Experimental Investigation on Flow Characteristic of Stepped Capillary Tube for Heat Pump Type Air Conditioner with R410A

2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.

2014 ◽  
Vol 22 (04) ◽  
pp. 1450022 ◽  
Author(s):  
CHI ZHANG ◽  
YING WANG ◽  
JIANGPING CHEN

Mal-distribution of refrigerant in a cross-flow type evaporator with parallel paths is very important, which can lead to a loss of heat exchanger capacity to 25%. Distributors are used to balance the two-phase refrigerant distributions in each path. Apart from the structural factors, there are other factors influencing the performance of distributor greatly. In this paper, influences of several nonstructural factors on reservoir distributor are investigated experimentally under varied working conditions. The inlet tube configuration, installation orientation and capillary tube length are also studied. One experiment apparatus is developed to measure the refrigerant mass flow rate and the quality based on R410A air conditioner. It is found that influence caused by inlet tube before the distributor is small. The average STD is only 2.76%. Influence caused by orientation is broad. The average STD is less than 9% on the orientation of 15°. On the orientation of 90°, STDs of different conditions are all more than 40%. For orientation, mass flow rate sensitivity is larger than quality sensitivity. Capillary tubes with different length can be used to adjust distribution. Average STD with sizable capillary length difference is 9.47%. It means that only small mal-distribution can be adjusted by using different-length capillary tubes. Capillary tube length sensitivity increases with the increase of difference between outlet tubes or the decrease of average length of outlet tubes.


2015 ◽  
Vol 23 (02) ◽  
pp. 1550015 ◽  
Author(s):  
Ahmad Sharifian ◽  
Jeri Tangalajuk Siang

The performance of a portable propane air conditioner system, in which the temperatures of the air passing over the condenser and evaporator are equal, has been experimentally investigated under different room temperatures and refrigerant charge levels. The research has been carried out in a range of room temperatures from 20°C to 35°C and in undercharge, standard charge and overcharge conditions. The results show that, at higher room temperatures, the refrigerant temperature in all parts of the system, the density of the refrigerant at the inlet and outlet of the condenser, mass of the refrigerant in the compressor, the mass flow rate of the refrigerant and the cooling capacity of the system in either the undercharge or full charge condition, the specific cooling capacity of the undercharge system, the useful work of the compressor, and the maximum pressure of the refrigerant increase. The increase in room temperature decreases the density of the refrigerant at the inlet and outlet of the capillary tube, the mass of the refrigerant in the capillary tube, the refrigerant subcooling at the inlet of the capillary tube, the maximum velocity of the refrigerant and the coefficient of performance. In addition, the increase in room temperature at overcharge condition causes an increase in the mass flow rate, cooling capacity and specific cooling capacity to a maximum value followed by their decrease. The most important difference between a portable air conditioner and a nonportable system is the increase in cooling capacity with an increase in room temperature in full charge condition.


1996 ◽  
Vol 118 (1) ◽  
pp. 150-154 ◽  
Author(s):  
Tuncay Yilmaz ◽  
Saban U¨nal

Capillary tubes are used widely in small refrigeration systems. It is necessary to design the capillary tube, but there does not exist any analytical equation which allows the determination of capillary tube length or mass flow rate for all refrigerants. In this work, an analytical equation is derived which allows to design the capillary tubes. The comparison with existing methods and experimentally obtained values using the refrigerants R12, R22, R113, R114, R134a, and R600a has turned out to be satisfactory.


