Electromigration in the presence of a temperature gradient: Experimental study and modelling

1988 ◽  
Vol 17 (5) ◽  
pp. 473-478 ◽  
Author(s):  
A. P. Schwarzenberger ◽  
C. A. Ross ◽  
J. E. Evetts ◽  
A. L. Greer
2021 ◽  
pp. 002029402110071
Author(s):  
Da Wang ◽  
Benkun Tan ◽  
Xie Wang ◽  
Zhenhao Zhang

The temperature distribution of the bridge and its thermal effect has always been an important issue for researchers. To investigate the temperature distribution and thermal stress in the steel-concrete composite bridge deck, a 1:4 ratio temperature gradient effect experimental study was carried out in this paper. First, a set of experimental equipment for laboratory temperature gradient loading was designed based on the principle of temperature gradient caused by solar radiation, the temperature gradient obtained from the measurements were compared with the specifications and verified by the FE method. Next, the loading of the steel-concrete composite deck at different temperatures was performed. The thermal stress response and change trend of the simply supported and continuously constrained boundary conditions under different temperature loads were analyzed. The experimental results show that the vertical temperature of steel-concrete composite bridge deck is nonlinear, which is consistent with the temperature gradient trend of specifications. The vertical temperature gradient has a great influence on the steel-concrete composite bridge deck under different constraints, and the extreme stress of concrete slab and steel beam is almost linear with the temperature gradient. Finally, some suggestions for steel-concrete composite deck design were provided based on the research results.


2020 ◽  
Vol 91 (3) ◽  
pp. 31102
Author(s):  
Aiqiang Chen ◽  
Xin Chen ◽  
Xinxin Miao ◽  
Jinghong Yin ◽  
Bin Liu

The evolution of an evaporating liquid on another nonmiscible fluid is important for many applications. An experimental study on the evaporation process of hexane lens on the surface of deionized water at different temperatures was carried out, and the surface temperature distribution characteristics and internal flow pattern evolution was analyzed. Results show that the surface temperature of hexane lens can be divided into two parts or three areas depending on the temperature of deionized water. The increasing temperature of deionized water gradually changes both vertical temperature gradient and radial temperature gradient inside hexane lens, and their competition determines the flow pattern inside the hexane lens. Flow along hexane edge caused by circumferential surface tension gradient forms a “low temperature channel” between the central low temperature region and the strong evaporation edge. The knowledge will benefit the fundamental understanding of evaporation characteristics of volatile droplets on a liquid surface.


Sign in / Sign up

Export Citation Format

Share Document