CFD Simulation Research on Fluid Dynamics of Flotation Machines

Author(s):  
Zhengchang Shen
2013 ◽  
Vol 706-708 ◽  
pp. 1237-1240
Author(s):  
Xu Guang Sun ◽  
Chang Hai Wang ◽  
Cheng Long Feng ◽  
Kai Qiao

This paper presents a computational fluid dynamics (CFD) simulation research for the interior flow field of laminar cooling during hot strip mills. Based on analysis of the flow field, the interior model of cooling is designed precisely, and the result establishes foundation for improving the control precision of cooling control system.


Author(s):  
S N A Ahmad Termizi ◽  
C Y Khor ◽  
M A M Nawi ◽  
Nurlela Ahmad ◽  
Muhammad Ikman Ishak ◽  
...  

2013 ◽  
Vol 368-370 ◽  
pp. 599-602 ◽  
Author(s):  
Ian Hung ◽  
Hsien Te Lin ◽  
Yu Chung Wang

This study focuses on the performance of air conditioning design at the Dazhi Cultural Center and uses a computational fluid dynamics (CFD) simulation to discuss the differences in wind velocity and ambient indoor temperature between all-zone air conditioning design and stratified air conditioning design. The results have strong implications for air conditioning design and can improve the indoor air quality of assembly halls.


2016 ◽  
Vol 139 (1) ◽  
Author(s):  
S. Negin Mortazavi ◽  
Donna Geddes ◽  
Fatemeh Hassanipour

This study is a collaborative effort among lactation specialists and fluid dynamic engineers. The paper presents clinical results for suckling pressure pattern in lactating human breast as well as a 3D computational fluid dynamics (CFD) modeling of milk flow using these clinical inputs. The investigation starts with a careful, statistically representative measurement of suckling vacuum pressure, milk flow rate, and milk intake in a group of infants. The results from clinical data show that suckling action does not occur with constant suckling rate but changes in a rhythmic manner for infants. These pressure profiles are then used as the boundary condition for the CFD study using commercial ansys fluent software. For the geometric model of the ductal system of the human breast, this work takes advantage of a recent advance in the development of a validated phantom that has been produced as a ground truth for the imaging applications for the breast. The geometric model is introduced into CFD simulations with the aforementioned boundary conditions. The results for milk intake from the CFD simulation and clinical data were compared and cross validated. Also, the variation of milk intake versus suckling pressure are presented and analyzed. Both the clinical and CFD simulation show that the maximum milk flow rate is not related to the largest vacuum pressure or longest feeding duration indicating other factors influence the milk intake by infants.


2021 ◽  
Vol 2053 (1) ◽  
pp. 012013
Author(s):  
N. Abdul Settar ◽  
S. Sarip ◽  
H.M. Kaidi

Abstract Wells turbine is an important component in the oscillating water column (OWC) system. Thus, many researchers tend to improve the performance via experiment or computational fluid dynamics (CFD) simulation, which is cheaper. As the CFD method becomes more popular, the lack of evidence to support the parameters used during the CFD simulation becomes a big issue. This paper aims to review the CFD models applied to the Wells turbine for the OWC system. Journal papers from the past ten years were summarized in brief critique. As a summary, the FLUENT and CFX software are mostly used to simulate the Wells turbine flow problems while SST k-ω turbulence model is the widely used model. A grid independence test is essential when doing CFD simulation. In conclusion, this review paper can show the research gap for CFD simulation and can reduce the time in selecting suitable parameters when involving simulation in the Wells turbine.


2018 ◽  
Vol 24 (4) ◽  
pp. 369-378 ◽  
Author(s):  
J.N.M. Batista ◽  
R.C. Brito ◽  
R. Béttega

The spouted bed presents limitations in terms of scale-up. Furthermore, its stability depends on its geometry as well as the properties of the fluid and solid phases. CFD provides an important tool to improve understanding of these aspects, enabling a wide range of information to be obtained rapidly and at low cost. In this work, CFD simulation was used to evaluate the effects of different inlet air distributors (Venturi and straight tube) and the effects of static bed height on the fluid and solid dynamics of a conical spouted bed. Simulations were performed using the two-dimensional Euler-Euler approach. In order to evaluate the fluid dynamics model, static pressure data obtained by simulation were compared with experimental data obtained with the Venturi distributor. The fluid and solid dynamics of the conical spouted bed were obtained by CFD simulation. The results showed that the pressure drop was lower for the straight tube air distributor, while the Venturi air distributor provided higher stability and a more homogenous air distribution at the bed entrance.


2014 ◽  
Vol 11 (6) ◽  
Author(s):  
Paolo Sala ◽  
Paola Gallo Stampino ◽  
Giovanni Dotelli

This work is part of a project whose final aim is the realization of an auxiliary power fuel cell generator. It was necessary to design and develop bipolar plates that would be suitable for this application. Bipolar plates have a relevant influence on the final performances of the entire device. A gas leakage or a bad management of the water produced during the reaction could be determinant during operations and would cause the failure of the stack. The development of the bipolar plates was performed in different steps. First, the necessity to make an esteem of the dynamics that happen inside the feeding channels led to perform analytical calculations. The values found were cross-checked performing a computational fluid dynamics (CFD) simulation; finally, it was defined the best pattern for the feeding channels, so that to enhance mass transport and achieve the best velocity profile. The bipolar plates designed were machined and assembled in a laboratory scale two cells prototype stack. Influences of the temperature and of the humidity were evaluated performing experiments at 60 deg and 70 deg and between 60% and 100% of humidity of the reactant gasses. The best operating point achieved in one of these conditions was improved by modifying the flow rates of the reactant, in order to obtain the highest output power, and it evaluated the reliability of the plates in experiments performed for longer times, at fixed voltages.


Sign in / Sign up

Export Citation Format

Share Document