scholarly journals Network architecture strongly influences the fluid flow pattern through the lacunocanalicular network in human osteons

2019 ◽  
Vol 19 (3) ◽  
pp. 823-840 ◽  
Author(s):  
Alexander F. van Tol ◽  
A. Roschger ◽  
F. Repp ◽  
J. Chen ◽  
P. Roschger ◽  
...  

AbstractA popular hypothesis explains the mechanosensitivity of bone due to osteocytes sensing the load-induced flow of interstitial fluid squeezed through the lacunocanalicular network (LCN). However, the way in which the intricate structure of the LCN influences fluid flow through the network is largely unexplored. We therefore aimed to quantify fluid flow through real LCNs from human osteons using a combination of experimental and computational techniques. Bone samples were stained with rhodamine to image the LCN with 3D confocal microscopy. Image analysis was then performed to convert image stacks into mathematical network structures, in order to estimate the intrinsic permeability of the osteons as well as the load-induced fluid flow using hydraulic circuit theory. Fluid flow was studied in both ordinary osteons with a rather homogeneous LCN as well as a frequent subtype of osteons—so-called osteon-in-osteons—which are characterized by a ring-like zone of low network connectivity between the inner and the outer parts of these osteons. We analyzed 8 ordinary osteons and 9 osteon-in-osteons from the femur midshaft of a 57-year-old woman without any known disease. While the intrinsic permeability was 2.7 times smaller in osteon-in-osteons compared to ordinary osteons, the load-induced fluid velocity was 2.3 times higher. This increased fluid velocity in osteon-in-osteons can be explained by the longer path length, needed to cross the osteon from the cement line to the Haversian canal, including more fluid-filled lacunae and canaliculi. This explanation was corroborated by the observation that a purely structural parameter—the mean path length to the Haversian canal—is an excellent predictor for the average fluid flow velocity. We conclude that osteon-in-osteons may be particularly significant contributors to the mechanosensitivity of cortical bone, due to the higher fluid flow in this type of osteons.

2022 ◽  
Vol 642 ◽  
pp. 119920
Author(s):  
Shuang Song ◽  
Liangwan Rong ◽  
Kejun Dong ◽  
Xuefei Liu ◽  
Pierre Le-Clech ◽  
...  

Author(s):  
Wan Faezah Wan Azmi ◽  
Ahmad Qushairi Mohamad ◽  
Lim Yeou Jiann ◽  
Sharidan Shafie

Casson fluid is a non-Newtonian fluid with its unique fluid behaviour because it behaves like an elastic solid or liquid at a certain condition. Recently, there are several studies on unsteady Casson fluid flow through a cylindrical tube have been done by some researchers because it is related with the real-life applications such as blood flow in vessel tube, chemical and oil flow in pipelines and others. Therefore, the main purpose of the present study is to obtain analytical solutions for unsteady flow of Casson fluid pass through a cylinder with slip velocity effect at the boundary condition. Dimensional governing equations are converted into dimensionless forms by using the appropriate dimensionless variables. Dimensionless parameters are obtained through dimensionless process such as Casson fluid parameters. Then, the dimensionless equations of velocity with the associated initial and boundary conditions are solved by using Laplace transform with respect to time variable and finite Hankel transform of zero order with respect to the radial coordinate. Analytical solutions of velocity profile are obtained. The obtained analytical result for velocity is plotted graphically by using Maple software. Based on the obtained result, it can be observed that increasing in Casson parameter, time and slip velocity will lead to increment in fluid velocity. Lastly, Newtonian fluid velocity is uniform from the boundary to the center of cylinder while Casson fluid velocity is decreased when approaching to the center of cylinder. The present result is validated when the obtained analytical solution of velocity is compared with published result and found in a good agreement.


2016 ◽  
Vol 70 (4) ◽  
pp. 367-381 ◽  
Author(s):  
Radmila Secerov-Sokolovic ◽  
Dunja Sokolovic ◽  
Dragan Govedarica

This paper presents a literature review on the current understanding of liquid-liquid separation that is immensely widespread in practice, highlighting the steady-state bed coalescer being a good solution in various engineering application. Generally, the fibre bed coalescence has proven to be very effective separation method in the industry. Due to the complexity of bed coalescence phenomenon coalescer design and sizing procedure relies on experimental test. This review provides a research overview of the key phenomena essential for the efficient bed coalescence, such as mechanisms of droplet coalescence and emulsion flow through the fibre bed. In addition to this provides an overview of the current knowledge about coalescer?s design properties and variables such as: fluid velocity, fluid flow orientation/flow mode, fibre bed geometry, and bed length.


2016 ◽  
Vol 19 (5) ◽  
pp. 391-404 ◽  
Author(s):  
B. M. Shankar ◽  
I. S. Shivakumara ◽  
Chiu-On Ng

2014 ◽  
Vol 17 (11) ◽  
pp. 1019-1029 ◽  
Author(s):  
Mohammad Zafari ◽  
Masoud Panjepour ◽  
Mohsen Davazdah Emami ◽  
Mahmood Meratian

Sign in / Sign up

Export Citation Format

Share Document