Divergent responses of diverse microalgae commonly found in drinking water source water to UV-C treatment

Author(s):  
Jordan Roszell ◽  
Po-Shun Chan ◽  
Brian Petri ◽  
Ted Mao ◽  
Kathleen Nolan ◽  
...  
2021 ◽  
Author(s):  
◽  
Amie Siedlecki ◽  

For many communities, drinking water comes from surface water sources, or source water, such as rivers and creeks. Within the city of Grants Pass, Oregon, this is the case. The Rogue River, which spans 215 miles, beginning near Crater Lake and emptying into the ocean at Gold Beach, is Grants Pass’ drinking water source. While the capacity of the Rogue River, in relation to drinking water, is rarely an issue for the City of Grants Pass’ Public Works Department, the potential contaminant sources (PCS) from the urban, commercial, and industrial geographical areas of Grants Pass is a concern. In order to deploy treatment processes that are capable of targeting these PCS, it is important to have an idea of where and how these PCS are reaching the storm drains, creeks, and eventually the Rogue River. The purpose of this study was to identify area-specific risk components and how those components spatially aligned with PCS and their locations. Geographic Information System (GIS) analysis and a risk matrix were used to rank the PCS according to risk in relation to Grants Pass’ source water intake. PCS ranked as high priority, or exuding the highest risk to drinking water quality, were followed up with onthe- ground surveys. After surveying the high priority PCS, best management practices (BMP) recommendations were made to the City of Grants Pass to better protect the drinking water quality. Branching off of this initial project work came similar studies in many other Rogue Basin communities. With this continued work, improvements were made to streamline the processes, such as recording survey observations. Overall, this project work has led to many discoveries regarding threats to drinking water quality and how to best respond to certain types of threats.


2020 ◽  
Author(s):  
John Weatherill ◽  
Elena Fernandez-Pascual ◽  
Jean O'Dwyer ◽  
Elizabeth Gilchrist ◽  
Simon Harrison ◽  
...  

<p>Ireland has a far greater number of regulatory exceedances for trihalomethanes (THMs) in public water supplies than the next highest European Union member state. In Ireland, 82% of public water supplies originate from surface water catchments which require disinfection to inactivate pathogens and prevent the spread of waterborne diseases. Since the 1970s, it has been known that the use of chlorine for disinfection leads to the formation of potentially harmful disinfection byproducts (DBPs) of which some are suspected carcinogens. THMs are one prominent class of at least 700 potentially harmful disinfection byproducts (DBPs) produced after chlorination of dissolved organic matter (DOM) present in source water which is not removed prior to disinfection.</p><p>We introduce a new research project, funded by the Irish Environmental Protection Agency entitled PRODOM: PRoactive Optical monitoring of catchment Dissolved Organic Matter for drinking water source protection. The overall aim of the research is to develop an integrated catchment-level understanding of the spatiotemporal dynamics of DOM precursors and associated DBP formation risk. The project will explore the relationship between optically-active DOM precursors and laboratory formation potentials for key DBPs including emerging classes of potentially more harmful nitrogenous DBPs. Through high-resolution spatial sampling we will develop geospatial DBP formation risk maps and identify risk-driving point and diffuse precursor sources. We will evaluate the potential of state-of-the-art UV fluorescence sensor technology to act as an early warning tool for proactive management of source water at sub-catchment scale. Using high-frequency time series monitoring of fluorescent precursors, we will identify high-risk periods in the catchment hydrograph and evaluate critical precursor sources and pathways to inform a series of catchment management measures designed to reduce DBP formation risk. </p>


2021 ◽  
Author(s):  
Qingyuan Guo ◽  
Zhaoxia Li ◽  
Tianming Chen ◽  
Bairen Yang ◽  
Cheng Ding

Abstract Sudden odor incidents occurring in the source water have been a severe problem for water suppliers. In order to apply emergency control measures effectively, it is necessary to identify the target compounds responsible for odor incidents rapidly. The present work identified the odorants and explored emergency disposal mechanisms for sudden and severe odors in the QT River's drinking water source (HZ city, China). Medicinal, chemical, septic, and musty odors with strong intensities were detected in the source water. The effect of conventional treatments of drinking water treatment plant (DWTP) on odors' removal was limited, which was evident by the presence of medicinal, chemical, and musty odors with moderate intensities in the effluent of DWTP. Total seventeen odorants were identified successfully in the source water of QT River and the effluent of DWTP. The measured OAVs and reconstituting the identified odorants explained 87%, 87%, 89%, and 94% of medicinal, chemical, septic, and musty odors, respectively, in the source water of the QT River and 90%, 87%, and 88% of medicinal, chemical, and musty odors in the effluent. Styrene, phenol, 2-chlorophenol, 2-tert-butylphenol, and 2-methylphenol were associated with the medicinal odor, while propyl sulfide, diethyl disulfide, propyl disulfide, and indole were related to the septic odor. Geosmin and 2-methylisoborneol (2-MIB) were responsible for the musty odor, and cyclohexanone, 1,4-dichlorobenzene, and nitrobenzene were involved with the chemical odor. Based on the characteristics of identified odorants, powdered activated carbon (PAC) was applied to control the odors in the QT River. The results indicated that the medicinal, chemical, septic, and musty odors could be removed entirely after adding 15 mg/L PAC, which effectively controlled emergency odor problems. Overall, the study would offer a scientific basis and operational reference for emergency odor management and control in DWTP with similar complicated odor incidents.


