scholarly journals Evaluation of accuracy, exclusivity, limit-of-detection and ease-of-use of LumiraDx™: An antigen-detecting point-of-care device for SARS-CoV-2

Infection ◽  
2021 ◽  
Author(s):  
Lisa J. Krüger ◽  
Julian A. F. Klein ◽  
Frank Tobian ◽  
Mary Gaeddert ◽  
Federica Lainati ◽  
...  

Abstract Purpose Rapid antigen-detecting tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can transform pandemic control. Thus far, sensitivity (≤ 85%) of lateral-flow assays has limited scale-up. Conceivably, microfluidic immunofluorescence Ag-RDTs could increase sensitivity for SARS-CoV-2 detection. Methods This multi-centre diagnostic accuracy study investigated performance of the microfluidic immunofluorescence LumiraDx™ assay, enrolling symptomatic and asymptomatic participants with suspected SARS-CoV-2 infection. Participants collected a supervised nasal mid-turbinate (NMT) self-swab for Ag-RDT testing, in addition to a professionally collected nasopharyngeal (NP) swab for routine testing with reverse transcriptase polymerase chain reaction (RT-PCR). Results were compared to calculate sensitivity and specificity. Sub-analyses investigated the results by viral load, symptom presence and duration. An analytical study assessed exclusivity and limit-of-detection (LOD). In addition, we evaluated ease-of-use. Results The study was conducted between November 2nd 2020 and 4th of December 2020. 761 participants were enrolled, with 486 participants reporting symptoms on testing day. 120 out of 146 RT-PCR positive cases were detected positive by LumiraDx™, resulting in a sensitivity of 82.2% (95% CI 75.2–87.5%). Specificity was 99.3% (CI 98.3–99.7%). Sensitivity was increased in individuals with viral load ≥ 7 log10 SARS-CoV2 RNA copies/ml (93.8%; CI 86.2–97.3%). Testing against common respiratory commensals and pathogens showed no cross-reactivity and LOD was estimated to be 2–56 PFU/mL. The ease-of-use-assessment was favourable for lower throughput settings. Conclusion The LumiraDx™ assay showed excellent analytical sensitivity, exclusivity and clinical specificity with good clinical sensitivity using supervised NMT self-sampling. Trial registration number and registration date DRKS00021220 and 01.04.2020

2021 ◽  
Author(s):  
Lisa Johanna Krüger ◽  
Julian A.F. Klein ◽  
Frank Tobian ◽  
Mary Gaeddert ◽  
Federica Lainati ◽  
...  

Background: Rapid antigen-detecting tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can transform pandemic control. Thus far, sensitivity (≤85%) of lateral-flow assays has limited scale-up. Conceivably, microfluidic immunofluorescence Ag-RDTs could increase sensitivity for SARS-CoV-2 detection. Materials and Methods: This multi-centre diagnostic accuracy study investigated performance of the microfluidic immunofluorescence LumiraDx™ assay, enrolling symptomatic and asymptomatic participants with suspected SARS-CoV-2 infection. Participants collected a supervised nasal mid-turbinate (NMT) self-swab for Ag-RDT testing, in addition to a professionally-collected nasopharyngeal (NP) swab for routine testing with reverse transcriptase polymerase chain reaction (RT-PCR). Results were compared to calculate sensitivity and specificity. Sub-analyses investigated the results by viral load, symptom presence and duration. An analytical study assessed exclusivity and limit-of-detection (LOD). In addition, we evaluated ease-of-use. Results: Study conduct was between November 2nd 2020 and January 21st 2021. 761 participants were enrolled, with 486 participants reporting symptoms on testing day. 120 out of 146 RT-PCR positive cases were detected positive by LumiraDx™, resulting in a sensitivity of 82.2% (95% CI: 75.2%-87.5%). Specificity was 99.3% (CI: 98.3-99.7%). Sensitivity was increased in individuals with viral load ≥ 7 log10 SARS-CoV2 RNA copies/ml (93.8%; CI: 86.2%-97.3%). Testing against common respiratory commensals and pathogens showed no cross-reactivity and LOD was estimated to be 2-56 PFU/mL. The ease-of-use-assessment was favourable for lower throughput settings. Conclusion: The LumiraDx™ assay showed excellent analytical sensitivity, exclusivity and clinical specificity with good clinical sensitivity using supervised NMT self-sampling.


Author(s):  
Puck B. van Kasteren ◽  
Bas van der Veer ◽  
Sharon van den Brink ◽  
Lisa Wijsman ◽  
Jørgen de Jonge ◽  
...  