2017 ◽  
Vol 25 (04) ◽  
pp. 1730004 ◽  
Author(s):  
Mehdi Rasti ◽  
Ji Hwan Jeong

Capillary tubes are widely used as expansion devices in small-capacity refrigeration systems. Since the refrigerant flow through the capillary tubes is complex, many researchers presented empirical dimensionless correlations to predict the refrigerant mass flow rate. A comprehensive review of the dimensionless correlations for the prediction of refrigerants mass flow rate through straight and coiled capillary tubes depending on their geometry and adiabatic or diabatic capillary tubes depending on the flow configurations has been discussed. A comprehensive review shows that most of previous dimensionless correlations have problems such as discontinuity at the saturated lines or ability to predict the refrigerant mass flow rate only for the capillary tube subcooled inlet condition. The correlations suggested by Rasti et al. and Rasti and Jeong appeared to be general and continuous and these correlations can be used to predict the refrigerant mass flow rate through all the types of capillary tubes with wide range of capillary tube inlet conditions including subcooled liquid, two-phase mixture, and superheated vapor conditions.


SINERGI ◽  
2020 ◽  
Vol 24 (2) ◽  
pp. 81
Author(s):  
Dedik Romahadi ◽  
Nanang Ruhyat ◽  
L. B. Desti Dorion

The use of condensers in air conditioning units is more common in large-capacity units than in ones with a smaller capacity. Air conditioning provides comfort and freshness to an air-conditioned room. It should be noted that each room has a different heat load, which affects the specifications of the condenser used. The accuracy with which appropriate condenser specifications are determined affects the performance of the air conditioner. Thus, considering how important condenser needs are, it is necessary to design condensers with optimal performance, which adhere to proven standards. To achieve this, the design of a condenser should be based on the results of the smallest condenser dimensions of three types of surfaces, as they are intended for a limited place. This condenser design uses the standard dimensions of the Kays and London charts. Data is collected by measuring the results of temperature and enthalpy of a refrigerant at desuperheating and condensation, inlet air temperature, outlet air temperature, refrigerant mass flow rate, and air mass flow rate. The results of the compact condenser design are based on existing data, which is obtained from the smallest design results. The result uses the type of Surface CF-8.72(c) with a heat transfer area of 0.259 m2, a total tube length of 9.5 m, crossing tube length 0.594 m and a pressure drop of 3778 Pascal (Pa) on the side of a tube. This design fulfills the stipulated requirements, as the pressure drop is less than the specified maximum limit in most units.


Author(s):  
A. Nouri-Borujerdi ◽  
P. Javidmand

This paper presented a numerical study that predicts critical mass flow rate, pressure, vapor quality, and void fraction along a very long tube with small diameter or capillary tub under critical condition by the drift flux model. Capillary tubes are simple expansion devices and are necessary to design and optimization of refrigeration systems. Using dimensional analysis by Buckingham’s π theory, some generalized correlations are proposed for prediction of flow parameters as functions of flow properties and tube sizes under various critical conditions. This study is performed under the inlet pressure in the range of 0.8 ≤ pin ≤ 1.5Mpa, subcooling temperature between 0 ≤ ΔTsub ≤ 10 °C. The tube diameter is in the range of 0.5 ≤ D ≤ 1.5mm and tube length between 1 ≤ L ≤ 2m for water, ammonia, refrigerants R-12, R-22 and R-134 as working fluids. Comparison between the results of the present work and some experimental data indicates a good agreement. Cluster of data close to the fitted curves also shows satisfactory results.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3133
Author(s):  
Hongzhi Liu ◽  
Katsunori Nagano ◽  
Takao Katsura ◽  
Yue Han

In this study, a heat pump of 10 kW with vapor injection using refrigerant of R410A was developed. A vapor injection pipe connecting a gas–liquid separator at the outlet of the main expansion valve and the suction of a single-stage rotary compressor was designed. The heating performance of this vapor injection heat pump was investigated and analyzed at different compressor frequencies and primary temperatures. The experimental results show that for the heat pump without vapor injection, the heating capacity increased linearly with the compressor frequency, while the heating coefficient of performance (COP) decreased linearly with the compressor frequency for each tested primary temperature. The developed vapor injection technique is able to increase the heat pump system’s heating capacity and heating COP when the injection ratio R falls into the range 0.16–0.17. The refrigerant mass flow rate can be increased in the vapor injection heat pump cycle due to the decreased specific volume of the suction refrigerant. The power consumption of vapor injection heat pump cycle almost remains the same with that of the conventional heat pump cycle because of the increased refrigerant mass flow rate and the decreased compression ratio. Finally, it was found that the developed vapor injection cycle is preferable to decreasing the compressor’s discharge temperature.


