scholarly journals Scaling of Vertical Component of Seismic Ground Motion

2020 ◽  
Vol 59 (5) ◽  
pp. 3827-3845
Author(s):  
Fikrat ALMahdi ◽  
Yasin Fahjan ◽  
Adem Dogˇangün
2020 ◽  
Vol 110 (2) ◽  
pp. 471-488 ◽  
Author(s):  
Samantha M. Palmer ◽  
Gail M. Atkinson

ABSTRACT Spectral decay of ground-motion amplitudes at high frequencies is primarily influenced by two parameters: site-related kappa (κ0) and regional Q (quality factor, inversely proportional to anelastic attenuation). We examine kappa and apparent Q-values (Qa) for M≥3.5 earthquakes recorded at seismograph stations on rock sites in eastern and western Canada. Our database contains 20 earthquakes recorded on nine stations in eastern Canada and 404 earthquakes recorded on eight stations in western Canada, resulting in 105 and 865 Fourier amplitude spectra, respectively. We apply two different methods: (1) a modified version of the classical S-wave acceleration method; and (2) a new stacking method that is consistent with the use of kappa in ground-motion modeling. The results are robust with respect to the method used and also with respect to the frequency band selected, which ranges from 9 to 38 Hz depending on the region, event, and method. Kappa values obtained from the classical method are consistent with those of the stacked method, but the stacked method provides a lower uncertainty. A general observation is that kappa is usually larger, and apparent Q is smaller, for the horizontal component in comparison to the vertical component. We determine an average regional κ0=7  ms (horizontal) and 0 ms (vertical) for rock sites in eastern Canada; we obtain κ0=19  ms (horizontal) and 14 ms (vertical) for rock sites in western Canada. We note that kappa measurements are quite sensitive to details of data selection criteria and methodology, and may be significantly influenced by site effects, resulting in large site-to-site variability.


2011 ◽  
Vol 255-260 ◽  
pp. 2341-2344
Author(s):  
Mohammad Saeed Masoomi ◽  
Siti Aminah Osman ◽  
Ali Jahanshahi

This paper presents the performance of base-isolated steel structures under the seismic load. The main goals of this study are to evaluate the effectiveness of base isolation systems for steel structures against earthquake loads; to verify the modal analysis of steel frame compared with the hand calculation results; and development of a simulating method for base-isolated structure’s responses. Two models were considered in this study, one a steel structure with base-isolated and the other without base-isolated system. The nonlinear time-history analysis of both structures under El Centro 1940 seismic ground motion was used based on finite element method through SAP2000. The mentioned frames were analyzed by Eigenvalue method for linear analysis and Ritz-vector method for nonlinear analysis. Simulation results were presented as time-acceleration graphs for each story, period and frequency of both structures for the first three modes.


2015 ◽  
Vol 31 (3) ◽  
pp. 1629-1645 ◽  
Author(s):  
Ronnie Kamai ◽  
Norman Abrahamson

We evaluate how much of the fling effect is removed from the NGA database and accompanying GMPEs due to standard strong motion processing. The analysis uses a large set of finite-fault simulations, processed with four different high-pass filter corners, representing the distribution within the PEER ground motion database. The effects of processing on the average horizontal component, the vertical component, and peak ground motion values are evaluated by taking the ratio between unprocessed and processed values. The results show that PGA, PGV, and other spectral values are not significantly affected by processing, partly thanks to the maximum period constraint used when developing the NGA GMPEs, but that the bias in peak ground displacement should not be ignored.


1990 ◽  
Vol 116 (11) ◽  
pp. 2381-2399 ◽  
Author(s):  
George Deodatis ◽  
Masanobu Shinozuka ◽  
Apostolos Papageorgiou

Sign in / Sign up

Export Citation Format

Share Document