ABSTRACTThe final months of 2019 witnessed the emergence of a novel coronavirus in the human population. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has since spread across the globe and is posing a major burden on society. Measures taken to reduce its spread critically depend on timely and accurate identification of virus-infected individuals by the most sensitive and specific method available, i.e. real-time reverse transcriptase PCR (RT-PCR). Many commercial kits have recently become available, but their performance has not yet been independently assessed.The aim of this study was to compare basic analytical and clinical performance of selected RT-PCR kits from seven different manufacturers (Altona Diagnostics, BGI, CerTest Biotec, KH Medical, PrimerDesign, R-Biopharm AG, and Seegene).We used serial dilutions of viral RNA to establish PCR efficiency and estimate the 95% limit of detection (LOD95%). Furthermore, we ran a panel of SARS-CoV-2-positive clinical samples (n=16) for a preliminary evaluation of clinical sensitivity. Finally, we used clinical samples positive for non-coronavirus respiratory viral infections (n=6) and a panel of RNA from related human coronaviruses to evaluate assay specificity.PCR efficiency was ≥96% for all assays and the estimated LOD95% varied within a 6-fold range. Using clinical samples, we observed some variations in detection rate between kits. Importantly, none of the assays showed cross-reactivity with other respiratory (corona)viruses, except as expected for the SARS-CoV-1 E-gene.We conclude that all RT-PCR kits assessed in this study may be used for routine diagnostics of COVID-19 in patients by experienced molecular diagnostic laboratories.


Author(s):  
Sonny M Assennato ◽  
Allyson V Ritchie ◽  
Cesar Nadala ◽  
Neha Goel ◽  
Hongyi Zhang ◽  
...  

AbstractNucleic acid amplification for the detection of SARS-CoV-2 RNA in respiratory samples is the standard method for diagnosis. These tests are centralised and therefore turnaround times can be 2-5 days. Point-of-care testing with rapid turnaround times would allow more effective triage in settings where patient management and infection control decisions need to be made rapidly.Inclusivity and specificity of the SAMBA II SARS-CoV-2 assay was determined by in silico analyses of the primers and probes. Analytical and clinical sensitivity and specificity of the SAMBA II SARS-CoV-2 Test was evaluated for analytical sensitivity and specificity. Clinical performance was evaluated in residual clinical samples compared to the Public Health England reference tests.The limit of detection of the SAMBA II SARS-CoV-2 Test is 250 cp/mL and is specific for detection of 2 regions of the SARS-CoV-2 genome. The clinical sensitivity was evaluated in 172 clinical samples provided by the Clinical Microbiology and Public Health Laboratory, Addenbrooke’s Hospital, Cambridge (CMPHL), which showed a sensitivity of 98.9% (95% CI 94.03-99.97%), specificity of 100% (95% CI 95.55-100%), PPV of 100% and NPV of 98.78% (92.02-99.82%) compared to testing by CMPHLSAMBA detected 3 positive samples that were initially negative by PHE Test. The data shows that the SAMBA II SARS-CoV-2 Test performs equivalently to the centralised testing methods with a much quicker turnaround time. Point of care testing, such as SAMBA, should enable rapid patient management and effective implementation of infection control measures.


2021 ◽  
Author(s):  
Noah Toppings ◽  
Abu Mohon ◽  
Yoonjung Lee ◽  
Hitendra Kumar ◽  
Daniel Lee ◽  
...  

Abstract The highly infectious nature of SARS-CoV-2 necessitates the use of widespread testing to control the spread of the virus. Presently, the standard molecular testing method (reverse transcriptase-polymerase chain reaction, RT-PCR) is restricted to the laboratory, time-consuming, and costly. This increases the turnaround time for getting test results. The study sought to develop a rapid, near-patient saliva-based test for COVID-19 with similar accuracy to that of standard RT-PCR tests. A lyophilized dual-target reverse transcription-loop-mediated isothermal amplification (RT-LAMP) test with fluorometric detection by the naked eye. The assay relies on dry reagents that are room temperature stable. A device containing a centrifuge, heat block, and blue LED light system was manufactured to reduce the cost of performing the assay. This test has a limit of detection of 1 copy/µL and achieved positive percent agreement of 100% [95% CI 88.43% to 100.0%] and negative percent agreement of 96.7% [95% CI 82.78% to 99.92%] on saliva. Saliva-Dry LAMP can be completed in 105 minutes. Precision, cross-reactivity, and interfering substances analysis met international regulatory standards. The combination of ease of sample collection, dry reagents, visual detection, low capital equipment cost, and excellent analytical sensitivity make Saliva-Dry LAMP particularly useful for resource-limited settings.


