A novel low-temperature absorption–compression cascade refrigeration system

2015 ◽  
Vol 75 ◽  
pp. 504-512 ◽  
Author(s):  
Yingjie Xu ◽  
FuSheng Chen ◽  
Qin Wang ◽  
Xiaohong Han ◽  
Dahong Li ◽  
...  
Author(s):  
Hendri ◽  
Roswati Nurhasanah ◽  
Prayudi ◽  
Suhengki

Low temperature storage with a single refrigeration system only stable up to 228 K temperature. The purpose of this study is to develop a low temperature cool storage with cascade refrigeration system, with hydrocarbon refrigerants in terms of energy and exergy analysis. Experimental research in laboratories using refrigerant hydrocarbon MC22 and MC134 on the hight temperature circuit, and R404A and R502 using on low temperature circuit. Condenser heat exchanger using a type of exchanger plate. Resulting from this research, obtained that result the MC22/R404A, MC22/R502 and MC134/R404A refrigerant pair can reach a temperature of 220 K. The MC22/R404A refrigerant pair has god performance, COP, total loss exergy, and exergy efficiency is better than MC22/R502, and MC134/R04A refrigerant pairs.


2011 ◽  
Vol 19 (03) ◽  
pp. 203-212 ◽  
Author(s):  
DUSHYANTHA GUNAWARDANE ◽  
PRADEEP BANSAL

This paper presents a mathematical model for the evaporator of a cascade refrigeration system, operating down to -40°C. The system uses Carbon dioxide (R744) and Propylene (R1270), respectively, as the low temperature and high temperature cycle refrigerant. The model is developed in Engineering Equation Solver software package following the elemental Number of Transfer Units-effectiveness method, where frost has not been considered. The evaporator is a cross-flow finned tube serpentine heat exchanger, which was divided into numerous elements along the flow path of the refrigerant. The inputs to the model include inlet temperatures and mass flow rates of both the streams along with the heat flux, while the main outputs are the outlet temperatures, refrigeration capacity and HX effectiveness. The model is found to underpredict the refrigeration capacity by about 10% when compared with experimental data.


2013 ◽  
Vol 388 ◽  
pp. 96-100
Author(s):  
Nasruddin ◽  
M. Idrus Alhamid ◽  
Darwin R.B. Syaka ◽  
Arnas

Medicine and biomedical research activities require cold storage to store biomedical specimens such as, for example, stem cell, sperm, blood and other organs. During storage, to prevent the specimen from damage required a special cold storage reaches -80°C [1]. Using single cycle refrigeration machine can only reach -40°C, and performance deteriorates below -35°C drop in pressure associated with evaporation. Thus, to reach lower temperatures, use cascade refrigeration machine [2]. During this low-temperature circuit cascade refrigeration systems still use refrigerants that contain ozone-depleting or global warming (CFCs and HCFCs). To overcome this, a mixture of carbon dioxide and ethane azeotropic a promising alternative refrigerants. Simulation studies and experiments indicate a mixture of carbon dioxide and ethane were able to achieve the minimum temperature to -80°C [4-7]. With the mass ratio 70% R170 and 30% R744 circuit at low temperature refrigeration systems and uses a capillary tube expansion device 0.054 inch diameter with a length of 6 meters and 3 meters then use an electric heater as the cooling load. Cooling load is given by the variation of 90 W, 120 W and 150 W at a cabin in the low temperature circuit. From the experiment will be known characteristics of cascade refrigeration system with refrigerant mixture and will get the parameter data to make cascade refrigeration machine.


2012 ◽  
Vol 20 (03) ◽  
pp. 1250010 ◽  
Author(s):  
ANTONIO MESSINEO ◽  
DOMENICO PANNO

Due to the negative effects of synthetic refrigerants on the environment, natural refrigerants have obtained again interest as alternative refrigerants for different applications because of their zero ODP and negligible GWP. This paper presents a thermodynamic analysis of different two-stage cascade refrigeration systems using as refrigerant carbon dioxide (R744) in low-temperature circuit, and, respectively, ammonia (R717), propane (R290), butane (R600), R404A, R410A and R134a in high-temperature circuit. The operating parameters considered in this study include condensing and evaporating temperatures in high-temperature circuit, temperature difference in the cascade heat exchanger, and evaporating and condensing temperatures in the low-temperature circuit. The results obtained show that a cascade refrigeration system using natural refrigerants is an interesting alternative to systems using synthetic refrigerants for energetic, security and environmental reasons.