Secondary Arc Current of UHVAC System

Author(s):  
Qiang Yi ◽  
Hao Zhou ◽  
Sha Li
Keyword(s):  
2020 ◽  
Vol 140 (11) ◽  
pp. 834-840
Author(s):  
Shogo Wada ◽  
Takamasa Hayasaka

1965 ◽  
Vol 43 (4) ◽  
pp. 670-675 ◽  
Author(s):  
B. Ahlborn ◽  
A. J. Barnard ◽  
H. D. Campbell

In a pulsed arc with mercury electrodes the average column field strength Eco was measured for different currents I, and the relationship [Formula: see text] was found. The variations of arc current and voltage with time indicate that the anode and cathode fall regions have a combined thickness of 3 × 10−6 cm, and an average field strength of 2 × 106 V/cm. The arc plasma is formed mainly from mercury vapor, rather than from the surrounding gas.


Author(s):  
Baina He ◽  
Yadi Xie ◽  
Jingru Zhang ◽  
Nirmal-Kumar C. Nair ◽  
Xingmin He ◽  
...  

Abstract In the transmission line, the series compensation device is often used to improve the transmission capacity. However, when the fixed series capacitor (FSC) is used in high compensation series compensation device, the stability margin cannot meet the requirements. Therefore, thyristor controlled series compensator (TCSC) is often installed in transmission lines to improve the transmission capacity of the line and the stability of the system. For cost considerations, the hybrid compensation mode of FSC and TCSC is often adopted. However, when a single-phase grounding fault occurs in a transmission line with increased series compensation degree, the unreasonable distribution of FSC and TCSC will lead to the excessive amplitude of secondary arc current, which is not conducive to rapid arc extinguishing. To solve this problem, this paper is based on 1000 kV Changzhi-Nanyang-Jingmen UHV series compensation transmission system, using PSCAD simulation program to established UHV series compensation simulation model, The variation law of secondary arc current and recovery voltage during operation in fine tuning mode after adding TCSC to UHV transmission line is analyzed, and the effect of increasing series compensation degree on secondary arc current and recovery voltage characteristics is studied. And analyze the secondary arc current and recovery voltage when using different FSC and TCSC series compensation degree schemes, and get the most reasonable series compensation configuration scheme. The results show that TCSC compensation is more beneficial to arc extinguishing under the same series compensation. Compared with several series compensation schemes, it is found that with the increase of the proportion of TCSC, the amplitude of secondary arc current and recovery voltage vary greatly. Considering various factors, the scheme that is more conducive to accelerating arc extinguishing is chosen.


2014 ◽  
Vol 986-987 ◽  
pp. 330-333
Author(s):  
Ding Jun Wen ◽  
Xiu Bin Zhang ◽  
Hong Gang Chen ◽  
Feng Jiang ◽  
Ya Ming Sun

The overvoltage calculation of 750kV transmission line with series compensation has great significance on the design, insulation coordination and protection of the line. In this paper, a transient model of 750kV power transmission system with series compensation is established. Effects of different capacity on no-load capacitive rise overvoltage, single-phase grounding overvoltage, two-phase grounding overvoltage are calculated. Secondary arc current and recovery voltage of different series compensation capacity in single-phase grounding is also calculated.


2010 ◽  
Vol 129-131 ◽  
pp. 692-696
Author(s):  
Jian Bing Meng ◽  
Xiao Juan Dong ◽  
Chang Ning Ma

A mathematical model was developed to describe the oscillating amplitude of the plasma arc injected transverse to an external transverse alternating magnetic field. The characteristic of plasma arc under the external transverse alternating magnetic field imposed perpendicular to the plasma current was discussed. The effect of processing parameters, such as flow rate of working gas, arc current, magnetic flux density and the standoff from the nozzle to the workpiece, on the oscillation of plasma arc were also analyzed. The results show that it is feasible to adjust the shape of the plasma arc by the transverse alternating magnetic field, which expands the region of plasma arc thermal treatment upon the workpiece. Furthermore, the oscillating amplitude of plasma arc decreases with decrease of the magnetic flux density. Under the same magnetic flux density, more gas flow rate, more arc current, and less standoff cause the oscillating amplitude to decrease. The researches have provided a deeper understanding of adjusting of plasma arc characteristics.


2014 ◽  
Vol 783-786 ◽  
pp. 1426-1431
Author(s):  
Wang Ryeol Kim ◽  
Min Chul Kwon ◽  
Jung Hoon Lee ◽  
Uoo Chang Jung ◽  
Won Sub Chung

TiAlSiN coatings were deposited on WC-Co metal by using a cathodic arc ion deposition method of cylindrical cathode. We used Ti / Al (50 / 50 at.%) arc target and silicon sputter target. The influence of the nitrogen pressure, TiAl cathode arc current, bias voltage, and deposition temperature on the mechanical and the structural properties of the films were investigated. The structural features of the films were investigation in detail using X-ray diffraction. And coatings were characterized by means of FE-SEM, nanoindentation, Scratch tester, Tribology tester, XRD and XPS. The hardness of the film reached 43 GPa at the cathode arc current of 230 A and decreased with a further increase of the arc current. And the adhesion of the film reached 34 N. The results showed that the TiAlSiN coating exhibited an excellent mechanical properties which application for tools and molds.


1992 ◽  
Vol 112 (1) ◽  
pp. 74-83 ◽  
Author(s):  
Yoshihisa Sekiya ◽  
Tatsuzo Hosokawa ◽  
Tadashi Morita ◽  
Shuichi Sugiyama ◽  
Yoku Mukaiyama ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document