2021 ◽  
Vol 7 ◽  
Author(s):  
Lin Lin ◽  
Jinshuai Guo ◽  
Haiyang Liu ◽  
Xiaofeng Jiang

A rapid, highly sensitive, and robust diagnostic technique for point-of-care (PoC) testing can be developed using the combination of the nanoparticle-based lateral flow biosensors (LFB) and isothermal nucleic acid amplification technology. Here, we developed a polymerase spiral reaction (PSR) containing FITC-labeled DNA probes coupled with the nanoparticle-based LFB assay (PSR-LFB) to detect the amplified products to detect HBV visually. Under the optimized conditions, the PSR assay involved incubation of the reaction mixture for 20 min at 63°C, followed by visual detection of positive amplicons using LFB, which would generate a red test line based on the biotin/streptavidin interaction and immunoreactions, within 5 min. A cross-reactivity test revealed that the developed PSR-LFB assay showed good specificity for HBV and could distinguish HBV from other pathogenic microorganisms. For the analytical sensitivity, the limit of detection (LoD) of PSR-LFB assay was recorded as 5.4 copies/mL of HBV genomic DNA, which was ten-times more sensitive than qPCR and loop-mediated isothermal amplification (LAMP). Additionally, all the HBV-positive (29/82) samples, identified using ELISA, were also successfully detected by the PSR-LFB assay. We found that the true positive rate of the PSR-LFB assay was higher than that of qPCR (100 vs. 89.66%, respectively), as well as the LAMP assay (100 vs. 96.55%, respectively). Furthermore, the integrated procedure could be completed in 60 min, including the processing of the blood samples (30 min), an isothermal reaction (20 min), and result visualization (5 min). Thus, this PSR-LFB assay could be a potentially useful technique for PoC diagnosis of HBV in resource-limited countries.


2020 ◽  
Author(s):  
Ben D Grant ◽  
Caitlin E Anderson ◽  
Spencer H Garing ◽  
Luis F Alonzo ◽  
John R Williford ◽  
...  

<p></p><p>Inexpensive, simple, rapid diagnostics are necessary for efficient detection, treatment and mitigation of COVID‑19. Currently, the primary diagnostic tool being utilized is reverse transcription polymerase chain reaction (RT-PCR). RT-PCR delivers results with good sensitivity and excellent specificity, but is expensive, prone to access challenges and is often slowed by transport to centralized testing laboratories. Antigen-based assays are inexpensive and can be rapidly mass-produced and deployed, with lateral flow assays (LFAs) being the most common inexpensive antigen test. To date, few antigen-detecting LFAs for COVID-19 have been commercialized. Herein, we present an open source LFA using commercially available antibodies and materials for the detection of SARS-CoV-2. Using an optical reader with comparable sensitivity to a visual read, the LFA yielded a Limit of Detection (LOD) of 23 TCID<sub>50</sub>/mL (95% CI of 9.1 to 37 TCID<sub>50</sub>/mL), equivalent to 1.4x10<sup>5</sup> copies/mL (95% CI of 5.5x10<sup>4</sup> to 2.3x10<sup>5</sup> copies/mL) irradiated virus in pooled nasal matrix. This LOD meets the criteria suggested by WHO for diagnosis of acute SARS-CoV-2 infection in a point of care format. A clinical evaluation and further testing is ongoing.</p><p></p>


2021 ◽  
Author(s):  
Percevent J Ducrest

There is an urgent need in rapid diagnostic test (RDT) to detect antigen of SARS-CoV-2 to reduce the spread of COVID-19 outbreak. We have developed a rapid and simple point-of-care lateral flow immunoassay (LFIA) detecting nucleocapsid antigen of SARS-CoV-2 in 10 minutes. The aim of this study is to evaluate the diagnostic performance and analytical sensitivity of this RDT. RT-PCR positive nasopharyngeal swab samples (n=20) for SARS-CoV-2 and 40 negative control samples were studied. Analytical sensitivity was assessed using Gamma-irradiated SARS-CoV-2 and the limit of detection (LOD) was determined at 1.4 x 10^2 TCID50/ml. Overall, RDT diagnostic sensitivity was 90% (95% confidence interval [95%CI]: 67-98%) and specificity 98% (95% CI: 85-100%). The sensitivity was 100% (95% CI: 75-100%) when using only samples with a RT-PCR Cycle threshold lower than 30. This antigen RDT displays a high diagnostic accuracy for SARS‐CoV‐2 antigen detection in high COVID‐19 prevalence settings. Its use could be considered in the absence of routine RT-PCR facilities such in low-income countries.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Noah B. Toppings ◽  
Abu Naser Mohon ◽  
Yoonjung Lee ◽  
Hitendra Kumar ◽  
Daniel Lee ◽  
...  

