Hybrid Diesel/MCT/Battery Electricity Power Supply System for Power Management in Small Islanded Sites: Case Study for the Ouessant French Island

Author(s):  
Z. Zhou ◽  
M. E. H. Benbouzid ◽  
J. F. Charpentier ◽  
F. Scuiller
2013 ◽  
Vol 310 ◽  
pp. 413-416
Author(s):  
Pu Xie ◽  
Ren Xi Hu ◽  
Zheng Chun Liu

To construct a supervisory control platform for hybrid energy supplement power supply system, the constitution, functions of a power management system are proposed. Supervision and control system is founded based on KingView according to functional requirements and characteristic s of the power management system. Driving procedure of the KingView is written according to communication protocol of the data acquisition module at first Communication between PC and machine is achieved. Then, the running of equipments is simulated, and real-time date is monitored, showed, analyzed and processed. Then optimal management, coordinative control and seamless switching of hybrid energy supplement power supply system are achieved.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4781
Author(s):  
Szymon Haładyn

This article deals with the new challenges facing modernising railways in Poland. We look at the problem of the efficiency of the power supply system (3 kV DC) used in the context of the increasing use of electric vehicles, which have a higher demand for electricity than the old type. We present and characterise the power supply system in use, pointing out its weaknesses. We consider a case study. The load of the power supply network generated by the rolling stock used in Poland was examined using a microsimulation. A real train timetable was taken into account on a fragment of one of the most important railway line sections in one of the urban agglomerations. Then the results were compared with the results of a microsimulation in which old units were replaced by new trains. These tests were carried out in several variants. We found critical points in the scheduling of railway system use. Our results indicate that it is becoming increasingly necessary to take into account the permissible load capacity of the supply network in certain traffic situations in the process of timetable construction.


Author(s):  
Oladimeji Joseph Ayamolowo ◽  
Elutunji Buraimoh ◽  
Ayodeji Olalekan Salau ◽  
Joseph O. Dada

2013 ◽  
Vol 756-759 ◽  
pp. 4203-4206
Author(s):  
Zheng De Wang

A high performance power supply system was designed to meet the 1.5V power management, and it also provided 40A current for the load of four FPGA.The output power was 60W, the surface mount can effectively improve the efficiency, reduce the heat loss. In addition to providing power performance accurately, but also can improve the heat dissipation performance.


Sign in / Sign up

Export Citation Format

Share Document