Using lamina screws as a salvage technique at C-7: computed tomography and biomechanical analysis using cadaveric vertebrae

2009 ◽  
Vol 11 (1) ◽  
pp. 28-33 ◽  
Author(s):  
Mario J. Cardoso ◽  
Anton E. Dmitriev ◽  
Melvin D. Helgeson ◽  
Frederick Stephens ◽  
Victoria Campbell ◽  
...  

Object Transpedicular instrumentation at C-7 has been well accepted, but salvage techniques are limited. Lamina screws have been shown to be a biomechanically sound salvage technique in the proximal thoracic spine, but have not been evaluated in the lower cervical spine. The following study evaluates the anatomical feasibility of lamina screws at C-7 as well as their bone-screw interface strength as a salvage technique. Methods Nine fresh-frozen C-7 cadaveric specimens were scanned for bone mineral density using dual energy x-ray absorptiometry. Prior to testing, all specimens were imaged using CT to obtain 1-mm axial sections. Caliper measurements of both pedicle width and laminar thickness were obtained. On the right side, pedicle screws were first inserted and then pulled out. Salvage intralaminar screws were inserted into the left lamina from the right spinous process/lamina junction and then pulled out. All screws were placed by experienced cervical spine surgeons under direct fluoroscopic visualization. Pedicle and lamina screws were 4.35- and 3.5-mm in diameter, respectively. Screws sizes were chosen based on direct and radiographic measurements of the respective anatomical regions. Insertional torque (IT) was measured in pounds per inch. Tensile loading to failure was performed in-line with the screw axis at a rate of 0.25 mm/sec using a MiniBionix II system with data recorded in Newtons. Results Using lamina screws as a salvage technique generated mean pullout forces (778.9 ± 161.4 N) similar to that of the index pedicle screws (805.3 ± 261.7 N; p = 0.796). However, mean lamina screw peak IT (5.2 ± 2.0 lbs/in) was significantly lower than mean index pedicle screw peak IT (9.1 ± 3.6 lbs/in; p = 0.012). Bone mineral density was strongly correlated with pedicle screw pullout strength (r = 0.95) but less with lamina screw pullout strength (r = 0.04). The mean lamina width measured using calipers (5.7 ± 1.0 mm) was significantly different from the CTmeasured mean lamina width (5.1 ± 0.8 mm; p = 0.003). Similarly, the mean pedicle width recorded with calipers (6.6 ± 1.1 mm) was significantly different from the CT-measured mean pedicle width (6.2 ± 1.3 mm; p = 0.014). The mean laminar width measured on CT at the thinnest point ranged from 3.8 to 6.8 mm, allowing a 3.5-mm screw to be placed without difficulty. Conclusions These results suggest that using lamina screws as a salvage technique at C-7 provides similar fixation strength as the index pedicle screw. The C-7 lamina appears to have an ideal anatomical width for the insertion of 3.5-mm screws commonly used for cervical fusions. Therefore, if the transpedicular screw fails, using intralaminar screws appear to be a biomechanically sound salvage technique.

2020 ◽  
Vol 14 (3) ◽  
pp. 265-272
Author(s):  
Atsushi Ikeura ◽  
Taketoshi Kushida ◽  
Kenichi Oe ◽  
Yoshihisa Kotani ◽  
Muneharu Ando ◽  
...  

