Determination of cerium in rare earth ores by fluorescence quenching of rhodamine 6G

1997 ◽  
Vol 126 (1-2) ◽  
pp. 93-96 ◽  
Author(s):  
Nianqin Jie ◽  
Zhikun Si ◽  
Jinghe Yang ◽  
Qiang Zhang ◽  
Xirong Huang ◽  
...  
2013 ◽  
Vol 631-632 ◽  
pp. 18-21 ◽  
Author(s):  
Zhi Liang Jiang ◽  
Mei Ling Tang ◽  
Qing Ye Liu ◽  
Ai Hui Liang

In the condition of 1.24 mmol/L EDTANa2, 16.7 mmol/L NaCl and 0.17 mmol/L Tris, the substrate chain of double-stranded DNA (dsDNA) could be cracked by Pb2+ to release single-stranded DNA (ssDNA) that adsorb onto AuPd nanoparticle (AuPdNP) and form stable AuPdNP-ssDNA, but the dsDNA can not protect AuPdNP that were aggregated to big AuPdNP aggregations (AuPdNPA) under the action of NaCl. The AuPdNP-ssDNA and AuPdNPA could be separated by centrifugation. With the concentration of Pb2+ increased, the released ssDNA increased, the AuPdNP-ssDNA in centrifugation solution increased and the catalytic effect enhanced on the fluorescence quenching reaction of Rhodamine 6G (Rh6G) and NaH2PO2, which led the fluorescence intensity at 552nm to decrease. The decreased fluorescence intensity (ΔF552nm) was linear to the concentration of Pb2+ in the range of 0.33-8.00 nmol/L, a detection limit of 0.21 nmol/L. The proposed method was applied to detect Pb2+ in water samples, with satisfactory results.


2017 ◽  
Vol 84 (5) ◽  
pp. 900-905 ◽  
Author(s):  
Zh. Zhao ◽  
L. Sheng ◽  
B. Su ◽  
C. Tao ◽  
W. Jing

2013 ◽  
Vol 5 (7) ◽  
pp. 1843 ◽  
Author(s):  
Chunhua Ma ◽  
Liping Lin ◽  
Yanyan Du ◽  
Liang-bi Chen ◽  
Feng Luo ◽  
...  

2018 ◽  
Vol 84 (11) ◽  
pp. 9-14
Author(s):  
E. S. Koshel ◽  
V. B. Baranovskaya ◽  
M. S. Doronina

The analytical capabilities of arc atomic emission determination of As, Bi, Sb, Cu, Te in rare earth metals (REM) and their oxides after preparatory group concentration using S,N-containing heterochain polymer sorbent are studied on a high-resolution spectrometer “Grand- Extra” (“WMC-Optoelectron-ics” company, Russia). Sorption kinetics and dependence of the degree of the impurity extraction on the solution acidity are analyzed to specify conditions of sorption concentration. To optimize the procedure of arc atomic emission determination of As, Bi, Sb, Cu, and Te various schemes of their sorption preconcentration and subsequent processing of the resulted concentrate with the addition of a collector at different stages of the sorption process have been considered. Graphite powder is used as a collector in analysis of rare earth oxides due to universality and relative simplicity of the emission spectrum. Conditions of analysis and parameters of the spectrometer that affect the analytical signal (mass and composition of the sample, shape and size of the electrodes, current intensity and generator operation mode, interelectrode spacing, wavelengths of the analytical lines) are chosen. The evaporation curves of the determinable impurities were studied and the exposure time of As, Bi, Sb, Cu, and Te in the resulted sorption concentrate was determined. Correctness of the obtained results was evaluated using standard samples of the composition and in comparisons between methods. The results of the study are used to develop a method of arc chemical-atomic emission analysis of yttrium, gadolinium, neodymium, europium, scandium and their oxides in a concentration range of n x (10-2 - 10-5) wt.%.


2018 ◽  
Vol 17 (8) ◽  
pp. 2001-2009
Author(s):  
Tatjana Juzsakova ◽  
Akos Redey ◽  
Le Phuoc Cuong ◽  
Zsofia Kovacs ◽  
Tamas Frater ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document