Experimental Evaluation of a Heat Pump Air Conditioner Using R13B1/R152a Refrigerant Mixture

Heat Pumps ◽  
1990 ◽  
pp. 497-502
Author(s):  
Kazuaki Minato ◽  
Kenji Matsuki
2021 ◽  
pp. 102585
Author(s):  
Kasni Sumeru ◽  
Mohamad Firdaus Sukri ◽  
Triaji Pangripto Pramudantoro ◽  
Eddy Erham ◽  
Rizki Muliawan

Author(s):  
T. Kiatsiriroat ◽  
T. Euakit

In this paper the irreversibilities and second law efficiency of an automobile air-conditioner with R22/R124/R152a refrigerant blend have been carried out. The engine is 1,300 c.c. capacity and operated at different compressor speeds between 13–55 rps. The irreversibility at each component of the air-conditioner increases with higher compressor speed. Significant irreversibilities have been found at the condenser and the compressor. In the case of the cycle second law efficiency, the unit with 30% mass fraction of R22 shows better performance than those with 20 and 40% mass fraction.


2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


1983 ◽  
Vol 7 (2) ◽  
pp. 129-135
Author(s):  
S. E. Ogbeide ◽  
S. A. K. El-Meniawy ◽  
S. Devotta ◽  
F. A. Watson ◽  
F. A. Holland

2013 ◽  
Vol 475-476 ◽  
pp. 192-197
Author(s):  
Jian Wen Feng ◽  
Li Peng Wang

Performance test-bed of heat pump unit in central air-conditioner needs the intelligent and multifunctional software. So the monitoring software is designed with a good human-machine interactive interface, based on Visual C# development platform. The software can dynamically configure channels and measurement points to improve the defects of fixed channels for all measuring points in the traditional monitoring systems, which enhanced the flexibility and reliability of system. In order to increase the data accuracy, the improved digital filter algorithm was adopted. In addition, multi-threading mechanism was used to achieve serial communication and data processing, which meets the requirements of monitoring program for multi-tasking and real-time. The results show that monitoring software is powerful, easy to operate, reliable, high fault-tolerant and good user-friendly. It is suitable for using in other monitoring systems.