Influence of Hydrocarbon Concentration on Biocorrosion of Carbon Steel by Bacillus megaterium in Produced Water System

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Ardiyan Harimawan ◽  
Hary Devianto ◽  
Christian Aslan ◽  
Eric Hansel
2021 ◽  
Author(s):  
Steinar Asdahl ◽  
Johann Jansen van Rensburg ◽  
Martin Einarson Waag ◽  
Rune Glenna Nilssen

Abstract Traditionally, produced water from production separators is handled by multiple steps and different technologies in order to meet the required quality for either discharge or reinjection of the water. The development of the latest Compact Flotation Unit (CFU) technology has unlocked the potential for savings on cost, complexity, footprint and weight for the produced water treatment system. The developed CFU technology has proven applicable through field testing as a single treatment technology for reducing Oil-in-Water (OiW) content directly from tie-in at separator and still meet stringent requirements for outlet OiW quality. Field tests were conducted with inlet OiW concentration ranging from 200-2000 ppm, achieving results in the range 2.5 to 21 ppm only with a two-stage latest generation CFU. Compared to a traditional produced water system setup consisting of de-oiling hydrocyclones and a horizontal degassing vessel, the savings in footprint and operational weight is estimated to 54 % and 53 % respectively utilizing a two-stage CFU for a system with a design capacity of 76.000 BWPD. Furthermore, the development of the latest generation CFU technology has enabled the retrofit concept, incorporating the developed CFU internals into existing gravity separation based produced water vessels, converting them to more efficient flotation vessels with increased capacity. For brownfield and debottlenecking applications, operators are challenged by increasing water cut from maturing wells, and as a result exceeding the facilities design capacity for produced water treatment. This challenge is often further reinforced by increasingly stricter environmental legislation for OiW content for discharge or re-injection. The retrofit concept will offer a highly cost-, footprint- and weight-efficient solutions to these challenges utilizing existing vessels. Benefits of the retrofit concept: Bring proven and unique performance of the technology to other produced water separation vessels helping the operators improve the separation efficiency and increase throughput while meeting discharge requirementsShort execution time compared to installation of new process equipmentLow cost compared to installation of new process equipmentUtilization of existing equipment saves valuable footprint.


Author(s):  
Yustina Metanoia Pusparizkita ◽  
Wolfgang Schmahl ◽  
Tjandra Setiadi ◽  
Bork Ilsemann ◽  
Mike Reich ◽  
...  

2021 ◽  
Vol 23 (12) ◽  
pp. 375-386
Author(s):  
Mahmoud Abbas ◽  
◽  
M. A. Shahin ◽  
Mohamed M. I. Ahmed ◽  
Magdy Kasem ◽  
...  

It is well know that recirculating open cooling water system at metal/ water surface contact appear frequent corrosion products, like scales, foaling and material losses which are have great effect on cooling process. Passivation helps to maintain clean heat transfer surface by inhibiting oxides scales through creating outer passive layer. Passivators are substances which usually have a sufficiently high equilibrium potential and sufficiently low over potential decrease corrosion rate on attainment of passivity. One of the most popular passivator is organic phosphate Phosphinosuccinic oligomer C15H14O4P component (PSO) The study of passivation of carbon steel pipe line in recirculating open cooling water system was the aim of this present work. Maximum efficiency of passivator was determined and surface morphology were investigated using optical, scanning microscopy, phase analysis of the formed protective layer was exam by XRD and EDX. Corrosion in running water with and without PSO at 2 m3/hr flow rate was investigated using corrosion coupon rack. It was found that 200 ppm (PSO) decreases corrosion rate of carbon steel pipe in 3.5% NaCL solution from 23 to 7 mpy in stagnate water corrosion testing, while in running water in 3.5% NaCL solution it decreases from 45 to 18 mpy. XDR showed that the protective layer due to passivation is mainly Magnetite (Fe3O4) compound.


2021 ◽  
Vol 12 (4) ◽  
pp. 5698-5708

Microorganisms in biodiesel storage tanks may generate bio-corrosion due to their hygroscopic and susceptible fuel degradation. The organisms, including Bacillus megaterium present in the hydrocarbons, resulted from the EPS and metabolites processes that subsequently control the corrosion process of the tank. This present study examined the effect of biodiesel concentration on microbial activity through TPC analyzing growth for B. megaterium. Furthermore, this study investigated EPS formation and acid metabolites production by B. megaterium based on SEM observations and acidimetric titration. Meanwhile, this study investigated the microorganism-induced corrosion impact based on gravimetric analysis. The results explained a higher biodiesel concentration in diesel oil promoted an increase in the growth of B. megaterium and the corrosion rate. Conversely, the acid metabolites produced from bacteria under the biofilm did not significantly increase the corrosion rate. Corrosion products resulting from the B. megaterium activity on the surface of the steel included Iron (II, III) oxide (Fe2O3 and Fe3O4). The formation of oxide and pitting may control the strength of the surface tank in the course of biofuel storage, which may lead to the failure of the material.


2020 ◽  
pp. 46-52
Author(s):  
F.F. Veliyev ◽  

Methanol solutions of various concentrations have been developed based on synthesized N, Nʹ- (pirazin-2-il) pyridine - 2,6-diamine ligand (N5-2pz), its linear pentanuclear of nickel string (II) [Ni5(μ5-dpzpda)4Cl2] (Ni5-N5-2pz) and tetracyclic copper complex (II) [Cu4(Hdpzpda)2(CH3COO)6] (Cu4-N5-2pz). Anticorrosion impact of these solutions on carbon steel Сt20 was studied on the model of produced water saturated with carbon dioxide (CO2) in the medium of hydrogen sulphide with different concentrations (H2S). Biocide properties of developed solutions against corrosion bacteria (sulphate-reducing bacteria, Tionand hydrocarbon oxidizing bacteria) have been studied on the samples of produced water taken from flooded production wells of “Bibiheybat” OGPD as well and good results obtained.


2011 ◽  
Vol 80 (3) ◽  
pp. 440-445 ◽  
Author(s):  
Václav Čuba ◽  
Rostislav Silber ◽  
Viliam Múčka ◽  
Milan Pospíšil ◽  
Soběslav Neufuss ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document