Flat-plate roof collapse of shallow caverns and protective measures: a case study of Longyou ancient siltstone caverns

2014 ◽  
Vol 76 (1) ◽  
pp. 191-213 ◽  
Author(s):  
Zhongjian Zhang ◽  
Lihui Li ◽  
Wenjie Xu ◽  
Yan Fu ◽  
Jun Feng
2016 ◽  
Vol 371 (1689) ◽  
pp. 20150213 ◽  
Author(s):  
Fabrice Pernet ◽  
Coralie Lupo ◽  
Cédric Bacher ◽  
Richard J. Whittington

Emerging diseases pose a recurrent threat to bivalve aquaculture. Recently, massive mortality events in the Pacific oyster Crassostrea gigas associated with the detection of a microvariant of the ostreid herpesvirus 1 (OsHV-1µVar) have been reported in Europe, Australia and New Zealand. Although the spread of disease is often viewed as a governance failure, we suggest that the development of protective measures for bivalve farming is presently held back by the lack of key scientific knowledge. In this paper, we explore the case for an integrated approach to study the management of bivalve disease, using OsHV-1 as a case study. Reconsidering the key issues by incorporating multidisciplinary science could provide a holistic understanding of OsHV-1 and increase the benefit of research to policymakers.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1829 ◽  
Author(s):  
Piotr Olczak ◽  
Dominika Matuszewska ◽  
Jadwiga Zabagło

In Poland, various solar collector systems are used; among them, the most popular are flat plate collectors (FPCs) and evacuated tube collectors (ETCs). The work presents two installations located at a distance of 80 km apart, working in similar external conditions. One of them contains 120 flat plate collectors and works for the preparation of hot water in a swimming pool building; the second one consists of 32 evacuated tube collectors with a heat pipe and supports the preparation of domestic hot water for a multi-family house. During the comparison of the two quite large solar installations, it was confirmed that the use of evacuated tube solar collectors shows a much better solar energy productivity than flat plate collectors for the absorber area. Higher heat solar gains (by 7.9%) were also observed in the case of the gross collector area. The advantages of evacuated tube collectors are observed mainly during colder periods, which allows for a steadier thermal energy production.


Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3883
Author(s):  
Jorge E. De León-Ruiz ◽  
Ignacio Carvajal-Mariscal ◽  
Antonin Ponsich

The present work conducts an evaluation of the feasibility and the overall performance and consequent optimization of a direct expansion solar assisted heat pump (DXSAHP) employed for domestic water heating. For the study conducted R134a, R404A, R407C and R410A working fluids were evaluated as well as the use of four, six and eight flat-plate solar collectors and a worktime ranging from 1 to 6 h. The case study is based in Mexico City with a 300 L container and a hot water outlet temperature of 51 °C. The paper introduces a new evaluation criterion based on the thermal capacity and all the evaluations conducted throughout this research revolve around this performance metric. The results show that, the system would require at least 4 h of operation to achieve the outlet temperature. Additionally, it was found that the R410A refrigerant has the best heat transfer properties; with an average condensation heat rate of 6.31 kW, followed by the R407C with 5.72 kW, the R404A with 5.42 kW and the R134a with 5.18 kW. Diversely, the R134a refrigerant requires 0.402 kW of compression work, 62% less than the R410A, which requires 1.06 kW. Consequently, R134a delivers the highest COP, which ranges from 7 to 14, followed by the R407C and R404A refrigerants, which present a similar behaviour between them, with COP ranging from 5 to 9 and 4 to 8, respectively, and finally the R410A, achieving the lowest COP, ranging from 3.5 to 6.5. Moreover, it was found that the R134a presents a higher dispersion regarding the energy exchange rate, which reveals that it is the fluid most susceptible to external factors, such as the weather. Contrarily, the remaining refrigerants present a more consistent performance. Finally, the optimization revealed that the R407C refrigerant is the most suitable given that it requires 20% less compression work than the R404A. This provides the heat pump system with a steadier behaviour, a COP ranging from 7 to 8, 30% higher than R410A, a worktime decrease of 1.5 h and heat transfer area of 5.5 flat-plate solar collectors, equivalent to a 31% reduction, both compared to R134a.


1999 ◽  
Vol 8 (1) ◽  
pp. 77-107 ◽  
Author(s):  
JAR Nafziger ◽  
RJ Dobkins

The global effort to protect indigenous heritage relies on national legislation. The Native American Graves Protection and Repatriation Act (NAGPRA) of the United States provides one model for accomplishing a broad agenda of protective measures. NAGPRA confirms indigenous ownership of cultural items excavated or discovered on federal and tribal lands, criminalizes trafficking in indigenous human remains and cultural items, and establishes a process of repatriation of material to native groups. In implementing the law, questions related to cultural affiliation, culturally unidentifiable material, the status of native groups not recognized by the federal government, and the scope of a group's cultural patrimony have been particularly troublesome. A case study of the repatriation process highlights issues in implementing NAGPRA and benefits in fostering consultation and collaboration among native groups, museums, and federal agencies. Finally, the article considers the controversies that have come before a statutory review committee and the federal courts during NAGPRA's first decade. This experience demonstrates the limitations of formal dispute resolution as a means of developing and implementing the law.


2006 ◽  
Vol 47 (5) ◽  
pp. 624-637 ◽  
Author(s):  
Hamdy K. Elminir ◽  
Ahmed E. Ghitas ◽  
F. El-Hussainy ◽  
R. Hamid ◽  
M.M. Beheary ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document