scholarly journals Folding photopolymerized origami sheets by post-curing

2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Xiaodong He ◽  
Christopher-Denny Matte ◽  
Tsz-Ho Kwok

AbstractThe paper presents a novel manufacturing approach to fabricate origami based on 3D printing utilizing digital light processing. Specifically, we propose to leave part of the model uncured during the printing step, and then cure it in the post-processing step to set the shape in a folded configuration. While the cured regions in the first step try to regain their unfolded shape, the regions cured in the second step attempt to keep their folded shape. As a result, the final shape is obtained when both regions’ stresses reach equilibrium. Finite element analysis is performed in ANSYS to obtain the stress distribution on common hinge designs, demonstrating that the square-hinge has a lower maximum principal stress than elliptical and triangle hinges. Based on the square-hinge and rectangular cavity, two variables—the hinge width and the cavity height—are selected as principal variables to construct an empirical model with the final folding angle. In the end, experimental verification shows that the developed method is valid and reliable to realize the proposed deformation and 3D development of 2D hinges.

2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Tarcisio José de Arruda Paes Junior ◽  
João Paulo Mendes Tribst ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Viviane Maria Gonçalves de Figueiredo ◽  
Alexandre Luiz Souto Borges ◽  
...  

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain.   Keywords Finite element analysis; Occlusion; Total prosthesis.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1923
Author(s):  
Ana Beatriz Gomes de Carvalho ◽  
‪Guilherme Schmitt de Andrade ◽  
João Paulo Mendes Tribst ◽  
Elisa Donária Aboucauch Grassi ◽  
Pietro Ausiello ◽  
...  

This study evaluated the effect of the combination of three different onlay preparation designs and two restorative materials on the stress distribution, using 3D-finite element analysis. Six models of first lower molars were created according to three preparation designs: non-retentive (nRET), traditional with occlusal isthmus reduction (IST), and traditional without occlusal isthmus reduction (wIST); and according to two restorative materials: lithium-disilicate (LD) and nanoceramic resin (NR). A 600 N axial load was applied at the central fossa. All solids were considered isotropic, homogeneous, and linearly elastic. A static linear analysis was performed, and the Maximum Principal Stress (MPS) criteria were used to evaluate the results and compare the stress in MPa on the restoration, cement layer, and tooth structure (enamel and dentin). A novel statistical approach was used for quantitative analysis of the finite element analysis results. On restoration and cement layer, nRET showed a more homogeneous stress distribution, while the highest stress peaks were calculated for LD onlays (restoration: 69–110; cement layer: 10.2–13.3). On the tooth structure, the material had more influence, with better results for LD (27–38). It can be concluded that nRET design showed the best mechanical behavior compared to IST and wIST, with LD being more advantageous for tooth structure and NR for the restoration and cement layer.


2014 ◽  
Vol 15 (4) ◽  
pp. 444-450 ◽  
Author(s):  
César Dalmolin Bergoli ◽  
Rodrigo Furtado de Carvalho ◽  
Ivan Balducci ◽  
Josete Barbosa Cruz Meira ◽  
Maria Amélia Máximo de Araújo ◽  
...  

ABSTRACT Aim This study aims to evaluate, the influence of different fiber posts cementation lengths by finite element analysis (FEA) and coronal microleakage. Materials and methods Fifty anterior bovine teeth were sectioned to obtain roots with 16 mm length. The coronal length of the post was 6 mm for all groups, while the radicular length were varied 6, 8, 10 or 12 mm. The fiber posts surfaces were cleaned with alcohol and silanized. Then the posts were cemented using a two steps total etch-and-rinse adhesive system + conventional resin cement. Forty teeth were submitted to mechanical cycling (45°; 2.000.000 cycles; 90N; 4Hz; 37°C) and ten teeth with radicular length of 12 mm was not submitted, serving as control. So, the experimental design was composed by different ratios of post coronal length/post radicular length and mechanical cycling (MC): Gr1- 1/1 + MC; Gr2- 3/4 + MC; Gr3- 3/5 + MC; Gr4- 1/2 + MC. All groups were immersed in a 1% toluidine blue solution. After 24 hours, the teeth were longitudinally sectioned and the microleakage scores was given by a blind operator. Data were submitted to Kruskal-Wallis test (p = 0.05). The experimental variables were simulated in twodimensional finite element analysis (2D-FEA). The maximum principal stress distributions were compared. Results No difference was observed in microleakage values between the cycled groups, whilst the control groups showed the lowest values. FEA analysis showed similar maximum principal stress distribution between the groups. Conclusion Mechanical cycling affected the values of coronal microleakage and different cementation length generated similar values of coronal microleakage and stress distribution. Clinical significance These results showed that from the microleakage point of view, more conservative cementation lengths have the same effect as longer cementation lengths. How to cite this article Bergoli CD, de Carvalho RF, Balducci I, Meira JBC, de Araújo MAM, Valera MC. Influence of Fiber Post Cementation Length on Coronal Microleakage Values in vitro and Finite Element Analysis. J Contemp Dent Pract 2014; 15(4):444-450.


2020 ◽  
Vol 1 (1) ◽  
pp. 11761
Author(s):  
Felipe De Souza Matos ◽  
Thaís Christina Cunha ◽  
Ayla Macyelle De Oliveira Correia ◽  
João Paulo Mendes Tribst ◽  
Taciana Marco Ferraz Caneppele ◽  
...  

