1H-isoindolin-1-ones, including the local anesthetic compound AL-12, has been realized. Compared to the traditional decoupled batch processes, the combined photochemical–thermal–thermal flow setup rapidly provides the desired target compounds in superior yields and significantly shorter reaction times.


2015 ◽  
Vol 651-653 ◽  
pp. 830-835
Author(s):  
Shohei Kajikawa ◽  
Riku Sakagami ◽  
Takashi Iizuka

Thermal flow tests were performed on steamed bamboo powder using capillaries that were processed under different conditions in order to investigate the effect of the die surface state on the fluidity of the woody powder. The capillaries were processed by wire-cut electric discharge machining, reaming or drilling, and the arithmetic average roughness (Ra) varied from 0.5 to 2.5 μm. The bamboo powder was first steamed at 200 °C for 20 min, and its particle size was then controlled using different mesh screens. The thermal flow temperature was set at 200 °C. The results indicated that the flow behavior improved with increasing particle size. For the capillaries processed by WEDM, the flow rate for samples with particle sizes of 75~150 and 150~300 μm decreased with increasing Ra. On the other hand, when reaming or drilling was used to process the capillaries, the flow rate was almost independent of Ra, regardless of the particle size.


Sign in / Sign up

Export Citation Format

Share Document