Development and application of micro pressure-pickups to measure point-pressure of elastomer flow

Author(s):  
Shintaro Miyakawa ◽  
Takao Ishii
Keyword(s):  
2006 ◽  
Vol 175 (4S) ◽  
pp. 440-441
Author(s):  
Rodolfo B. Reis ◽  
Antonio A. Rodrigues ◽  
Adauto Cologna ◽  
Haylton J. Suaid ◽  
Antonio C.P. Martins ◽  
...  

2005 ◽  
Vol 173 (4S) ◽  
pp. 351-352
Author(s):  
Nilson A. Salas ◽  
George T. Somogyi ◽  
Bryce H. Vincent ◽  
Timothy B. Boone ◽  
Christopher P. Smith

2020 ◽  
Vol 6 (2) ◽  
pp. 50-58
Author(s):  
Matluba Muxammadiyeva ◽  
◽  
Iftixor Ergashev

If we look at the existing irrigation methods used today in the country, then they are divided into: ground, rainfall, underground or underground, drip and spray. Basically, they are transferred to the irrigation field in two forms: through gravity and pressure irrigation systems. Naturally, a gravity irrigation system is economically more expensive than a low pressure irrigation system. However, from a performance appraisal stand point, pressure irrigation methods are less efficient and have serious disadvantages


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kristine Janssen ◽  
Kangli Deng ◽  
Steve J. A. Majerus ◽  
Dan Li Lin ◽  
Brett Hanzlicek ◽  
...  

AbstractTransurethral and suprapubic catheterization have both been used to test urethral function in rats; however, it is unknown whether these methods affect urethral function or if the order of catheterization affects the results. The aim of this cross-over designed experiment was to compare the effects of catheterization methods and order on leak point pressure (LPP) testing. LPP and simultaneous external urethral sphincter electromyography (EUS EMG) were recorded in anesthetized female virgin Sprague-Dawley rats in a cross-over design to test the effects of transurethral and suprapubic catheterization. There was no significant difference in peak bladder pressure during LPP testing whether measured with a transurethral or suprapubic catheter. There was no significant difference in peak bladder pressure between the first and second catheter insertions. However, peak EMG firing rate, as well as peak EMG amplitude and EMG amplitude difference between peak and baseline were significantly higher after the first catheter insertion compared to the second insertion, regardless of the catheter method. Our results suggest that route of catheterization does not alter urethral function, e.g. create a functional partial outlet obstruction. Either catheterization method could be used for LPP and/or EUS EMG testing in rats.


2021 ◽  
pp. 152808372110326
Author(s):  
Queenie Fok ◽  
Joanne Yip ◽  
Kit-lun Yick ◽  
Sun-pui Ng

This study focuses on the fabrication of an anisotropic textile brace that exerts corrective forces based on the three-point pressure system to treat scoliosis, which is a medical condition that involves deformity of the spine. The design and material properties of the proposed anisotropic textile brace are discussed in detail here. A case series study with 5 scoliosis patients has been conducted to investigate the immediate in-brace effect and biomechanics of the proposed brace. Radiographic examination, three-dimensional scanning of the body and interface pressure measurements have been used to evaluate the immediate effect of the proposed brace on reducing the spinal curvature and asymmetry of the body contours and its biomechanics. The results show that the proposed brace on average reduces the spinal curvature by 11.7° and also increases the symmetry of the posterior trunk by 14.1% to 43.2%. The interface pressure at the corrective pad ranges from 6.0 to 24.4 kPa. The measured interface pressure shows that a sufficient amount of pressure has been exerted and a three-point pressure distribution is realized to reduce the spinal curvature. The obtained results indicate the effectiveness of this new approach which uses elastic textile material and a hinged artificial backbone to correct spinal deformity.


Sign in / Sign up

Export Citation Format

Share Document