2021 ◽  
Vol 3 (3) ◽  
Author(s):  
Elizabeth Crafton ◽  
Jessica Glowczewski ◽  
Teresa Cutright ◽  
Don Ott

AbstractThree copper-based algaecide products were investigated for use in a drinking water source to address cyanobacteria growth. Bench-scale experiments were used to determine the optimal dose of each product given Lake Rockwell’s indigenous population and reservoir-specific characteristics. The optimal dose of Cutrine Ultra was determined to be a quarter dose (corresponding to 0.125 mg/L Cu) as it decreased 55% of the cyanobacteria population with limited release of microcystin and minimal rebound in the cyanobacteria population. The optimal dose for EarthTec was determined to be a half dose (i.e., 0.5 mg/L). The full dose was optimal for SeClear (1 mg/L Cu). The optimal doses had extracellular microcystin levels of 0.99 ± 0.09 µg/L (quarter dose Cutrine Ultra), 3.69 ± 0.43 µg/L (half dose EarthTec) and 0.92 ± 0.26 µg/L (full dose SeClear) by day 2. EarthTec and Cutrine Ultra facilitated a similar overall response, and the cyanobacteria population was predominately suppressed in the initial 2 days following treatment and then increased between 7 and 14 days after treatment (i.e., rebound). Both the suppression within the first 2 days and the rebound between 7 and 14 days after treatment were a function of dose (e.g., lower dose, larger increase in rebound). Although SeClear suppressed the cyanobacteria population during the initial 2 days after treatment (42,000 ± 3240 cells/mL at the baseline to 4822 ± 841), the cyanobacteria population rebounded significantly (p < 0.05) between 2 and 7 days after treatment.


Author(s):  
Chloé Meyer

Population using an improved drinking water source (piped water into dwellings, yards or plots; public taps or standpipes; boreholes or tubewells; protected dug wells; or protected springs and rainwater) that is located on premises and available when needed and which is free of faecal and priority chemical contamination. Basin Pollution Quality Waste


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Abdul-Aziz Seidu

Abstract Background Safe disposal of children’s faeces has always been one of the main challenges to good hygiene in Ghana. Although it has been proven that children’s faeces are more likely to spread diseases than adults’ faeces, people usually mistake them for harmlessness. This study, therefore, sought to determine the prevalence and factors associated with safe disposal of children’s faeces in Ghana. Methods Data from the 2014 Ghana Demographic and Health Survey was used for the analysis. A sample size of 2228 mother-child pairs were used for the study. The outcome variable was disposal of children stools. Both bivariate and multivariable logistic regression analyses were performed to identify the factors with safe child stool disposal. Results The prevalence of safe child stool disposal in Ghana was 24.5%. Women in the middle [Adjusted odds ratio (AOR) = 4.62; Confidence Interval (CI) = 3.00–7.10], Coastal Zone [AOR = 4.52; CI = 2.82–7.22], mothers whose children were aged 12–17 [AOR = 1.56; CI = 1.15–2.13] and 18–23 months [AOR = 1.75; CI = 1.29–2.39], and mothers whose household had improved type of toilet facility [AOR = 2.04; CI = 1.53–2.73] had higher odds of practicing safe children’s faeces disposal. However, women from households with access to improved source of drinking water [AOR = 0.62; CI = 0.45–2.7] had lower odds of practicing safe children’s faeces disposal. Conclusion Approximately only about 25 out of 100 women practice safe disposal of their children’s faeces in Ghana. The age of the child, ecological zone, the type of toilet facilities, and the type of drinking water source are associated with the disposal of child faeces. These findings have proven that only improved sanitation (i.e. drinking water and toilet facilities) are not enough for women to safely dispose of their children’s faeces. Therefore, in addition to provision of toilet facilities especially in the northern zone of Ghana, there is also the need to motivate and educate mothers on safe disposal of children’s stools especially those with children below 12 months. More so, mothers without access to improved toilet facility should also be educated on the appropriate ways to bury their children’s stools safely.


Sign in / Sign up

Export Citation Format

Share Document