AbstractThe highly infectious nature of SARS-CoV-2 necessitates the use of widespread testing to control the spread of the virus. Presently, the standard molecular testing method (reverse transcriptase-polymerase chain reaction, RT-PCR) is restricted to the laboratory, time-consuming, and costly. This increases the turnaround time for getting test results. This study sought to develop a rapid, near-patient saliva-based test for COVID-19 (Saliva-Dry LAMP) with similar accuracy to that of standard RT-PCR tests. A lyophilized dual-target reverse transcription-loop-mediated isothermal amplification (RT-LAMP) test with fluorometric detection by the naked eye was developed. The assay relies on dry reagents that are room temperature stable. A device containing a centrifuge, heat block, and blue LED light system was manufactured to reduce the cost of performing the assay. This test has a limit of detection of 1 copy/µL and achieved a positive percent agreement of 100% [95% CI 88.43% to 100.0%] and a negative percent agreement of 96.7% [95% CI 82.78–99.92%] relative to a reference standard test. Saliva-Dry LAMP can be completed in 105 min. Precision, cross-reactivity, and interfering substances analysis met international regulatory standards. The combination of ease of sample collection, dry reagents, visual detection, low capital equipment cost, and excellent analytical sensitivity make Saliva-Dry LAMP particularly useful for resource-limited settings.


2013 ◽  
Vol 59 (4) ◽  
pp. 641-648 ◽  
Author(s):  
Christina Swanson ◽  
Annalisa D'Andrea

BACKGROUND Lateral flow assays (LFAs) are popular point-of-care diagnostic tools because they are rapid and easy to use. Nevertheless, they often lack analytical sensitivity and quantitative output and may be difficult to multiplex, limiting their usefulness in biomarker measurement. As a proof-of-concept study, we detail the design of a quantitative, multiplex LFA with readily available near-infrared (NIR) detection to improve analytical sensitivity. METHODS NIR dye was conjugated to selected antibodies and incorporated into LFAs. We used singleplex, optimized NIR-LFAs to measure interleukin (IL)-6 from 0 to 200 pg/mL and developed duplex assays to simultaneously measure IL-6 from 0 to 100 pg/mL (0 to 4.5 pmol/L) and C-reactive protein (CRP) from 50 to 2500 ng/mL (0.4 to 20 nmol/L) on a single test strip. Assays were tested on 60 different spiked samples and compared to ELISA results. RESULTS NIR-LFAs detected IL-6 in a 10% plasma matrix with a limit of detection of 4 pg/mL (182 fmol/L) and a CV &lt;7%. Duplex NIR-LFAs quantitatively measured IL-6 and CRP concentrations simultaneously. Values strongly correlated to ELISA measurements, with R2 values of 0.9825 and 0.9711 for IL-6 and CRP, respectively. CONCLUSIONS NIR-LFAs exhibit quantitative measurement at pg/mL concentrations owing to a high signal-to-BACKGROUND ratio and robust detection antibody clearance through the test strip. Moreover, NIR-LFAs are able to detect molecules present at vastly different concentrations in multiplex format and compare favorably to ELISAs. LFAs with direct NIR detection may be a valuable tool for biomarker evaluation in the point-of-care setting.


2020 ◽  
Author(s):  
Ben D Grant ◽  
Caitlin E Anderson ◽  
Spencer H Garing ◽  
Luis F Alonzo ◽  
John R Williford ◽  
...  

<p></p><p>Inexpensive, simple, rapid diagnostics are necessary for efficient detection, treatment and mitigation of COVID‑19. Currently, the primary diagnostic tool being utilized is reverse transcription polymerase chain reaction (RT-PCR). RT-PCR delivers results with good sensitivity and excellent specificity, but is expensive, prone to access challenges and is often slowed by transport to centralized testing laboratories. Antigen-based assays are inexpensive and can be rapidly mass-produced and deployed, with lateral flow assays (LFAs) being the most common inexpensive antigen test. To date, few antigen-detecting LFAs for COVID-19 have been commercialized. Herein, we present an open source LFA using commercially available antibodies and materials for the detection of SARS-CoV-2. Using an optical reader with comparable sensitivity to a visual read, the LFA yielded a Limit of Detection (LOD) of 23 TCID<sub>50</sub>/mL (95% CI of 9.1 to 37 TCID<sub>50</sub>/mL), equivalent to 1.4x10<sup>5</sup> copies/mL (95% CI of 5.5x10<sup>4</sup> to 2.3x10<sup>5</sup> copies/mL) irradiated virus in pooled nasal matrix. This LOD meets the criteria suggested by WHO for diagnosis of acute SARS-CoV-2 infection in a point of care format. A clinical evaluation and further testing is ongoing.</p><p></p>