scholarly journals Validating CFD Predictions of Pharmaceutical Aerosol Deposition with In Vivo Data

2015 ◽  
Vol 32 (10) ◽  
pp. 3170-3187 ◽  
Author(s):  
Geng Tian ◽  
Michael Hindle ◽  
Sau Lee ◽  
P. Worth Longest
2021 ◽  
Vol 11 (5) ◽  
pp. 431
Author(s):  
Sabine Hofer ◽  
Norbert Hofstätter ◽  
Albert Duschl ◽  
Martin Himly

COVID-19, predominantly a mild disease, is associated with more severe clinical manifestation upon pulmonary involvement. Virion-laden aerosols and droplets target different anatomical sites for deposition. Compared to droplets, aerosols more readily advance into the peripheral lung. We performed in silico modeling to confirm the secondary pulmonary lobules as the primary site of disease initiation. By taking different anatomical aerosol origins into consideration and reflecting aerosols from exhalation maneuvers breathing and vocalization, the physicochemical properties of generated respiratory aerosol particles were defined upon conversion to droplet nuclei by evaporation at ambient air. To provide detailed, spatially-resolved information on particle deposition in the thoracic region of the lung, a top-down refinement approach was employed. Our study presents evidence for hot spots of aerosol deposition in lung generations beyond the terminal bronchiole, with a maximum in the secondary pulmonary lobules and a high preference to the lower lobes of both lungs. In vivo, initial chest CT anomalies, the ground glass opacities, resulting from partial alveolar filling and interstitial thickening in the secondary pulmonary lobules, are likewise localized in these lung generations, with the highest frequency in both lower lobes and in the early stage of disease. Hence, our results suggest a disease initiation right there upon inhalation of virion-laden respiratory aerosols, linking the aerosol transmission route to pathogenesis associated with higher disease burden and identifying aerosol transmission as a new independent risk factor for developing a pulmonary phase with a severe outcome.


Atmosphere ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 137 ◽  
Author(s):  
Vu Khac Hoang Bui ◽  
Ju-Young Moon ◽  
Minhe Chae ◽  
Duckshin Park ◽  
Young-Chul Lee

The measurement of deposited aerosol particles in the respiratory tract via in vivo and in vitro approaches is difficult due to those approaches’ many limitations. In order to overcome these obstacles, different computational models have been developed to predict the deposition of aerosol particles inside the lung. Recently, some remarkable models have been developed based on conventional semi-empirical models, one-dimensional whole-lung models, three-dimensional computational fluid dynamics models, and artificial neural networks for the prediction of aerosol-particle deposition with a high accuracy relative to experimental data. However, these models still have some disadvantages that should be overcome shortly. In this paper, we take a closer look at the current research trends as well as the future directions of this research area.


1989 ◽  
Vol 67 (6) ◽  
pp. 2579-2585 ◽  
Author(s):  
C. S. Kim ◽  
M. A. Eldridge ◽  
L. Garcia ◽  
A. Wanner

Both the total and regional aerosol deposition were measured in six adult sheep before and after an induction of asymmetric airway obstructions, either by local instillation of carbachol solution (CS, 0.1%) distal to the right main bronchus or inhalation challenge of the right lung with carbachol aerosol (CA, 10 breaths). Total lung deposition was determined by monitoring inert monodisperse aerosols [1.0 micron mass median aerodynamic diam (MMAD)] breath-by-breath, at the mouth, by means of a laser aerosol photometer. Cumulative aerosol deposition over the first five breaths as a percent of the initial aerosol concentration (AD5) was used as a deposition index. Regional deposition pattern was determined by scintigraphic images of sulfur-colloid aerosol (1.5 microns MMAD) tagged with 99mTc. Radioactivity counts in the right (R) and left lung (L) were expressed as a percent of the whole lung count. Half-lung AD5 was then determined by multiplying AD5 by fractional radioaerosol depositions in R or L. Pulmonary airflow resistance (RL mean +/- SE), as determined by an esophageal balloon technique, increased by 111 +/- 28 and 250 +/- 96% after CA and CS, respectively (P less than 0.05). AD5 also increased in all the sheep tested by 29 +/- 3 and 52 +/- 8%, respectively, after CA and CS (P less than 0.05). Radioaerosol deposition pattern was even at base line (R/L = 51:49) but shifted toward the unchallenged L after CS (R/L = 40:60). Deposition pattern after CA was variable: a shift toward L in three, no change in one, and a shift toward the R lung in two sheep.(ABSTRACT TRUNCATED AT 250 WORDS)


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Yoann Montigaud ◽  
Quentin Georges ◽  
Jérémie Pourchez ◽  
Lara Leclerc ◽  
Clémence Goy ◽  
...  

AbstractIn intensive care units, nebulization is a usual route for drug administration to patients under mechanical ventilation (MV). The effectiveness of inhalation devices as well as depositions sites of aerosols for ventilated patients remain poorly documented. In vivo human inhalation studies are scarce due to ethical restrictions because imaging techniques require radioaerosols to assess regional aerosol deposition. Thus, we developed an ex vivo respiratory model under invasive MV for preclinical aerosol deposition studies. The model was composed of ex vivo porcine respiratory tracts. MV was achieved thanks to a tracheal intubation and a medical ventilator under controlled conditions. Respiratory features were studied using analogical sensors. Then regional homogeneity of gas-ventilation was assessed with 81mKrypton scintigraphies. Finally, a proof of concept study for aerosol deposition was performed. Obtained respiratory features as well as gamma-imaging techniques, which demonstrated a homogenous regional ventilation and about 18% ± 4% of the nebulized dose deposited the respiratory tract, were in good agreement with human data available in the literature. This original ex vivo respiratory model provides a feasible, reproducible and cost-effective preclinical tool to achieve aerosol deposition studies under MV.


1996 ◽  
Vol 27 (5) ◽  
pp. 785-801 ◽  
Author(s):  
Kuo-Hsi Cheng ◽  
Yung-Sung Cheng ◽  
Hsu-Chi Yeh ◽  
Raymond A. Guilmette ◽  
Steven Q. Simpson ◽  
...  

2016 ◽  
Vol 51 (3) ◽  
pp. 363-376 ◽  
Author(s):  
Michael Y. Yang ◽  
Conor Ruzycki ◽  
Jordan Verschuer ◽  
Andrew Katsifis ◽  
Stefan Eberl ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document