The aim of this study was to investigate, through finite element analysis, the impact of different restorative techniques on stress distribution in endodontically-treated maxillary first premolars. A human maxillary first premolar was modeled following the real anatomical dimensions, through a periapical radiography, using the Rhinoceros software, version 4.0SR8. The model was then replicated to compose the groups according to the coronary restorative technique: C (coltosol), GI.C (glass ionomer + coltosol), GI (glass ionomer), CR.GI (conventional resin + glass ionomer), and BR.GI (Bulk Fill resin + glass ionomer). After the models were finished, they were imported as IGES files into ANSYS software, version 17.2. Fixation was defined at the base of the cortical bone and the load was applied with 300 N axially to the buccal and palatal cusps. The results generated were in maximum principal stress (MPS), with the CR.GI and BR.GI groups presenting the lowest values of tension concentration and more homogeneous stress distribution, followed by GI, GI.C and C. All restorative techniques affected the stress distribution in endodontically-treated maxillary first premolars, promoting greater tension in the occlusal third, at the interface with the buccal wall, and in the cervical third. Conventional or Bulk Fill resins associated with a glass ionomer base have a superior biomechanical behavior in relation to coltosol or glass ionomer.


2013 ◽  
Vol 39 (5) ◽  
pp. 575-581 ◽  
Author(s):  
Mateus Bertolini Fernandes dos Santos ◽  
Rafael Leonardo Xediek Consani ◽  
Marcelo Ferraz Mesquita

The aim of this study was to evaluate the stress distribution in the bone adjacent to submerged implants during masticatory function in conventional complete dentures with different soft liners through finite element analysis. Three-dimensional models of a severely resorbed mandible with 2 and 4 submerged implants in the anterior region were created and divided into the following situations: (1) conventional complete dentures (control group); and conventional complete dentures with different soft liner materials, (2) Coe-Comfort, (3) Softliner, and (4) Molteno Hard. The models were exported to mechanical simulation software and 2 simulations were done with the load in the inferior right canine (35 N) and the inferior right first molar (50 N). The data were qualitatively evaluated using the maximum principal stress and microstrain values given by the software. The use of soft liners provides decreased levels of stress and microstrains in peri-implant bone when the load was applied to canine teeth. Considering all of the values obtained in this study, the use of softer materials is the most suitable for use during the period of osseointegration.


2019 ◽  
Vol 68 (3) ◽  
Author(s):  
João P. Tribst ◽  
Bianca M. Kohn ◽  
Amanda M. de Oliveira Dal Piva ◽  
Manuela S. Spinola ◽  
Alexandre L. Borges ◽  
...  

2021 ◽  
Vol 11 (3) ◽  
pp. 1220
Author(s):  
Azeem Ul Yaqin Syed ◽  
Dinesh Rokaya ◽  
Shirin Shahrbaf ◽  
Nicolas Martin

The effect of a restored machined hybrid dental ceramic crown–tooth complex is not well understood. This study was conducted to determine the effect of the stress state of the machined hybrid dental ceramic crown using three-dimensional finite element analysis. Human premolars were prepared to receive full coverage crowns and restored with machined hybrid dental ceramic crowns using the resin cement. Then, the teeth were digitized using micro-computed tomography and the teeth were scanned with an optical intraoral scanner using an intraoral scanner. Three-dimensional digital models were generated using an interactive image processing software for the restored tooth complex. The generated models were imported into a finite element analysis software with all degrees of freedom concentrated on the outer surface of the root of the crown–tooth complex. To simulate average occlusal load subjected on a premolar a total load of 300 N was applied, 150 N at a buccal incline of the palatal cusp, and palatal incline of the buccal cusp. The von Mises stresses were calculated for the crown–tooth complex under simulated load application was determined. Three-dimensional finite element analysis showed that the stress distribution was more in the dentine and least in the cement. For the cement layer, the stresses were more concentrated on the buccal cusp tip. In dentine, stress was more on the cusp tips and coronal 1/3 of the root surface. The conventional crown preparation is a suitable option for machined polymer crowns with less stress distribution within the crown–tooth complex and can be a good aesthetic replacement in the posterior region. Enamic crowns are a good viable option in the posterior region.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1654
Author(s):  
Poojitha Vurtur Badarinath ◽  
Maria Chierichetti ◽  
Fatemeh Davoudi Kakhki

Current maintenance intervals of mechanical systems are scheduled a priori based on the life of the system, resulting in expensive maintenance scheduling, and often undermining the safety of passengers. Going forward, the actual usage of a vehicle will be used to predict stresses in its structure, and therefore, to define a specific maintenance scheduling. Machine learning (ML) algorithms can be used to map a reduced set of data coming from real-time measurements of a structure into a detailed/high-fidelity finite element analysis (FEA) model of the same system. As a result, the FEA-based ML approach will directly estimate the stress distribution over the entire system during operations, thus improving the ability to define ad-hoc, safe, and efficient maintenance procedures. The paper initially presents a review of the current state-of-the-art of ML methods applied to finite elements. A surrogate finite element approach based on ML algorithms is also proposed to estimate the time-varying response of a one-dimensional beam. Several ML regression models, such as decision trees and artificial neural networks, have been developed, and their performance is compared for direct estimation of the stress distribution over a beam structure. The surrogate finite element models based on ML algorithms are able to estimate the response of the beam accurately, with artificial neural networks providing more accurate results.


Sign in / Sign up

Export Citation Format

Share Document