scholarly journals Identification of relevant acoustic transfer paths for WT drivetrains with an operational transfer path analysis

Author(s):  
W. Schünemann ◽  
R. Schelenz ◽  
G. Jacobs ◽  
W. Vocaet

AbstractThe aim of a transfer path analysis (TPA) is to view the transmission of vibrations in a mechanical system from the point of excitation over interface points to a reference point. For that matter, the Frequency Response Functions (FRF) of a system or the Transmissibility Matrix is determined and examined in conjunction with the interface forces at the transfer path. This paper will cover the application of an operational TPA for a wind turbine model. In doing so the path contribution of relevant transfer paths are made visible and can be optimized individually.

2019 ◽  
Vol 2019 ◽  
pp. 1-16
Author(s):  
Rong He ◽  
Hong Zhou

The time-domain substructure inverse matrix method has become a popular method to detect and diagnose problems regarding vehicle noise, vibration, and harshness, especially for those impulse excitations caused by roads. However, owning to its reliance on frequency response functions (FRFs), the approach is effective only for time-invariable linear or weak nonlinear systems. This limitation prevents this method from being applied to a typical vehicle suspension substructure, which shows different nonlinear characteristics under different wheel transient loads. In this study, operational excitation was considered as a key factor and applied to calculate dynamic time-varying FRFs to perform accurate time-domain transient vibration transfer path analysis (TPA). The core idea of this novel method is to divide whole coupled substructural relationships into two parts: one involved time-invariable components; normal FRFs could be obtained through tests directly. The other involved numerical computations of the time-domain operational loads matrix and FRFs matrix in static conditions. This method focused on determining dynamic FRFs affected by operational loads, especially the severe transient ones; these loads are difficult to be considered in other classical TPA approaches, such as operational path analysis with exogenous inputs (OPAX) and operational transfer path analysis (OTPA). Experimental results showed that this new approach could overcome the limitations of the traditional time-domain substructure TPA in terms of its strict requirements within time-invariable systems. This is because in the new method, time-varying FRFs were calculated and used, which could make the FRFs at the system level directly adapt to time-varying systems from time to time. In summary, the modified method extends TPA objects studied in time-invariable systems to time-varying systems and, thus, makes a methodology and application innovation compared to traditional the time-domain substructure TPA.


2017 ◽  
Vol 2017 ◽  
pp. 1-15 ◽  
Author(s):  
Changheon Song ◽  
Dae Ji Kim ◽  
Jintai Chung ◽  
Kang Won Lee ◽  
Sang Seuk Kweon ◽  
...  

The aim of this study is to estimate the impact loads delivered to the housing of a hydraulic breaker quantitatively. Striking forces caused vibrations in the equipment housing, which were experimentally measured, and frequency response functions were also found through modal impact experiments. Transfer path analysis (TPA) method of the data quantified the impact loads delivered to the housing. TPA method can analyze the relationship between the vibration energy and the transfer path of an excitation source and so explore the way in which vibrations on each path contribute to the entire vibration profile. The impact loads of each part derived by TPA method were compared with the impact loads in the chisel derived from strain gauge measurements of the striking energy. This comparison validated the TPA approach. This study describes the basic concepts and components of TPA method and also reviews its applicability to mechanical equipment that experiences impact vibrations and impact loads.


Vibration ◽  
2021 ◽  
Vol 4 (2) ◽  
pp. 406-413
Author(s):  
Michael Schnell ◽  
Nicole Wörz ◽  
Frank Gauterin

In a previous paper, it was determined that coolant fluids can have a significant influence on the acoustic emission of an electric motor. There is no appliance that can investigate and compare the transfer path analysis of isolated fluids. For this case, a new fixture is introduced and its suitability is evaluated. Furthermore, the appliance is used to measure and compare different media and their frequency response functions. The results indicate that the fixture and its repeatability are suitable to measure and compare fluids and media. A comparison of different media shows how the air medium has the lowest amplitudes for the transfer path analysis, in relation to incompressible fluids. Furthermore, differences in the transfer path analysis between both considered gearbox oils are marginal. While the utilization of air as a coolant medium is not always possible, due to thermal issues, the presented fixture can help find an acoustically suitable coolant medium for future applications in electric motors. Additionally, it is possible to investigate the influence of temperature and pressure conditions on the transfer path analysis of fluids.


Author(s):  
Marcus Neubauer ◽  
Andreas Renner ◽  
Jo˜rg Wallaschek

Piezoelectric self-sensing allows the measurement of frequency response functions of dynamical systems with one single piezoelectric element. This piezoceramics is used as actuator and sensor simultaneously. In this study, the frequency response functions are obtained by measuring the current flowing through the piezoelectric element, while it is driven by a harmonic voltage signal with constant amplitude. The current flow is composed of the part which is required to drive the piezoelectric element as an actuator and a second part which is the sensor signal that is proportional to the vibration amplitude of the attached mechanical system. Especially for low electromechanical coupling the first part is dominant and the influence of the mechanical system is only marginal. With an idealized mathematical model of the piezoelectric element, the admittance can be calculated and the actuator current can be eliminated from the measured signal. This software-based solution does not require any additional electrical circuits or precise tuning during the measurements. The influence of errors of the parameters for the piezoelectric model on the recalculated signals are shown, which helps to improve the estimations. Alternatively, they can be obtained by additional measurements. The proposed technique is demonstrated on a clamped beam with attached piezoelectric element.


Sign in / Sign up

Export Citation Format

Share Document