Calculation of the filtration process when the filter medium resistance varies from cycle to cycle

1980 ◽  
Vol 16 (1) ◽  
pp. 33-37
Author(s):  
A. A. Grichenko ◽  
V. P. Abramov



1994 ◽  
Vol 29 (16) ◽  
pp. 2179-2196 ◽  
Author(s):  
G. G. Chase ◽  
J. Arconti ◽  
J. Kanel


Author(s):  
Fremmy Raymond Agustinus

Desain penyejuk udara juga dapat diterapkan di bidang kesehatan, dengan standar Cleanroom dapat diperoleh suhu, kelembaban, kenyamanan dan kebersihan yang dibutuhkan untuk ruang steril (ruang bedah). Perancangan pendingin udara dalam hal ini dilakukan dengan menentukan beban pendinginan yang diperlukan untuk ruang steril (ruang bedah), kemudian menentukan ukuran ducting, jalur ducting, dan jumlah penggunaan ducting. Desain ini menggabungkan unit split saluran yang dimodifikasi, kipas booster, filter pra, filter medium, dan filter HEPA dengan menggunakan saluran aluminium preinsulated sebagai saluran udara. Desain dilakukan dengan menggunakan perangkat lunak AutoCAD 2012, Design Tools Duct Sizer, dan Microsoft Excel. Dari hasil perhitungan dan desain didapatkan kebutuhan kapasitas 3 ruang bedah yaitu ducted ducted 100.000 BTUH sebanyak 3 unit, booster fan 3.3 - 4 Di WG sebanyak 3 unit, pre filter 24 "x 24" x 2 "6 set, filter menengah 610 x 610 x 290 mm 6 set, dan filter HEPA 1220 x 610 x 70 mm 12. Untuk ruang steril, tekanan statis yang dihasilkan oleh unit pendingin harus lebih besar daripada tekanan statis yang dihasilkan dari unit yang ada. di ruang semi steril. Dengan kata lain, ruang steril harus memiliki tekanan positif terhadap ruang semi steril. Hal ini dimaksudkan agar udara di ruang semi steril tidak masuk ke ruang steril ketika pintu antar ruangan dibuka. Desain dan perhitungan ruang bedah, suhu nyata yang diperoleh adalah 23 ° C ± 2 ° C dan kelembaban relatif yang diperoleh adalah 60% ± 2%.   Air conditioning design can also be applied in the health field, with cleanroom standard can be obtained temperature, humidity, comfort and hygiene needed for sterile room (surgical room). The design of air conditioning in this case is done by determining the cooling load required for the sterile room (surgical room), then determining the ducting size, ducting path, and the amount of ducting usage. This design combines modified ducted split unit, booster fan, pre filter, medium filter, and HEPA filter by using preinsulated aluminum duct as an air passage. The design is done by using AutoCAD 2012 software, Design Tools Duct Sizer, and Microsoft Excel. From the calculation and design result obtained the capacity requirement of 3 surgical room that is split ducted 100.000 BTUH as many as 3 units, booster fan 3.3 - 4 In WG as many as 3 units, pre filter 24"x 24" x 2" 6 sets, medium filter 610 x 610 x 290 mm 6 sets, and HEPA filter 1220 x 610 x 70 mm 12 sets. For the sterile room, the static pressure generated by the cooling unit shall be larger than the static pressure generated from the unit present in the semi sterile room. In other words, the sterile room must have positive pressure to the semi sterile room. It is intended that the air in the semi sterile room does not enter into the sterile room when the door between room opened. In this surgical room design and calculation, real temperature obtained is 23 °C ± 2 °C and the relative moisture obtained is 60% ± 2%.



Author(s):  
V.V. Neskoromnykh ◽  
◽  
M.S. Popova ◽  
A.V. Chikhotkin ◽  
A.E. Golovchenko ◽  
...  


1995 ◽  
Vol 32 (7) ◽  
pp. 199-206 ◽  
Author(s):  
Martin Oldenburg ◽  
Ivan Sekoulov

In this study the use of zeolites as ion-exchangers for equalization of ammonia peak loadings in aerated biological activated filters was investigated. For this use zeolites were mixed with a filter medium and the nitrifying filter was loaded with ammonia peaks for two hours at different flow rates. It could be demonstrated that during the phase of higher inflow concentrations the zeolite was collecting ammonia. When the influent concentration decreased ammonia was desorbed from the zeolite and could be nitrified by the bacteria growing on the filter medium. It was shown that additional zeolites can equalize variations of ammonia, especially in filter units which are working at a high nitrification rate and which are very sensitive to varying influent conditions. During the operation time of the filter no separation of the zeolite by higher hydraulic loading or by backwashing could be recognized. So the upgrading of nitrifying filters with zeolite represents an additional security for effluents containing oscillating ammonia concentrations.



2018 ◽  
pp. 99-107
Author(s):  
V. V. Lavrov ◽  
R. S. Luchkin ◽  
O. I. Nemykin ◽  
M. E. Prokhorov ◽  
Yu. G. Ryndin ◽  
...  

Methods and algorithms for the complete processing of a post-detector low-contrast optical image (OI) of an unknown remote object obtained by ground-based optical means of observation under conditions of a complex background situation are considered. The purpose of processing is to separate and interpret at least with the help of the analyst, of the main constructive elements using the integrated indicators introduced in [6] and the characteristics of the analyzed OI, which are connected by the information, topological and metric structures of the OI. The stages of processing the OI include extracting the image-containing information object of the image portion (detection) and filtration of the OI, using recursive rank filtering. The final stages of processing include the segmentation of the OI and the allocation on it constructive elements using the apparatus of graph theory. An example of image processing of a Spot-5 spacecraft obtained in real conditions is given. It is shown that in this case at the detection stage it is possible to reduce the volume of information processed at subsequent stages by 8 times, in the filtration process to increase the compactness of the OI and to increase its connectivity in comparison with the post-detection OI. As a result of segmentation and allocation of constructive elements, three structural elements that can be interpreted as a spacecraft case and two remote panels can be identified with the analyst’s participation.



2016 ◽  
Author(s):  
Jonathan Levy ◽  
◽  
Tedros Berhane ◽  
Mark P.S. Krekeler ◽  
Neil Danielson


2021 ◽  
Vol 1047 (1) ◽  
pp. 012042
Author(s):  
P A Kustashev ◽  
L A Kazakovtsev ◽  
I P Rozhnov ◽  
I N Kirikov ◽  
E P Burmistrov


Author(s):  
Rosiah Rohani ◽  
Izzati Izni Yusoff ◽  
Nadiah Khairul Zaman ◽  
Arshid Mahmood Ali ◽  
Nadiatul Atalia Balqis Rusli ◽  
...  


Sign in / Sign up

Export Citation Format

Share Document