Design and experimental study on a new heat dissipation method for watch-phones

Author(s):  
Wenjie Zhou ◽  
Yong Li ◽  
Zhaoshu Chen ◽  
Yuying Yan ◽  
Hanyin Chen
2012 ◽  
Vol 197 ◽  
pp. 216-220
Author(s):  
Zhong Chao Zhao ◽  
Rui Ye ◽  
Gen Ming Zhou

To solve the cooling problem in modern electronic device, a kind of heat pipe radiator was designed and manufactured in this paper. The heat transfer performance of heat pipe radiator and its relationship with air velocity were investigated by experimental method. The experimental results show that the heat pipe radiator can meet the temperature requirement of electronic device with the power range from 40W to 160W. To keep the operational temperature of electronic device with power of 160W under 75°C,the air velocity should be keep at 1.7m/s. The heat dissipation performance of heat pipe radiator was enhanced with the air velocity increased from 0.2m/s to 1.7m/s.for the electronic equipment with power of 160W.


2018 ◽  
Vol 8 (10) ◽  
pp. 1889 ◽  
Author(s):  
Jie Chen ◽  
Hua Liang ◽  
Yun Wu ◽  
Biao Wei ◽  
Guangyin Zhao ◽  
...  

An experimental study was conducted to evaluate the anti-icing performance of NS-DBD plasma actuator under the conditions of airflow speed U = 65 m/s, ambient temperature T = −10 °C, liquid water content LWC = 0.5 g/m3, mean-volume diameter MVD = 25 μm, mainly to clarify the effect of pulse frequency and voltage amplitude of actuation on anti-icing performance. A NACA0012 airfoil model with a chord length of c = 280 mm was used in the tests. The NS-DBD plasma actuator was mounted at the front part of the airfoil. A FLIR infrared (IR) imager and CCD camera were used to record the anti-icing process of the NS-DBD plasma actuator. Two typical discharge conditions were selected for the anti-icing experiments. The first was HV-LF discharge, corresponding to discharge under higher voltage amplitude with lower pulse frequency; the second was LV-HF discharge, corresponding to discharge under lower voltage amplitude with higher pulse frequency. Results reveal that NS-DBD is a very promising method for anti-icing. With the same power consumption, the LV-HF discharge shows a better anti-icing performance compared to HV-LF discharge under the same icing conditions. In view of pulse duration and duty circle, combined with heat dissipation, it is suggested that there is a threshold frequency, corresponding to the voltage amplitude of electric actuation signal and the incoming flow condition, to achieve effective anti-icing performance.


2019 ◽  
Vol 163 ◽  
pp. 114330 ◽  
Author(s):  
Minqiang Pan ◽  
Xineng Zhong ◽  
Guanping Dong ◽  
Pingnan Huang

2016 ◽  
Vol 2016 (S2) ◽  
pp. S1-S22
Author(s):  
Dongkai Shangguan ◽  
Yao Jian Lin ◽  
Won Kyung Choi ◽  
Seng Guan Chow ◽  
Seung Wook Yoon

To meet the continued demand for form factor reduction and functional integration of electronic devices, WLP (Wafer Level Packaging) is an attractive packaging solution with many advantages in comparison with standard BGA (Ball Grid Array) packages. The advancement of fan-out WLP has made it a more promising solution as compared with fan-in WLP, because it can offer greater flexibility in enabling more IO's, multi-chips, heterogeneous integration and 3D SiP. In particular, eWLB (Embedded Wafer Level BGA) is a fan-out WLP solution which can enable applications that require higher I/O density, smaller form factor, excellent heat dissipation, and thin package profile, and it has the potential to evolve in various configurations with proven integration flexibility, process robustness, manufacturing capacity and production yield. It also facilitates integration of multiple dies vertically and horizontally in a single package without using substrates. For eWLB fan-out WLP, the structural design as well as selection of materials is very important in determining the process yield and long term reliability. Therefore it is necessary to investigate the key design factors affecting the reliability comprehensively. This work is focused on an experimental study on the chip-package interactions in eWLB fan-out WLP with multilayer RDL's. Standard JEDEC component and board level tests were carried out to investigate reliability, and both destructive and non-destructive analyses were performed to investigate potential structural defects. Warpage, die cracking and other failures were characterized through metrology measurements and electrical tests. Board assembly processes (including SMT, underfill, etc.) were also studied. The influence of materials and structural design on the package reliability will be demonstrated. Thermal characterization and thermo-mechanical simulation results will also be discussed.


Author(s):  
Yujing Sun ◽  
Jie Sun ◽  
Jianfeng Li

The objective of this study is to model the temperature distributions in milling analytically. In this article, previous research on heat generation and heat dissipation in the machining process was reviewed and then the temperature model in intermittent cutting with continuously varying chip thickness was established. The experimental study to measure cutting temperature in milling Ti6Al4V utilizing semi-artificial thermocouple was presented. The predicted and experimental results for milling process were presented and compared. The results showed that the proposed mathematical model could predict cutting temperature with high accuracy.


The objective of this work is the improvement of the heat dissipation and the cooling of electric motors intended for the traction of vehicles. Two ways of improvement are proposed. The first one consists in replacing the air surrounding the stator windings by resins of higher thermal conductivity. The second way consists in using the spray cooling technique to cool the hottest parts of electric motor, i.e. coil windings. The two solutions are tested independently and simultaneously. Results show that filling the coil windings with resin enables better heat dissipation in the case of basic cooling by free air convection. On the contrary, the lowest temperatures are obtained with traditional coil winding without resin and by using spray cooling. In that case, the liquid part of the spray may infiltrate inside the coil and the evaporation takes place at the hottest point.


2018 ◽  
Vol 55 (2) ◽  
pp. 501-511 ◽  
Author(s):  
Hussain Ahmed Tariq ◽  
Asif Israr ◽  
Yasir Imtiaz Khan ◽  
Muhammad Anwar

Sign in / Sign up

Export Citation Format

Share Document