Jaocs news feature: Collaborative study of the determination of total oil in sunflower seed

1974 ◽  
Vol 51 (2) ◽  
pp. 223A-223A ◽  
Author(s):  
James A. Robertson
1990 ◽  
Vol 73 (1) ◽  
pp. 54-57 ◽  
Author(s):  
Kurt Kolar

Abstract A colorimetric method for the determination of hydroxyproline as a measure of collagen in meat and meat products has been collaboratively studied in 18 laboratories. The method includes hydrolysis with sulfuric acid, oxidation with chloramine- T, and formation of a reddish purple complex with 4- dimethylaminobenzaldehyde. Five frozen and 3 freeze-dried samples were tested, ranging in content from 0.11 to 0.88% and from 0.39 to 4.0% hydroxyproline, respectively. The mean values of 2 identical samples were 0.245 and 0.251 %. The average recovery from a spiked sample was 96.1 %. The hydroxyproline content of a known sample (a mixture of 2 samples in the ratio 5:2) was calculated to 1.42%, which agrees well with the analytical result, 1.40%. In comparison with other collaborative studies, based on the ISO analytical method, the repeatability and reproducibility of this method agree well with the other results. This method was accepted as an official NMKL method by all national Committees, and has been adopted official first action by AOAC as an NMKLAOAC method.


1965 ◽  
Vol 48 (6) ◽  
pp. 1100-1103
Author(s):  
C H Mcbride

Abstract The atomic absorption method studied last year was re-examined and extended to include calcium and sodium. The procedures were submitted to 16 collaborators for determination of Ca, Cu, Fe, Mg, Mn, Na, and Zn. Results for Ca and Na were discouraging; further study is recommended.


1992 ◽  
Vol 75 (3) ◽  
pp. 395-416 ◽  
Author(s):  
Sungsoo C Lee ◽  
Leon Prosky ◽  
Jonathan W De Vries

Abstract A joint AOAC/AACC (American Association of Cereal Chemists) collaborative study of methods for the determination of soluble, insoluble, and total dietary fiber (SDF, IDF, and TDF) was conducted with 11 participating laboratories. The assay Is based on a modification of the AOAC TDF method 985.29 and the SDF/IDF method collaboratively studied recently by AOAC. The principles of the method are the same as those for the AOAC dietary fiber methods 985.29 and 991.42, Including the use of the same 3 enzymes (heat-stable α-amylase, protease, and amyloglucosldase) and similar enzyme Incubation conditions. In the modification, minor changes have been made to reduce analysis time and to Improve assay precision: (1) MES-TRIS buffer replaces phosphate buffer; (2) one pH adjustment step Is eliminated; and (3) total volumes of reaction mixture and filtration are reduced. Eleven collaborators were sent 20 analytical samples (4 cereal and grain products, 3 fruits, and 3 vegetables) for duplicate blind analysis. The SDF, IDF, and TDF content of the foods tested ranged from 0.53 to 7.17, 0.59 to 60.53, and 1.12 to 67.56 g/100 g, respectively. The respective average RSDR values for SDF, IDF, and TDF determinations by direct measurements were 13.1, 5.2, and 4.5%. The TDF values calculated by summing SDF and IDF were in excellent agreement with the TDF values measured independently. The modification did not alter the method performance with regard to mean dietary fiber values, yet It generated lower assay variability compared with the unmodified methods. The method for SDF, IDF, and TDF (by summing SDF and IDF) has been adopted first action by AOAC International.


1976 ◽  
Vol 59 (4) ◽  
pp. 807-810
Author(s):  
Jeffrey C Hamm

Abstract The USP analysis for procainamide HCl is titrimetric and relatively nonspecific, capsule and tablet dyes may interfere, and the method is not applicable to coated tablets. In the spectrophotofluorometric method the sample deteriorates when exposed to a xenon source. In the ultraviolet spectrophotometric method reported here, the sample is dispersed in acid medium, possible interferences are extracted in chloroform, base is added, procainamide is extracted in chloroform, the residue is dissolved in sodium hydroxide, and the compound is measured by absorption at 272 nm and comparison with a standard. Recoveries of standards added to capsule, tablet, and injection composites ranged from 99.3 to 102%. Twelve collaborators reported duplicate assay results for all 3 dosage forms with per cent standard deviations for 5 samples ranging from 1.01 to 1.27%. The method has been adopted as official first action.


