Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength

2017 ◽  
Vol 26 (11) ◽  
pp. 2891-2897 ◽  
Author(s):  
Lukas Weiser ◽  
Gerd Huber ◽  
Kay Sellenschloh ◽  
Lennart Viezens ◽  
Klaus Püschel ◽  
...  
2018 ◽  
Vol 27 (8) ◽  
pp. 1964-1971 ◽  
Author(s):  
Lukas Weiser ◽  
Gerd Huber ◽  
Kay Sellenschloh ◽  
Lennart Viezens ◽  
Klaus Püschel ◽  
...  

Spine ◽  
1994 ◽  
Vol 19 (21) ◽  
pp. 2415-2420 ◽  
Author(s):  
Thomas L. Halvorson ◽  
Lee A. Kelley ◽  
Kevin A. Thomas ◽  
Thomas S. Whitecloud ◽  
Stephen D. Cook

2001 ◽  
Vol 1 (6) ◽  
pp. 402-407 ◽  
Author(s):  
Koichiro Okuyama ◽  
Eiji Abe ◽  
Tetsuya Suzuki ◽  
Yasuki Tamura ◽  
Mitzuho Chiba ◽  
...  

2020 ◽  
Vol 14 (3) ◽  
pp. 265-272
Author(s):  
Atsushi Ikeura ◽  
Taketoshi Kushida ◽  
Kenichi Oe ◽  
Yoshihisa Kotani ◽  
Muneharu Ando ◽  
...  

Study Design: Biomechanical study.Purpose: To assess the correlation between the computed tomography (CT) values of the pedicle screw path and screw pull-out strength.Overview of Literature: The correlation between pedicle screw pull-out strength and bone mineral density has been well established. In addition, several reports have demonstrated a correlation between bone mineral density and CT values. However, no previous biomechanical studies investigated the correlation between CT values and pedicle screw pull-out strength.Methods: Sixty fresh-frozen lumbar vertebrae from 6-month-old pigs were used. Before screw insertion, the CT values of the screw path were obtained for each sample. Specimens were then randomly divided into three equal groups. Each group had one of three pedicle screws inserted: 4.0-mm LEGACY (4.0-LEG), 4.5-mm LEGACY (4.5-LEG), or 4.5-mm SOLERA (4.5-SOL) (all from Medtronic Sofamor Danek Inc., Memphis, TN, USA). Each screw had a consistent 30-mm thread length. Axial pull-out testing was performed at a rate of 1.0 mm/min. Correlations between the CT values and pedicle screw pull-out strength were evaluated using Pearson’s correlation coefficient analysis.Results: The correlation coefficients between the CT values of the screw path and pedicle screw pull-out strength for the 4.0-LEG, 4.5-LEG, and 4.5-SOL groups were 0.836 (<i>p</i> <0.001), 0.780 (<i>p</i> <0.001), and 0.873 (<i>p</i> <0.001), respectively. Greater CT values were associated with greater screw pull-out strength.Conclusions: The CT values of the screw path were strongly positively correlated with pedicle screw pull-out strength, regardless of the screw type and diameter, suggesting that the CT values could be clinically useful for predicting pedicle screw pull-out strength.


2009 ◽  
Vol 11 (1) ◽  
pp. 28-33 ◽  
Author(s):  
Mario J. Cardoso ◽  
Anton E. Dmitriev ◽  
Melvin D. Helgeson ◽  
Frederick Stephens ◽  
Victoria Campbell ◽  
...  

Object Transpedicular instrumentation at C-7 has been well accepted, but salvage techniques are limited. Lamina screws have been shown to be a biomechanically sound salvage technique in the proximal thoracic spine, but have not been evaluated in the lower cervical spine. The following study evaluates the anatomical feasibility of lamina screws at C-7 as well as their bone-screw interface strength as a salvage technique. Methods Nine fresh-frozen C-7 cadaveric specimens were scanned for bone mineral density using dual energy x-ray absorptiometry. Prior to testing, all specimens were imaged using CT to obtain 1-mm axial sections. Caliper measurements of both pedicle width and laminar thickness were obtained. On the right side, pedicle screws were first inserted and then pulled out. Salvage intralaminar screws were inserted into the left lamina from the right spinous process/lamina junction and then pulled out. All screws were placed by experienced cervical spine surgeons under direct fluoroscopic visualization. Pedicle and lamina screws were 4.35- and 3.5-mm in diameter, respectively. Screws sizes were chosen based on direct and radiographic measurements of the respective anatomical regions. Insertional torque (IT) was measured in pounds per inch. Tensile loading to failure was performed in-line with the screw axis at a rate of 0.25 mm/sec using a MiniBionix II system with data recorded in Newtons. Results Using lamina screws as a salvage technique generated mean pullout forces (778.9 ± 161.4 N) similar to that of the index pedicle screws (805.3 ± 261.7 N; p = 0.796). However, mean lamina screw peak IT (5.2 ± 2.0 lbs/in) was significantly lower than mean index pedicle screw peak IT (9.1 ± 3.6 lbs/in; p = 0.012). Bone mineral density was strongly correlated with pedicle screw pullout strength (r = 0.95) but less with lamina screw pullout strength (r = 0.04). The mean lamina width measured using calipers (5.7 ± 1.0 mm) was significantly different from the CTmeasured mean lamina width (5.1 ± 0.8 mm; p = 0.003). Similarly, the mean pedicle width recorded with calipers (6.6 ± 1.1 mm) was significantly different from the CT-measured mean pedicle width (6.2 ± 1.3 mm; p = 0.014). The mean laminar width measured on CT at the thinnest point ranged from 3.8 to 6.8 mm, allowing a 3.5-mm screw to be placed without difficulty. Conclusions These results suggest that using lamina screws as a salvage technique at C-7 provides similar fixation strength as the index pedicle screw. The C-7 lamina appears to have an ideal anatomical width for the insertion of 3.5-mm screws commonly used for cervical fusions. Therefore, if the transpedicular screw fails, using intralaminar screws appear to be a biomechanically sound salvage technique.


