Exergoeconomic analysis and optimization of solar assisted hybrid cooling systems in full working conditions

Author(s):  
Junquan Zeng ◽  
Zeyu Li ◽  
Zeyu Peng
2021 ◽  
Vol 238 ◽  
pp. 114134
Author(s):  
Mohamed G. Gado ◽  
Tamer F. Megahed ◽  
Shinichi Ookawara ◽  
Sameh Nada ◽  
Ibrahim I. El-Sharkawy

Author(s):  
Tianyi Gao ◽  
James Geer ◽  
Bahgat G. Sammakia ◽  
Russell Tipton ◽  
Mark Seymour

Cooling power constitutes a large portion of the total electrical power consumption in data centers. Approximately 25%∼40% of the electricity used within a production data center is consumed by the cooling system. Improving the cooling energy efficiency has attracted a great deal of research attention. Many strategies have been proposed for cutting the data center energy costs. One of the effective strategies for increasing the cooling efficiency is using dynamic thermal management. Another effective strategy is placing cooling devices (heat exchangers) closer to the source of heat. This is the basic design principle of many hybrid cooling systems and liquid cooling systems for data centers. Dynamic thermal management of data centers is a huge challenge, due to the fact that data centers are operated under complex dynamic conditions, even during normal operating conditions. In addition, hybrid cooling systems for data centers introduce additional localized cooling devices, such as in row cooling units and overhead coolers, which significantly increase the complexity of dynamic thermal management. Therefore, it is of paramount importance to characterize the dynamic responses of data centers under variations from different cooling units, such as cooling air flow rate variations. In this study, a detailed computational analysis of an in row cooler based hybrid cooled data center is conducted using a commercially available computational fluid dynamics (CFD) code. A representative CFD model for a raised floor data center with cold aisle-hot aisle arrangement fashion is developed. The hybrid cooling system is designed using perimeter CRAH units and localized in row cooling units. The CRAH unit supplies centralized cooling air to the under floor plenum, and the cooling air enters the cold aisle through perforated tiles. The in row cooling unit is located on the raised floor between the server racks. It supplies the cooling air directly to the cold aisle, and intakes hot air from the back of the racks (hot aisle). Therefore, two different cooling air sources are supplied to the cold aisle, but the ways they are delivered to the cold aisle are different. Several modeling cases are designed to study the transient effects of variations in the flow rates of the two cooling air sources. The server power and the cooling air flow variation combination scenarios are also modeled and studied. The detailed impacts of each modeling case on the rack inlet air temperature and cold aisle air flow distribution are studied. The results presented in this work provide an understanding of the effects of air flow variations on the thermal performance of data centers. The results and corresponding analysis is used for improving the running efficiency of this type of raised floor hybrid data centers using CRAH and IRC units.


2018 ◽  
Author(s):  
Waleed El-Damaty ◽  
Mohamed Gadalla

For many years, thermodynamic analysis was considered to be the principal tool that is used to predict the performance of a power plant. Recently, the environmental effect and the cost of power plants have been considered as important as the thermodynamic performance in design of power plants. Thus, researchers started to adopt a relevantly new approach called the exergoeconomic analysis which combines the thermodynamic technicalities as well as the economic analysis to design power plants. The exergoeconomic analysis provides crucial information that helps in foreseeing not only the thermodynamic performance but also all economic variables related to power plants. Increasing the efficiency of the power plant has been the major concern in power plants. Thus, the global approach of reaching high turbine inlet temperatures to improve the efficiency of power plants, has exposed the turbine blades to some serious problems. Thereby, cooling the turbine blades has become an important aspect that needs to be taken care of during the power plant operation. In this paper, a cooled gas turbine with intercooler, recuperator and reheater is adopted where it is incorporated with a cooling system. An exergoeconomic analysis accompanied by a sensitivity analysis was performed on the gas turbine cycle to determine the exergo-economic factor and the relative cost difference in addition to study the effect of different variables on the gas turbine thermal and exergetic efficiency, net specific work and the total cost rate. Average cost theory approach was adopted from various thermo-economic methodologies to determine the cost calculation during this investigation. The results showed a reduction in the total coolant mass flow rate in the base case where no cooling systems are integrated from 3.349 kg/s to 3.01 kg/s, 2.995 kg/s and 2.977 kg/s in the case of integrating the cooling systems triple stage Maisotsenko desiccant, triple stage precooling Maisotsenko desiccant and triple stage extra cooling Maisotsenko desiccant, respectively. Accordingly, the thermal efficiency has increased to reach 52.69%, 52.89% and 53.12% by the integration of TS-MD, TS-PMD and TS-EMD cooling systems, respectively.


