Visual illusions without low spatial frequencies

1984 ◽  
Vol 24 (10) ◽  
pp. 1407-1413 ◽  
Author(s):  
C.R. Carlson ◽  
J.R. Moeller ◽  
C.H. Anderson
Author(s):  
Aude Oliva ◽  
Philippe G. Schyns

Artists, designers, photographers, and visual scientists are routinely looking for ways to create, out of a single image, the feeling that there is more to see than what meets the eye. Many well-known visual illusions are dual in nature, causing the viewer to experience two different interpretations of the same image. Hybrid images illustrate a double-image illusion, where different images are perceived depending on viewing distance, viewing duration, or image size: one that appears when the image is viewed up-close (displaying high spatial frequencies) and another that appears from afar (showing low spatial frequencies). This method can be used to create compelling dual images in which the observer experiences different percepts when interacting with the image.


Author(s):  
J.M. Cowley

The problem of "understandinq" electron microscope imaqes becomes more acute as the resolution is improved. The naive interpretation of an imaqe as representinq the projection of an atom density becomes less and less appropriate. We are increasinqly forced to face the complexities of coherent imaqinq of what are essentially phase objects. Most electron microscopists are now aware that, for very thin weakly scatterinq objects such as thin unstained bioloqical specimens, hiqh resolution imaqes are best obtained near the optimum defocus, as prescribed by Scherzer, where the phase contrast imaqe qives a qood representation of the projected potential, apart from a lack of information on the lower spatial frequencies. But phase contrast imaqinq is never simple except in idealized limitinq cases.


Author(s):  
Henry I. Smith ◽  
D.C. Flanders

Scanning electron beam lithography has been used for a number of years to write submicrometer linewidth patterns in radiation sensitive films (resist films) on substrates. On semi-infinite substrates, electron backscattering severely limits the exposure latitude and control of cross-sectional profile for patterns having fundamental spatial frequencies below about 4000 Å(l),Recently, STEM'S have been used to write patterns with linewidths below 100 Å. To avoid the detrimental effects of electron backscattering however, the substrates had to be carbon foils about 100 Å thick (2,3). X-ray lithography using the very soft radiation in the range 10 - 50 Å avoids the problem of backscattering and thus permits one to replicate on semi-infinite substrates patterns with linewidths of the order of 1000 Å and less, and in addition provides means for controlling cross-sectional profiles. X-radiation in the range 4-10 Å on the other hand is appropriate for replicating patterns in the linewidth range above about 3000 Å, and thus is most appropriate for microelectronic applications (4 - 6).


Author(s):  
K.-H. Herrmann ◽  
E. Reuber ◽  
P. Schiske

Aposteriori deblurring of high resolution electron micrographs of weak phase objects can be performed by holographic filters [1,2] which are arranged in the Fourier domain of a light-optical reconstruction set-up. According to the diffraction efficiency and the lateral position of the grating structure, the filters permit adjustment of the amplitudes and phases of the spatial frequencies in the image which is obtained in the first diffraction order.In the case of bright field imaging with axial illumination, the Contrast Transfer Functions (CTF) are oscillating, but real. For different imageforming conditions and several signal-to-noise ratios an extensive set of Wiener-filters should be available. A simple method of producing such filters by only photographic and mechanical means will be described here.A transparent master grating with 6.25 lines/mm and 160 mm diameter was produced by a high precision computer plotter. It is photographed through a rotating mask, plotted by a standard plotter.


Author(s):  
Joachim Frank

Compared with images of negatively stained single particle specimens, those obtained by cryo-electron microscopy have the following new features: (a) higher “signal” variability due to a higher variability of particle orientation; (b) reduced signal/noise ratio (S/N); (c) virtual absence of low-spatial-frequency information related to elastic scattering, due to the properties of the phase contrast transfer function (PCTF); and (d) reduced resolution due to the efforts of the microscopist to boost the PCTF at low spatial frequencies, in his attempt to obtain recognizable particle images.


Author(s):  
Gregor Volberg

Previous studies often revealed a right-hemisphere specialization for processing the global level of compound visual stimuli. Here we explore whether a similar specialization exists for the detection of intersected contours defined by a chain of local elements. Subjects were presented with arrays of randomly oriented Gabor patches that could contain a global path of collinearly arranged elements in the left or in the right visual hemifield. As expected, the detection accuracy was higher for contours presented to the left visual field/right hemisphere. This difference was absent in two control conditions where the smoothness of the contour was decreased. The results demonstrate that the contour detection, often considered to be driven by lateral coactivation in primary visual cortex, relies on higher-level visual representations that differ between the hemispheres. Furthermore, because contour and non-contour stimuli had the same spatial frequency spectra, the results challenge the view that the right-hemisphere advantage in global processing depends on a specialization for processing low spatial frequencies.


2019 ◽  
Vol 133 (4) ◽  
pp. 417-418
Author(s):  
Todd M. Freeberg
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document