2007 ◽  
Vol 7 (1) ◽  
pp. 47-53 ◽  
Author(s):  
Bruce M. Frankel ◽  
Sabino D'Agostino ◽  
Chiang Wang

Object Instrumentation of the osteoporotic spine can be fraught with complications such as hardware failure. A cadaver study was performed to determine the biomechanical performance of polymethylmethacrylate (PMMA)–augmented pedicle screws. Methods Three osteoporotic human cadaveric specimens with a mean bone mineral density of 0.70 g/cm2 were used to evaluate the performance of a novel fenestrated bone tap in pedicle screw augmentation. On this device, tap threads serve a dual purpose in preventing backflow of cement toward neural elements while allowing for a custom form for subsequent screw placement. The tap was used to inject a mean volume of 3.7 ml PMMA/pedicle (range 2–8.0 ml PMMA/pedicle) followed by pedicle screw placement between L-5 and T-5, alternating between augmented and nonaugmented instrumentation. Axial pullout testing was then performed. Results Pedicle screw pullout strength was increased in both primary and salvage procedures by 119% (p = 0.001) and 162% (p = 0.01), respectively, after PMMA augmentation. Additionally, the injected cement volumes were divided into two groups, a low-cement group (≤ 2.8 ml/pedicle) and a high-cement group (≥ 5.5 ml/pedicle). Interestingly, the pullout strength did not significantly change with increased cement usage between the two groups (p > 0.05 for all comparisons). Conclusions Polymethylmethacrylate-augmented pedicle screw fixation results in a significant increase in the axial pullout strength of augmented pedicle screws in both primary and revision procedures. This technique may be a valuable adjunct in cases in which bolstering of the screw–bone interface is necessary.


2020 ◽  
Vol 21 (1) ◽  
Author(s):  
Xuhong Xue ◽  
Sheng Zhao

Abstract Background The management of thoracolumbar burst fractures traditionally involves posterior pedicle screw fixation, but it has some drawbacks. The aim of this study is to evaluate the clinical and radiological outcomes of patients with thoracolumbar burst fractures. They were treated by a modified technique that monoaxial pedicle screws instrumentation and distraction-compression technology assisted end plate reduction. Methods From March 2014 to February 2016, a retrospective study including 42 consecutive patients with thoracolumbar burst fractures was performed. The patients had undergone posterior reduction and instrumentation with monoaxial pedicle screws. The fractured vertebrae were also inserted screws as a push point. The distraction -compression technology was used as assisting end plate reduction. All patients were followed up at a minimum of 2 years. These parameters including segmental kyphosis, severity of fracture, neurological function, canal compromise and back pain were evaluated in preoperatively, postoperatively and at the final follow-up. Results The average follow-up period was 28.9 ± 4.3 months (range, 24-39mo). No patients had postoperative implant failure at recent follow-up. The mean Cobb angle of the kyphosis was improved from 14.2°to 1.1° (correction rate 92.1%). At final follow-up there was 1.5% loss of correction. The mean preoperative wedge angle was improved from 17.1 ± 7.9°to 4.4 ± 3.7°(correction rate 74.3%). The mean anterior and posterior vertebral height also showed significant improvements postoperatively, which were maintained at the final follow-up(P < 0.05). The mean visual analogue scale (VAS) scores was 8 and 1.6 in preoperation and at the last follow-up, and there was significant difference (p < 0.05). Conclusion Based on our experience, distraction-compression technology can assist reduction of collapsed endplate directly. Satisfactory fracture reduction and correction of segmental kyphosis can be achieved and maintained with the use of monoaxial pedicle screw fixation including the fractured vertebra. It may be a good treatment approach for thoracolumbar burst fractures.


Sign in / Sign up

Export Citation Format

Share Document