Author(s):  
John S. Maulbetsch

Water use by power plant cooling systems has become a critical siting issue for new plants and the object of increasing pressure for modification or retrofit at existing plants. Wet cooling typically costs less and results in more efficient plant performance. Dry cooling, while costing more and imposing heat rate and capacity penalties on the plant, conserves significant amounts of water and eliminates any concerns regarding thermal discharge to or intake losses on local water bodies. Hybrid cooling systems have the potential of combining the advantages of both systems by reducing, although not eliminating, water requirements while incurring performance penalties that are less than those from all-dry systems. The costs, while greater than those for wet cooling, can be less than those for dry. This paper addresses parallel wet/dry systems combining direct dry cooling using a forced-draft air-cooled condenser (ACC) with closed-cycle wet cooling using a surface (shell-and-tube) steam condenser and a mechanical-draft, counterflow wet cooling tower as applied to coal-fired steam plants, gas-fired combined-cycle plants and nuclear plants. A brief summary of criteria used to identify situations where hybrid systems should be considered is given. A methodology for specifying and selecting a hybrid system is described along with the information and data requirements for sizing and estimating the capital costs and water requirements a specified plant at a specified site. The methodology incorporates critical plant and operating parameters into the analysis, such as plant monthly load profile, plant equipment design parameters for equipment related to the cooling system, e.g. steam turbine, condenser, wet or dry cooling system, wastewater treatment system. Site characteristics include a water budget or constraints, e.g. acre feet of water available for cooling on an annual basis as well as any monthly or seasonal “draw rate” constraints and meteorological data. The effect of economic parameters including cost of capital, power, water and chemicals for wastewater treating are reviewed. Finally some examples of selected systems at sites of varying meteorological characteristics are presented.


Author(s):  
Abdul Ahad Iqbal ◽  
Ali Al-Alili

Abstract The performance of air conditioning systems is highly dependent on the environmental conditions of the high pressure side, where heat is rejected to the environment. Air conditioning systems utilize dry cooling systems which often don’t provide adequate cooling during peak cooling periods, or wet cooling systems which consume a lot of water. In this study, a novel hybrid cooling system that can provide both wet and dry cooling was modelled in TRNSYS, and used to provide cooling to closed sorption air conditioning systems. The performance of these systems with the hybrid cooling system was compared to the performance of a standard vapor compression cooling system being cooled by a dry cooling system. The COPsol of the vapor compression cooling system exhibited a decrease of almost 26% during the summer period, whereas the COPsol of the sorption systems increased by around 30%. Similarly, the cooling capacity of the vapor compression cooling system dropped by almost 5%, and for the sorption systems, it increased by around 20% during the summer period.


Author(s):  
R. W. Card

A hybrid wet-dry cooling system can be designed for a large combined-cycle power plant. A well-designed hybrid cooling system will provide reasonable net generation year-round, while using substantially less water than a conventional wet cooling tower. The optimum design for the hybrid system depends upon climate at the site, the price of power, and the price of water. These factors vary on a seasonal basis. Two hypothetical power plants are modeled, using state-of-the-art steam turbines and hybrid cooling systems. The plants are designed for water-constrained sites incorporating typical weather data, power prices, and water prices. The principles for economic designs of hybrid cooling systems are demonstrated.


2021 ◽  
Author(s):  
Nicola Rosafio ◽  
Simone Salvadori ◽  
Daniela Anna Misul ◽  
Mirko Baratta ◽  
Mauro Carnevale ◽  
...  

Abstract Advanced film-cooling systems are necessary to guarantee safe working conditions of high-pressure turbine stages. A fair prediction of the inherent unsteady interaction between the main-flow and the jet of cooling air allows for correctly describing the complex flow structures arising close to the cooled region. This proves to be crucial for the design of high-performance cooling systems. Results obtained by means of an experimental campaign performed at the University of Karlsruhe are shown along with unsteady numerical data obtained for the corresponding working conditions. The experimental rig consists of an instrumented plate where the hot flow reaches Mach = 0.6 close to the coolant jet exit section. The numerical campaign models the unsteady film cooling characteristics using a third-order accurate method. The ANSYS® FLUENT® software is used along with a mesh refinement procedure that allows for accurately modelling the flow field. Turbulence is modelled using the k-ω SST model. Time-averaged and time-resolved distributions of adiabatic effectiveness and Net Heat Flux Reduction are analysed to determine to what extent deterministic unsteadiness plays a role in cooling systems. It is found that coolant pulsates due to fluctuations generated by flow separation at the inlet section of the cooling channel. Visualizations of the fluctuating flow field demonstrate that coolant penetration depends on the phase of the pulsation, thus leading to periodically reduced shielding. Eventually, unsteadiness occurring at integral length scales does not provide enough mixing to match the experiments, thus hinting that the dominant phenomena occur at inertial length scales.


Energy ◽  
2014 ◽  
Vol 66 ◽  
pp. 711-721 ◽  
Author(s):  
Christopher Horvath ◽  
Yunho Hwang ◽  
Reinhard Radermacher ◽  
William Gerstler ◽  
Ching-Jen Tang