Study Design: Biomechanical study.Purpose: To assess the correlation between the computed tomography (CT) values of the pedicle screw path and screw pull-out strength.Overview of Literature: The correlation between pedicle screw pull-out strength and bone mineral density has been well established. In addition, several reports have demonstrated a correlation between bone mineral density and CT values. However, no previous biomechanical studies investigated the correlation between CT values and pedicle screw pull-out strength.Methods: Sixty fresh-frozen lumbar vertebrae from 6-month-old pigs were used. Before screw insertion, the CT values of the screw path were obtained for each sample. Specimens were then randomly divided into three equal groups. Each group had one of three pedicle screws inserted: 4.0-mm LEGACY (4.0-LEG), 4.5-mm LEGACY (4.5-LEG), or 4.5-mm SOLERA (4.5-SOL) (all from Medtronic Sofamor Danek Inc., Memphis, TN, USA). Each screw had a consistent 30-mm thread length. Axial pull-out testing was performed at a rate of 1.0 mm/min. Correlations between the CT values and pedicle screw pull-out strength were evaluated using Pearson’s correlation coefficient analysis.Results: The correlation coefficients between the CT values of the screw path and pedicle screw pull-out strength for the 4.0-LEG, 4.5-LEG, and 4.5-SOL groups were 0.836 (<i>p</i> <0.001), 0.780 (<i>p</i> <0.001), and 0.873 (<i>p</i> <0.001), respectively. Greater CT values were associated with greater screw pull-out strength.Conclusions: The CT values of the screw path were strongly positively correlated with pedicle screw pull-out strength, regardless of the screw type and diameter, suggesting that the CT values could be clinically useful for predicting pedicle screw pull-out strength.


2020 ◽  
Author(s):  
Sen Liu ◽  
Jia Li ◽  
Hong-Yang Gao ◽  
Wei Wang ◽  
Wei Dong ◽  
...  

Abstract Objectives The aim of this study is to explore the pullout strength of adjusting pedicle screw with or without self-bone grafting in the previous trajectory using an osteoporotic human vertebral body. Methods Thirty vertebrae from six cadavers were collected and all of the vertebrae were divided into two groups according to bone mineral density: control group with normal bone mineral density; osteoporosis group with osteoporosis. The osteoporosis group was randomly and evenly divided into five subsamples according to direction of reinsert pedicle screw: the normal angle, sagittal angle, sagittal bone grafting, horizontal angle, horizontal bone grafting. Axial pullout strength testing of the pedicle screw was performed and the maximum axial pullout force (Fmax) was applied to analyse. Result The bone mineral density of the control group was 1.115±0.065 g/cm3, and the bone mineral density of the osteoporosis group was 0.678±0.055 g/cm3, presenting significantly different between the two group (P<0.001). Compared with the control group, the Fmax of the normal angle group was smaller (600.64±43.10 vs 1100.74±49.08 N, P<0.001). Compared with the normal angle group, the Fmax of the sagittal angle group (339.13±38.90 vs 600.64±43.10 N, P<0.001) and the horizontal angle group (342.06±33.01 vs 600.64±43.10 N, P<0.001) were smaller. The Fmax in sagittal bone grafting group was higher than that with non-implanted bone in primary screw canal (492.30±42.06 vs 342.06±33.01 N, P<0.001), and the Fmax of the horizontal bone grafting group was higher than that with non-implanted bone in primary screw canal (502.02± 50.26 vs 342.06±33.01 N, P<0.001). Conclusion The pullout strength of adjusting pedicle screw is seriously decreased in osteoporotic human vertebral body and self-bone grafting in the previous trajectory is an effective remedial measure.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1340.1-1340
Author(s):  
E. Kirilova ◽  
N. Kirilov ◽  
S. Vladeva