2019 ◽  
Vol 27 (01) ◽  
pp. 1950001 ◽  
Author(s):  
Praveen Alok ◽  
Debjyoti Sahu

In this work, a set of computational investigation results of two-phase refrigerant flow through adiabatic capillary are presented. There are various sizes of capillary tubes that can be selected related to commercially available copper tubes. Earlier refrigerants and new refrigerants like R12, R22, R134a, R410A and R32 are used for the flow analysis. Homogeneous-equilibrium model is employed with user-defined properties of the refrigerants for computation using ANSYS CFX. Several important parameters can be predicted rapidly and accurately using this method such as refrigerant mass flow rate, vapor mass fraction, local Mach no. etc. The mean deviation in mass flow rate is found to be [Formula: see text]1.18% for the same length of capillary tube and the mean deviation of tube length is found to be [Formula: see text]1.48% for the same experimental mass flow rate with choked flow condition.


2020 ◽  
Vol 28 (03) ◽  
pp. 2050024
Author(s):  
Pravin Jadhav ◽  
Neeraj Agrawal

The flow characteristics of CO2 refrigerant are numerically studied for an adiabatic spirally coiled capillary tube employing choked flow conditions. The mass, momentum and energy conservation equations are used to develop a numerical model. The existing model is verified with the published results. The choked flow behavior at various geometric parameters viz. tube diameter and spiral pitch is studied. Similarly, the influence of these parameters on the mass flow rate through the tube is observed. A significant change in mass flow rate is due to a change in tube diameter, whereas a minimal variation is observed with the change in surface roughness and spiral pitch. Moreover, it is observed that the coiling effect has a significant influence on the flow behavior of the spiral capillary tube. As the pressure decreases, from unchoked to the choked pressure in the evaporator by 63.46%, the mass flow rate increases by 9.46% only. The capillary tube choking is circumvented by increasing spiral pitch, tube diameter and decreasing the length of the tube. A unique nomogram is developed that gives the best understanding of choked and unchoked flow conditions, that graphical representation is useful to design the spirally coiled capillary tube. By using that, the choked length is identified for the known mass flow rate, even more, the choked mass flow rate is known for a given tube length. Moreover, for the given tube length and evaporator temperature, a nomogram is useful to the known choked values of mass flow rate and exit values of the evaporator pressure and quality of refrigerant.


2014 ◽  
Vol 7 (2) ◽  
pp. 47-60
Author(s):  
Abdul- Kareem R. Abed ◽  
Hassan Jawdat Fadhiel ◽  
Gaydaa Mahsun ◽  
Thabet C. Yassen

A domestic refrigerator of 5 ft3 capacity is used to study the effect of coiled diameter and pitch distance of a capillary tube. Five capillary tubes of 2 mm in diameter and 1500 mm length each are used, as same as original capillary tube of the refrigerator. The capillary tubes is formed in five shapes, each one has different coil diameter (D) namely 25, 50, 75, 100 and 125 mm in diameter, in addition three distances between each coil (pitch (P)) is tested, namely 6, 8 and 10 mm. The pressure at inlet and outlet of capillary are measured to calculate the cycle COP, as well as the power consumed by the cycle compressor is measured to calculate the mass flow rate of refrigerant. The work show that the coiled diameter of capillary tube affect the cycle COP strongly, as the capillary coiled diameter (D) increases from 25 to 100 mm the cycle COP increases from 2.8 to 3.7 when the cabinet temperature equals to 8oC. The increases of coiled diameter more than 100 mm shows insignificant effect on the cycle COP. While the pitch space of capillary tube coiled shows minor effect on the cycle COP. Moreover, to the mass flow rate of refrigerant increases with approximately ranges from 1.2−2.7


Sign in / Sign up

Export Citation Format

Share Document