Modified two-temperature calibration method for emissivity measurements at high temperatures

2020 ◽  
Vol 168 ◽  
pp. 114854
Author(s):  
Kaihua Zhang ◽  
Yufang Liu
2020 ◽  
Vol 87 (3) ◽  
pp. 153-163
Author(s):  
Caroline Schultealbert ◽  
Robin Diener ◽  
Johannes Amann ◽  
Tobias Baur ◽  
Andreas Schütze ◽  
...  

AbstractIn this work a novel calibration method for micro hotplates is developed and tested. The method is based on phase change processes of applied testing materials, which can be identified due to their phase change enthalpy in the power needed for the hotplate to linearly heat up. For traceability and reproducibility tests a ceramic heating element (Umweltsensortechnik GmbH, Geschwenda, Germany) including a Pt100 sensing element was used. Using the melting process of Hexatriacontane and different temperature ramps the feasibility of the method was tested, and the onset point of the phase change was identified as the best feature for temperature calibration. On this substrate we achieved an absolute deviation of 5 °C to literature values and a relative uncertainty of 0.3 °C. Pyrazine, which can be removed more easily, showed an absolute deviation of 2.5 °C to literature values and a relative uncertainty of again 0.3 °C for temperature calibration. The sublimation process of Hexamethylenetetramine was also tested but did not yield stable results. The two materials successfully tested on the ceramic heater were then transferred to MEMS membrane heaters (AS-MLV-P2 and AS-MLV, both metal oxide semiconductor gas sensors, ams AG, Premstätten, Austria) showing the applicability of the method for MEMS device calibration and yielding relative uncertainties for the calibrated heater resistance of 0.17 Ω (corresponding to 0.39 °C). For Hexatriacontane on the ceramic hotplate we also show the possibility of mass quantification through evaluating the phase change enthalpy.


2010 ◽  
Vol 44-47 ◽  
pp. 2774-2777
Author(s):  
Le Chen ◽  
Xiao Li Zhang ◽  
Yan Song

Based on the principle of the distributed optical fiber temperature sensor, the research with temperature calibration technique for temperature measurement precision of system was studied in this paper. Accurate temperature was gotten by standards of environmental temperature thermometer, with different temperature calibration methods to solve the accuracy problem of the distributed optical fiber temperature sensor.


2016 ◽  
Author(s):  
Peng Chen ◽  
Zhihua Mao ◽  
Haiqing Huang ◽  
Yan Bai ◽  
Tianyu Wang

2015 ◽  
Vol 22 (1) ◽  
pp. 626-634 ◽  
Author(s):  
J. Chen ◽  
K. Pitchai ◽  
S. Birla ◽  
D. Jones ◽  
J. Subbiah ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document