Background:Radiofrequency Echographic Multi-Spectrometry (REMS) is a non-ionizing innovative approach for the assessment of REMS-based bone mineral density (BMD) of the axial skeleton. The principle of the REMS technology is based on the analysis of native raw unfiltered ultrasound signals during an echographic scan of the lumbar spine or the femoral neck [1]. Several studies demonstrated the high concordance with dual energy X-ray absorptiometry (DXA) in terms of measured BMD with this novel technology [2,3]. In previous published literature it was envisaged to apply this technology for the examination of the axial bone density in pregnant women. Pregnancy-associated bone loss has been demonstrated as decreased bone mineral density (BMD) in previous studies [4].Objectives:The aim of the current study is to compare the BMD values of both femora between pregnant and non-pregnant women matched for age and BMI using the novel REMS technology.Methods:Of total fifty women twenty pregnant women (40%) and thirty non-pregnant women (60%) were included in the study. The mean age of the pregnant women was 32 years ± 5 standard deviations (SD), (range 25-41 years) and the mean age of the non-pregnant women was 30 years ± 6 standard deviations (SD), (range 24-39 years). REMS approach was used to assess REMS-based BMD and REMS-based Z-score values of the femoral neck. Furthermore, body mass index (BMI) and gestational age in weeks were evaluated.Results:The mean BMI of the pregnant women was 26 kg/m2 ± 7 kg/m2 (range 14 kg/m2-42 kg/m2) and those of the non-pregnant women was 25 kg/m2 ± 5 kg/m2 (range 16 kg/m2-35 kg/m2). The mean gestational age was 20 weeks’ gestation ± 5 weeks’ gestation (range 13-27 weeks’ gestation). REMS-based mean BMD of the left femoral neck of the pregnant women was 0.793 g/cm2 ± 0.167 g/cm2 (range 0.563 g/cm2-1.154 g/cm2). REMS-based mean BMD of the right femoral neck of the pregnant women was 0.828 g/cm2 ± 0.153 g/cm2 (range 0.570 g/cm2-1.161 g/cm2). After comparing left femoral neck BMD with the right femoral neck BMD of the pregnant women, we found a linear correlation (R=0.764). Left femoral neck BMD value (0.793 g/cm2) of the pregnant women was significantly lower than those of the non-pregnant women (0.854 g/cm2), p=0.002. The mean left femoral Z-score of the pregnant women (-0.1 SD with range -2.5 SD-2.9 SD) was also significantly lower compared to those of the non-pregnant women (1.2 SD with range -1.5 SD-3.1 SD), p=0.003.Conclusion:This is the first study which provides data about BMD and Z-score values of both femora in pregnant women assessed with the radiation-free REMS technology. Pregnant women demonstrated significantly lower femoral neck BMD values and Z-scores compared to those of the non-pregnant women. Innovative REMS method could be very helpful for making decision about the treatment of pregnant women who are at risk of lower BMD due to concomitant diseases and/or treatment associated with osteoporosis.References:[1]Casciaro S, Conversano F, Pisani P, Muratore M. New perspectives in echographic diagnosis of osteoporosis on hip and spine. Clin Cases Miner Bone Metab. 2015; 12(2):142-150.[2]Nikolov M, Nikolov N. AB0908 Assessment of the impact of the lean mass with body composition by dual-energy x-ray absorptiometry on the bone mineral density. Annals of the Rheumatic Diseases 2020; 79:1756.[3]Chakova M., Chernev D., Kashukeeva P., Krustev P., Abedinov F. Lumbar Sympathectomy - Literature Review. International Journal of Science and Research (IJSR) Volume 7 Issue 8, August 2018 ISSN (Online): 2319-7064.[4]Degennaro, V. A.; Cagninelli, G.; Lombardi, F. A. “VP34.12: First assessment of maternal status during pregnancy by means of radiofrequency echographic multi-spectrometry technology”. Ultrasound in Obstetrics & Gynecology. 2020, 56 (S1): 199.Disclosure of Interests:None declared.


2002 ◽  
Vol 96 (3) ◽  
pp. 309-312 ◽  
Author(s):  
John S. Sarzier ◽  
Avery J. Evans ◽  
David W. Cahill

