A quantitative method for estimating Pasquill stability class from windspeed and sensible heat flux density

1986 ◽  
Vol 37 (4) ◽  
pp. 357-369 ◽  
Author(s):  
Robert A. Sutherland ◽  
Frank V. Hansen ◽  
Walter D. Bach
2009 ◽  
Vol 10 (2) ◽  
pp. 479-492 ◽  
Author(s):  
G. O. Odhiambo ◽  
M. J. Savage

Abstract Measurements of sensible heat flux for an extended period for unstable conditions using surface layer scintillometry (SLS) and eddy covariance (EC) and supplemented by Bowen ratio measurements for a mixed grassland community on the eastern seaboard of South Africa are presented. Measurements of SLS sensible heat flux density were compared with those obtained using EC for a wide range of Bowen ratio (β). Also presented is an analysis of the different forms of the Monin–Obukhov similarity theory (MOST) functions used in micrometeorology and suggested by various authors, done by comparing EC sensible heat and measured by SLS through the use of an iterative determination of Monin–Obukhov parameters. A comparison of the SLS-measured structure parameter of air temperature CT2 corrected for β and uncorrected was carried out, with the results showing good correspondence but with a slight bias indicating that not correcting SLS measurements of CT2 for β would also result in a slight bias in H. Eddy covariance estimates of sensible heat flux density (HEC), obtained using averaging periods between 1 and 120 min and compared with scintillometer measurements, demonstrated that short-time averaging periods resulted in underestimated HEC. The EC measurements for 60- and 120-min averaging periods were sometimes inconsistent with SLS measurements. A sensitivity analysis indicates that both the EC and SLS measurements of H are influenced by β. For 0 < β < 0.2, the correction to HSLS amounts to more than 10% compared to more than 20% for HEC, although the magnitude of the differences are small. A comparison of HEC and HSLS measurements for 0.1 intervals of β between 0 and 4.3 shows reasonable correspondence for β > 1. For 0 < β < 1, the HSLS (y) versus HEC (x) scatterplot linear regression slope decreased from 1.25 to close to 1 for β increasing from 0 to 1. A comparison between β-corrected HEC and HSLS measurements—the latter computed using various empirical stability functions used by MOST—shows significant differences compared to HEC ranging from almost 20% overestimation for some methods to 20% underestimation for others. Long-term use of the recommended MOST stability functions for the SLS method is shown to result in reasonable correspondence between SLS and EC sensible heat flux for a wide range in atmospheric conditions, stability, and sensible heat magnitude.


Author(s):  
A. G. Korotkikh ◽  
◽  
V. A. Arkhipov ◽  
I. V. Sorokin ◽  
E. A. Selikhova ◽  
...  

The paper presents the results of ignition and thermal behavior for samples of high-energy materials (HEM) based on ammonium perchlorate (AP) and ammonium nitrate (AN), active binder and powders of Al, B, AlB2, and TiB2. A CO2 laser with a heat flux density range of 90-200 W/cm2 was used for studies of ignition. The activation energy and characteristics of ignition for the HEM samples were determined. Also, the ignition delay time and the surface temperature of the reaction layer during the heating and ignition for the HEM samples were determined. It was found that the complete replacement of micron-sized aluminum powder by amorphous boron in a HEM sample leads to a considerable decrease in the ignition delay time by a factor of 2.2-2.8 at the same heat flux density due to high chemical activity and the difference in the oxidation mechanisms of boron particles. The use of aluminum diboride in a HEM sample allows one to reduce the ignition delay time of a HEM sample by a factor of 1.7-2.2. The quasi-stationary ignition temperature is the same for the AlB2-based and AlB12-based HEM samples.


2019 ◽  
Vol 80 (3) ◽  
pp. 45-51
Author(s):  
L. Anatychuk ◽  
N. Pasyechnikova ◽  
V. Naumenko ◽  
O. Zadorozhnyy ◽  
R. Kobylianskyi ◽  
...  

1990 ◽  
Vol 36 (123) ◽  
pp. 217-221 ◽  
Author(s):  
Roger J. Braithwaite ◽  
Ole B. Olesen

AbstractDaily ice ablation on two outlet glaciers from the Greenland ice sheet, Nordbogletscher (1979–83) and Qamanârssûp sermia (1980–86), is related to air temperature by a linear regression equation. Analysis of this ablation-temperature equation with the help of a simple energy-balance model shows that sensible-heat flux has the greatest temperature response and accounts for about one-half of the temperature response of ablation. Net radiation accounts for about one-quarter of the temperature response of ablation, and latent-heat flux and errors account for the remainder. The temperature response of sensible-heat flux at QQamanârssûp sermia is greater than at Nordbogletscher mainly due to higher average wind speeds. The association of high winds with high temperatures during Föhn events further increases sensible-heat flux. The energy-balance model shows that ablation from a snow surface is only about half that from an ice surface at the same air temperature.


Sign in / Sign up

Export Citation Format

Share Document