1966 ◽  
Vol 49 (3) ◽  
pp. 511-515 ◽  
Author(s):  
R W Henningson

Abstract Bath level, sample temperature, rate of stirring, degree of supercooling, sample size, sample isolation, and refreezing of the sample were the variables in the thermistor cryoscopic method for the determination of the freezing point value of milk chosen for study. Freezing point values were determined for two samples of milk and two secondary salt standards utilizing eight combinations of the seven variables in two test patterns. The freezing point value of the salt standards ranged from –0.413 to –0.433°C and from –0.431 to –0.642°C. The freezing point values of the milk samples ranged from –0.502 to –0.544°C and from –0.518 to –0.550°C. Statistical analysis of the data showed that sample isolation was a poor procedure and that other variables produced changes in the freezing point value ranging from 0.001 to 0.011°C. It is recommended that specific directions be instituted for the thermistor cryoscopic method, 15.040–15.041, and that the method be subjected to a collaborative study.


1967 ◽  
Vol 50 (4) ◽  
pp. 847-849
Author(s):  
John Wiskerchen

Abstract A method is given for the quantitative determination of sodium lauryl sulfate in liquid, frozen, powdered, or flake-dried egg white. The egg white is dissolved in water and the protein is precipitated with ethanol and filtered off. The filtrate is evaporated, the residue is dissolved in water, and the pH is adjusted to 5.0. Total alkyl sulfates are titrated with standard benzethonium chloride solution in the presence of chloroform with bromphenol blue indicator. Results are calculated as sodium lauryl sulfate. The formation of the bromphenol bluebenzethonium chloride complex, when excess benzethonium chloride is present, is taken as the end point. The blue-green complex is soluble in the chloroform. Overall recoveries of sodium lauryl sulfate from egg whites ranged from 94 to 100%. Collaborative study of the method is recommended.


1998 ◽  
Vol 81 (4) ◽  
pp. 763-774 ◽  
Author(s):  
Joanna M Lynch ◽  
David M Barbano ◽  
J Richard Fleming

Abstract The classic method for determination of milk casein is based on precipitation of casein at pH 4.6. Precipitated milk casein is removed by filtration and the nitrogen content of either the precipitate (direct casein method) or filtrate (noncasein nitrogen; NCN) is determined by Kjeldahl analysis. For the indirect casein method, milk total nitrogen (TN; Method 991.20) is also determined and casein is calculated as TN minus NCN. Ten laboratories tested 9 pairs of blind duplicate raw milk materials with a casein range of 2.42- 3.05℅ by both the direct and indirect casein methods. Statistical performance expressed in protein equivalents (nitrogen ⨯ 6.38) with invalid and outlier data removed was as follows: NCN method (wt%), mean = 0.762, sr = 0.010, SR = 0.016, repeatability relative standard deviation (RSDr) = 1.287℅, reproducibility relative standard deviation (RSDR) = 2.146%; indirect casein method (wt℅), mean = 2.585, repeatability = 0.015, reproducibility = 0.022, RSDr = 0.560℅, RSDR = 0.841; direct casein method (wt℅), mean = 2.575, sr = 0.015, sR = 0.025, RSDr = 0.597℅, RSDR = 0.988℅. Method performance was acceptable and comparable to similar Kjeldahl methods for determining nitrogen content of milk (Methods 991.20, 991.21,991.22, 991.23). The direct casein, indirect casein, and noncasein nitrogen methods have been adopted by AOAC INTERNATIONAL.


1964 ◽  
Vol 47 (3) ◽  
pp. 573-576
Author(s):  
D J Mitchell

Abstract The AOAC Roese-Gottlieb and Rapid Detergent (TeSa) methods for the determination of butterfat in pasteurized, homogenized milk and in chocolate milk were compared in a collaborative study. The results by the detergent method on both products were comparable to those by the Roese-Gottlieb method. The Babcock method gave low results on the homogenized milk.


Sign in / Sign up

Export Citation Format

Share Document