Object. The authors conducted a biomechanical study to evaluate pedicle screw pullout strength in osteoporotic cadaveric spines. Nonaugmented hemivertebrae were compared with pressurized polymethylmethacrylate (PMMA)—augmented hemivertebrae. Methods. Six formalin-fixed cadaveric thoracolumbar spines at least two standard deviations below the mean bone mineral density (BMD) for age were obtained. Radiographic and BMD studies were correlated to grades I, II, and III osteoporosis according to the Jekei scale. Each of the 21 vertebrae underwent fluoroscopic placement of 6-mm transpedicular screws with each hemivertebra serving as the control for the contralateral PMMA-augmented hemivertebra. Pedicle screws were then evaluated for biomechanical axial pullout resistance. Augmented hemivertebrae axial pullout forces were increased (p = 0.0005). The mean increase in pullout force was 181% for Grade I, 206% for Grade II, and 213% for Grade III osteoporotic spines. Augmented Grade I osteoporotic spines demonstrated axial pullout forces near those levels reported in the literature for nonosteoporotic specimens. Augmented Grade II osteoporotic specimens demonstrated increases to levels found in nonaugmented vertebrae with low-normal BMD. Augmented Grade III osteoporotic specimens had increases to levels equal to those found in nonaugmented Grade I vertebrae. Conclusions. Augmentation of osteoporotic vertebrae in PMMA-assisted vertebroplasty can significantly increase pedicle screw pullout forces to levels exceeding the strength of cortical bone. The maximum attainable force appears to be twice the pullout force of the nonaugmented pedicle screw for each osteoporotic grade.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1188.1-1188
Author(s):  
C. Daldoul ◽  
N. El Amri ◽  
K. Baccouche ◽  
H. Zeglaoui ◽  
E. Bouajina

Background:Inflammatory bowel disease (IBD), including ulcerative colitis (UC) and Crohn’s disease (CD), is considered as a risk factor of low bone mineral density (BMD). In fact, the prevalence of osteoporosis ranges from 17% to 41% in IBD patients. The possible contributing factors may include malabsorption, glucocorticoid treatment and coexisting comorbiditiesObjectives:The purpose of our work was to determine the frequency and the determinants of osteoporosis in patients with IBD and to assess whether there is a difference in BMD status between UC and CD.Methods:This is a retrospective study, over a period of 5 years (from January 2014 to December 2018) and including patients followed for IBD who had a measurement of BMD by DEXA. Clinical, anthropometric and densitometric data (BMD at the femoral and vertebral site) were recorded. The WHO criteria for the definition of osteoporosis and osteopenia were applied.Results:One hundred and five patients were collected; among them 45 were men and 60 were women. The average age was 45.89 years old. The average body mass index (BMI) was 25.81 kg/m2 [16.44-44.15]. CD and UC were diagnosed in respectively 57.1% and 42.9%. A personal history of fragility fracture was noted in 4.8%. Hypothyroidism was associated in one case. Early menopause was recorded in 7.6%. 46.8% patients were treated with corticosteroids. The mean BMD at the vertebral site was 1.023 g/cm3 [0.569-1.489 g/cm3]. Mean BMD at the femoral site was 0.920g/cm3 [0.553-1.286g / cm3]. The mean T-score at the femoral site and the vertebral site were -1.04 SD and -1.27 SD, respectively. Osteoporosis was found in 25.7% and osteopenia in 37.1%. Osteoporosis among CD and UC patients was found in respectively 63% and 37%. The age of the osteoporotic patients was significantly higher compared to those who were not osteoporotic (52.23 vs 43.67 years, p = 0.01). We found a significantly higher percentage of osteoporosis among men compared to women (35.6% vs 18.3%, p=0.046). The BMI was significantly lower in the osteoporotic patients (23.87 vs 26.48 kg/m2, p=0.035) and we found a significant correlation between BMI and BMD at the femoral site (p=0.01). No increase in the frequency of osteoporosis was noted in patients treated with corticosteroids (27.9% vs 21.6%, p=0.479). Comparing the UC and CD patients, no difference was found in baseline characteristics, use of steroids or history of fracture. No statistically significant difference was found between UC and CD patients for osteoporosis(p=0.478), BMD at the femoral site (p=0.529) and at the vertebral site (p=0.568).Conclusion:Osteoporosis was found in 25.7% of IBD patients without any difference between CD and UC. This decline does not seem to be related to the treatment with corticosteroids but rather to the disease itself. Hence the interest of an early screening of this silent disease.Disclosure of Interests:None declared


2012 ◽  
Vol 27 (6) ◽  
pp. 686 ◽  
Author(s):  
Hyun Jung Hwang ◽  
Si Young Park ◽  
Soon Hyuck Lee ◽  
Seung Bum Han ◽  
Kyung Han Ro

Sign in / Sign up

Export Citation Format

Share Document