A Simple Limit Equilibrium Approach for Calculation of Ultimate Bearing Capacity of Shallow Foundations on Two-Layered Granular Soils

2008 ◽  
Vol 26 (5) ◽  
pp. 535-542 ◽  
Author(s):  
Mahmoud Ghazavi ◽  
Amir Hossein Eghbali
2014 ◽  
Vol 19 (Supplement_1) ◽  
pp. S78-S90 ◽  
Author(s):  
Ehsan Sadrossadat ◽  
Fazlollah Soltani ◽  
Seyyed Mohammad Mousavi ◽  
Seyed Morteza Marandi ◽  
Amir H. Alavi

A major concern in design of structures is to provide precise estimations of ultimate bearing capacity of soil beneath their foundations. Direct determination of the bearing capacity of foundations requires performing expensive and time consuming laboratory tests. To cope with this issue, several numerical models have been presented by researchers. This paper presents the development of a new design equation for the prediction of the ultimate bearing capacity of shallow foundations on granular soils using linear genetic programming (LGP) methodology. The ultimate bearing capacity is formulated in terms of width of footing, footing geometry, depth of footing, unit weight of sand, and angle of shearing resistance. The LGP-based design equation is established using the results of several load tests on real sized foundations presented in the literature. Validity of the model is verified using a part of laboratory data that are not involved in the calibration process. The statistical measures of coefficient of determination, root mean squared error and mean absolute error are used to evaluate the performance of the model. Sensitivity and parametric analyses are conducted and discussed. The proposed model accurately characterizes the ultimate bearing capacity resulting in a very good prediction performance. The LGP model reaches a better prediction performance than the well-known prediction equations for the bearing capacity of shallow foundations.


2011 ◽  
Vol 52-54 ◽  
pp. 1400-1405 ◽  
Author(s):  
Anuchit Uchaipichat ◽  
Ekachai Man-Koksung

Typically a shallow foundation is chosen to support several types of common structure. Several equations for the ultimate bearing capacity of shallow foundation have been proposed with assumption of fully saturated or completely dry conditions. In fact, almost 40 percent of natural soils on the earth surface are in an unsaturated state. Therefore, the ultimate bearing capacity of shallow strip foundation on unsaturated granular soils is developed in this paper using limit equilibrium concept. The simulations from the developed equation for a laboratory-compacted-sand are performed. The results are carefully presented and discussed.


2011 ◽  
Vol 261-263 ◽  
pp. 989-993 ◽  
Author(s):  
Anuchit Uchaipichat ◽  
Ekachai Man Koksung

An experimental program of laboratory bearing tests was performed to characterize the bearing capacity of foundation on unsaturated granular soils. All tests were performed by pushing a circular rod on the surface of compacted sand specimens with different values of matric suction until failure. The test results show an increase in ultimate bearing capacity with increasing matric suction at low suction value but a decrease in that at high level of suction. The comparisons between the test results and simulations using the expressions proposed in this paper are presented and discussed. Good agreements are achieved for all testing values of suction.


Geosciences ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 392
Author(s):  
Maurizio Ziccarelli ◽  
Marco Rosone

The presence of minor details of the ground, including soil or rock masses, occurs more frequently than what is normally believed. Thin weak layers, shear bands, and slickensided surfaces can substantially affect the behaviour of foundations, as well as that of other geostructures. In fact, they can affect the failure mechanisms, the ultimate bearing capacity of footings, and the safety factor of the geotechnical system. In this research, numerically conducted through Finite Element Code Plaxis 2D, the influence of a horizontal thin weak layer on the mechanical behaviour of shallow footings was evaluated. The obtained results prove that the weak layer strongly influences both the failure mechanism and the ultimate bearing capacity if its depth is lower than two to four times the footing width. In fact, under these circumstances, the failure mechanisms are always mixtilinear in shape because the shear strains largely develop on the weak layer. However, the reduction in the ultimate bearing capacity is a function of the difference between the shear strength of the foundation soil and the layer. The presence of a thin weak layer decreases the ultimate bearing capacity up to 90%. In conclusion, this research suggests that particular attention must be paid during detailed ground investigations to find thin weak layers. Based on the obtained results, it is convenient to increase the soil volume investigation to a depth equal to four times the width of the foundation.


2020 ◽  
Vol 2020 ◽  
pp. 1-14
Author(s):  
Qing Yan ◽  
Junhai Zhao ◽  
Changguang Zhang ◽  
Jintai Wang

The reasonable determination of ultimate bearing capacity is crucial to an optimal design of shallow foundations. Soils surrounding shallow foundations are commonly located above the water table and are thus in an unsaturated state. The intermediate principal stress has an improving effect on the unsaturated soil strength. In this study, the ultimate bearing capacity formulation of strip foundations in unsaturated soils is presented by using Terzaghi’s theory. The unified shear strength equation of unsaturated soils under a plane strain condition is utilized to capture the intermediate principal stress effect. Furthermore, two profiles of matric suction are considered and a hyperbolic function of the friction angle related to matric suction (φb) is adopted to describe strength nonlinearity. The validity of this study is demonstrated by comparing it with model tests and a theoretical solution reported in the literature. Finally, parameter studies are conducted to investigate the effects of intermediate principal stress, matric suction, and base roughness on the ultimate bearing capacity of strip foundations. Besides, the effect of strength nonlinearity is discussed with two methods representing the angle φb.


1993 ◽  
Vol 30 (3) ◽  
pp. 545-549 ◽  
Author(s):  
M.T. Omar ◽  
B.M. Das ◽  
V.K. Puri ◽  
S.C. Yen

Laboratory model test results for the ultimate bearing capacity of strip and square foundations supported by sand reinforced with geogrid layers have been presented. Based on the model test results, the critical depth of reinforcement and the dimensions of the geogrid layers for mobilizing the maximum bearing-capacity ratio have been determined and compared. Key words : bearing capacity, geogrid, model test, reinforced sand, shallow foundation.


2016 ◽  
Vol 53 (7) ◽  
pp. 1047-1058 ◽  
Author(s):  
M. Mosallanezhad ◽  
N. Hataf ◽  
S.H. Sadat Taghavi

Soil reinforcement by means of geogrid is an effective method of increasing the ultimate bearing capacity (UBC) of granular soils. In this study a new system, created by adding cubic anchors to ordinary geogrids, is introduced to increase the UBC of granular soils. This system is called “grid-anchor” (G-A). To analyse the performance of the G-A system in increasing the UBC of granular soils, 45 experimental tests and 9 field tests were performed, the results of which show that the G-A system is 1.8 times more capable than ordinary geogrids in increasing the UBC in square foundations. Furthermore, the failure of soil reinforced by the ordinary geogrid takes place at a settlement of 9% of the foundation width, while the same value for the G-A system is almost 13%.


Sign in / Sign up

Export Citation Format

Share Document